Xs plate<strong>Plates</strong> <strong>for</strong><strong>arthrodesis</strong>SETO S T E O S Y S T E M


DescriptionXS Plate ® is a system of several sizes of titanium TA6V ELI plates <strong>for</strong> foot surgery <strong>arthrodesis</strong>.These plates are made ofinserts, a material whose radiotransparency enables optimum x-ray monitoring.Its mechanical characteristics are comparable with those of bone.Inserts made ofPE1206016-holes plate2.1mm thickness.PE1205015-holes plate2.1mm thickness.PE1202032-holes plate2.1mm thickness29 mm interaxis.PE1202022-holes plate2.1mm thickness19 mm interaxis.PE1202012-holes plate2.1mm thickness9 mm interaxis.An easy and efficientoperating techniqueNo additional operating time and at the end,a locked unit, cast in one piece, a hallmark ofperfect primary stability.EASYLOCK screwVENPS24(xx)The bending of the plates must be carriedout between two consecutive holes.SCREWVENPS 24VES 24VENP 24VE 24Sterile Non-sterile Cannulated Non-cannulated ØLength.Material•• 2.4 mm 10 to 28 mm (from 2 in 2 mm).• •2.4 mm 10 to 28 mm (from 2 in 2 mm).• 2.4 mm 10 to 28 mm (from 2 in 2 mm).• •2.4 mm 10 to 28 mm (from 2 in 2 mm).Titanium TA6V ELI / ISO 5832-3Titanium TA6V ELI / ISO 5832-3Titanium TA6V ELI / ISO 5832-3Titanium TA6V ELI / ISO 5832-3O S T E O S Y S T E MThe Easylock® system means you can choose the angle of thescrew within a +/-10° range to the perpendicular axis of the cupsurface.elasticity, which is close to that of bone, givesthe unit dynamic properties and the necessary angular stability<strong>for</strong> the consolidation process.


Surgical techniquemetatarsophalangeal <strong>arthrodesis</strong>1Exostosectomy ...2... And transversal metatarsal and phalangeal cut.3 4Temporary stabilization using two pins 0.80mm…and checking ofsupport of the position of the phalanx in slight valgus (10-20°).<strong>Plates</strong> stabilization using Ø 0.80mm pins.5Choice of angle <strong>for</strong> screws and drilling.6Measuring screw length.7Screwing the implant and locking the conicalthreaded head in the PEEK insert.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!