Quick Reference for End-Users Lambda Transmitter LT2 ... - lamtec

Quick Reference for End-Users Lambda Transmitter LT2 ... - lamtec Quick Reference for End-Users Lambda Transmitter LT2 ... - lamtec

12.07.2015 Views

4 Technical Description10 LT2 Lambda Transmitter panel installation3 HE, 50 TE 173 x 310 x 280 mm (h x w x d)type 657 R 104011 LT2 Lambda Transmitter in IP 54 wall-mounted housing type 657 R 1025,sheet steel, 400 x 300 x 150 mm (h x w x d) with display and operating unit13 LT2 Lambda Transmitter on mounting plate350x258x132 (HxBxT) type 657 R 10304.1.1 Advantages of the Measurement Principle• No gas treatment needed, measurement directly in the humid flue gas• Setting time at 90%-value (T 90 ) < 20 seconds• measuring gas temperature up to 300 °C• low heating power 15...25 Wattdepending on the state of aging of the zirconium dioxid sensor• universal applycable• easy application• low-maintenance15

4 Technical Description4.2 LT2 Lambda Transmitter4.2.1 LT2 Lambda Transmitter in Wall Mounting Case1 Display and operating unit2 Probe and electronics transformer3 Connection for Remote-Display-Software (Option)4 Connecting cable with plug for display and operating unit5 Electrical connections6 BUS-interface alternative LAMTEC SYSTEM BUS (CAN BUS)7 Operating mode display multifunction push button maintenance switch8 Protective earth terminal for cable screening9 Monitor output10 Mains connection (plug)11 Terminal bar x 212 Relay module type 660 R 0017Fig. 4-1 LT2 Lambda Transmitter in wall-mounting housing type 657 R 1025 with displayand operating unit type 657 R 0831Accessible after removing the front panel with the mainswitch ("POWER”)Fig. 4-2 Change over power supply voltage16

4 Technical Description4.2 <strong>LT2</strong> <strong>Lambda</strong> <strong>Transmitter</strong>4.2.1 <strong>LT2</strong> <strong>Lambda</strong> <strong>Transmitter</strong> in Wall Mounting Case1 Display and operating unit2 Probe and electronics trans<strong>for</strong>mer3 Connection <strong>for</strong> Remote-Display-Software (Option)4 Connecting cable with plug <strong>for</strong> display and operating unit5 Electrical connections6 BUS-interface alternative LAMTEC SYSTEM BUS (CAN BUS)7 Operating mode display multifunction push button maintenance switch8 Protective earth terminal <strong>for</strong> cable screening9 Monitor output10 Mains connection (plug)11 Terminal bar x 212 Relay module type 660 R 0017Fig. 4-1 <strong>LT2</strong> <strong>Lambda</strong> <strong>Transmitter</strong> in wall-mounting housing type 657 R 1025 with displayand operating unit type 657 R 0831Accessible after removing the front panel with the mainswitch ("POWER”)Fig. 4-2 Change over power supply voltage16

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!