Quick Reference for End-Users Lambda Transmitter LT2 ... - lamtec
Quick Reference for End-Users Lambda Transmitter LT2 ... - lamtec Quick Reference for End-Users Lambda Transmitter LT2 ... - lamtec
4 Technical Description4.5 Options4.5.1 Display and Operating Unit Type 657 R 0831Fig. 4-5 Optional with LT2 in wall-mounting housing type 657 R 1025optional with mounting plate type 657 R 1030at LT2 type 657 R 1040 included as a standard for panel installationsee separate publication DLT 606023
4 Technical Description4.5.2 Remote-display-softwarePC-software to configure the LT2. Use it instead of the display and operating unit, and to storeand restore the data set.Remote-Display-Software including interface module RS 232 for PC type 657 R 1101Other licences for the remote-display-software type 657 R 1102For windows-based computers, connection with LT2 via RS 232 interface.Refer to special documentation DLT1004.Suitable for all PCs with RS 232 or RS 422 interface from Windows 95, Windows NT (32-bitversion) onwardFor details see separate publication DLT 10044.5.3 Calculation of Combustion Efficiency Type 657 R 0895 / R 0896The calculation follows the formula:n F = 100 (q Af + q Ag )%q Af = Exhaust gas loss through free heatq Ag = Exhaust gas loss through bounded heatq Af = (t A - t L ) * [A 2 /21 - O 2 + B]Calculation of exhaust gas losses is based on the following mean fuel values:OilGasA 2 = 0.68;A 2 = 0.66;It is assumed that the combustion is CO- and soot-free.Exhaust gas losses through bound heat are not taken into account.Display:EfficiencyExhaust gas lossesExhaust gas temperatureIntake air temperatureOther ranges on requestB = 0.007B = 0.0090...100%0...100%0...320°C0...320°C24
- Page 1: Quick Reference for End-UsersLambda
- Page 4 and 5: Table of Contents5.3 Wiring Example
- Page 6 and 7: 1 General Information1 General Info
- Page 8 and 9: 2 Safety2.2 For Your Safety2.2.1 Ex
- Page 10 and 11: 2 SafetyUser groupsTwo user groups
- Page 12 and 13: 3 Overview3 Overview3.1 System Over
- Page 14 and 15: 3 Overview3.2 Brief DescriptionUniv
- Page 16 and 17: 4 Technical Description10 LT2 Lambd
- Page 18 and 19: 4 Technical Description4.2.2 Probe
- Page 20 and 21: 4 Technical Description3: Displaya0
- Page 22 and 23: 4 Technical Description12: Analogue
- Page 26 and 27: 4 Technical DescriptionMeasurement
- Page 28 and 29: 4 Technical DescriptionDigital outp
- Page 30 and 31: 5 LAMTEC SYSTEM BUS (LSB)5 LAMTEC S
- Page 32 and 33: 6 Commissioning / Shutdown6 Commiss
- Page 34 and 35: 6 Commissioning / Shutdown6.2.3 Int
- Page 36 and 37: 6 Commissioning / ShutdownNOTICE!Re
- Page 38 and 39: 7 Operation7 Operation7.1 Operation
- Page 40 and 41: 7 Operation7.2.3 Liquid Purificatio
- Page 42 and 43: 8 Service and MaintenanceCAUTION!Do
- Page 44 and 45: 9 Faults / Warnings9 Faults / Warni
- Page 46 and 47: 9 Faults / Warnings9.3.1 Faults - C
- Page 48 and 49: 9 Faults / Warnings9.4.2 Offset Vol
- Page 50 and 51: 11 Appendix11 Appendix11.1 Technica
- Page 52 and 53: 11 AppendixTechnical Data Lambda Tr
- Page 54 and 55: 11 Appendix11.3 Electric Connection
- Page 56 and 57: 11 Appendix11.4 Wet/Dry Measurement
- Page 58 and 59: 12 Declaration of Conformity12 Decl
- Page 60: 12 Declaration of Conformity59
4 Technical Description4.5.2 Remote-display-softwarePC-software to configure the <strong>LT2</strong>. Use it instead of the display and operating unit, and to storeand restore the data set.Remote-Display-Software including interface module RS 232 <strong>for</strong> PC type 657 R 1101Other licences <strong>for</strong> the remote-display-software type 657 R 1102For windows-based computers, connection with <strong>LT2</strong> via RS 232 interface.Refer to special documentation DLT1004.Suitable <strong>for</strong> all PCs with RS 232 or RS 422 interface from Windows 95, Windows NT (32-bitversion) onwardFor details see separate publication DLT 10044.5.3 Calculation of Combustion Efficiency Type 657 R 0895 / R 0896The calculation follows the <strong>for</strong>mula:n F = 100 (q Af + q Ag )%q Af = Exhaust gas loss through free heatq Ag = Exhaust gas loss through bounded heatq Af = (t A - t L ) * [A 2 /21 - O 2 + B]Calculation of exhaust gas losses is based on the following mean fuel values:OilGasA 2 = 0.68;A 2 = 0.66;It is assumed that the combustion is CO- and soot-free.Exhaust gas losses through bound heat are not taken into account.Display:EfficiencyExhaust gas lossesExhaust gas temperatureIntake air temperatureOther ranges on requestB = 0.007B = 0.0090...100%0...100%0...320°C0...320°C24