4 Technical Description4.5 Options4.5.1 Display and Operating Unit Type 657 R 0831Fig. 4-5 Optional with LT2 in wall-mounting housing type 657 R 1025optional with mounting plate type 657 R 1030at LT2 type 657 R 1040 included as a standard for panel installationsee separate publication DLT 606023

4 Technical Description4.5.2 Remote-display-softwarePC-software to configure the LT2. Use it instead of the display and operating unit, and to storeand restore the data set.Remote-Display-Software including interface module RS 232 for PC type 657 R 1101Other licences for the remote-display-software type 657 R 1102For windows-based computers, connection with LT2 via RS 232 interface.Refer to special documentation DLT1004.Suitable for all PCs with RS 232 or RS 422 interface from Windows 95, Windows NT (32-bitversion) onwardFor details see separate publication DLT 10044.5.3 Calculation of Combustion Efficiency Type 657 R 0895 / R 0896The calculation follows the formula:n F = 100 (q Af + q Ag )%q Af = Exhaust gas loss through free heatq Ag = Exhaust gas loss through bounded heatq Af = (t A - t L ) * [A 2 /21 - O 2 + B]Calculation of exhaust gas losses is based on the following mean fuel values:OilGasA 2 = 0.68;A 2 = 0.66;It is assumed that the combustion is CO- and soot-free.Exhaust gas losses through bound heat are not taken into account.Display:EfficiencyExhaust gas lossesExhaust gas temperatureIntake air temperatureOther ranges on requestB = 0.007B = 0.0090...100%0...100%0...320°C0...320°C24

4 Technical Description4.5.2 Remote-display-softwarePC-software to configure the <strong>LT2</strong>. Use it instead of the display and operating unit, and to storeand restore the data set.Remote-Display-Software including interface module RS 232 <strong>for</strong> PC type 657 R 1101Other licences <strong>for</strong> the remote-display-software type 657 R 1102For windows-based computers, connection with <strong>LT2</strong> via RS 232 interface.Refer to special documentation DLT1004.Suitable <strong>for</strong> all PCs with RS 232 or RS 422 interface from Windows 95, Windows NT (32-bitversion) onwardFor details see separate publication DLT 10044.5.3 Calculation of Combustion Efficiency Type 657 R 0895 / R 0896The calculation follows the <strong>for</strong>mula:n F = 100 (q Af + q Ag )%q Af = Exhaust gas loss through free heatq Ag = Exhaust gas loss through bounded heatq Af = (t A - t L ) * [A 2 /21 - O 2 + B]Calculation of exhaust gas losses is based on the following mean fuel values:OilGasA 2 = 0.68;A 2 = 0.66;It is assumed that the combustion is CO- and soot-free.Exhaust gas losses through bound heat are not taken into account.Display:EfficiencyExhaust gas lossesExhaust gas temperatureIntake air temperatureOther ranges on requestB = 0.007B = 0.0090...100%0...100%0...320°C0...320°C24

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!