<strong>OPTIFLEX</strong> <strong>1300</strong> CTECHNICAL DATA 5Resolution ±3 µATemperature driftTypically 50 ppm/KError signal High: 22 mA; Low: 3.6 mA acc. to NAMUR NE 43PROFIBUS PATypeFunction blocksProtocol / CommunicationstandardPhysical layer typesOther featuresDevice power supply (24 V input)Current consumption onPROFIBUS networkOutput data4-wire (+ local HART) level transmitter; Time Domain Reflectometry (TDR)11 (level, distance, interface level, interface distance, layer, interface conversion,ullage conversion, layer conversion, level conversion, level mass and distancemass)PROFIBUS PA protocol that agrees with IEC 61158-2, galvanically isolatedStandard power signaling, bus powered, non I.S.Bus interface with integrated reverse polarity protection18...30 VDC20 mA<strong>Level</strong>, distance, interface level, interface distance, layer, interface conversion,ullage conversion, layer conversion, level conversion, level mass and distance massNoneTypically 0 mA (FDE =Fault Disconnection Electronic)Input dataError current FDEAddress range 0...125. Default address: 126.FOUNDATION FieldbusType4-wire (+ local HART) level transmitter; Time Domain Reflectometry (TDR)Function blocks1 × Resource Block (RB), 4 × Analog Input Blocks (AI), 1 × Transducer Block (TB)Analog Input Block: 50 msProtocol / Communication Foundation Fieldbus protocol that agrees with IEC 61158-2, galvanically isolatedstandardITK version 5.1Physical layer typesStandard power signaling, bus powered, non I.S.Other featuresBus interface with integrated reverse polarity protectionDevice power supply (24 V input) 18...30 VDCBus power supply9...32 VDC (non-Ex); 9...17.5 VDC (intrinsically-safe)Basic current20 mAMaximum error current20 mAStart current after 10 ms 20 mAPolar sensitivityYesMinimum cycle time100 msOutput data<strong>Level</strong>, distance, level conversion, interface level, interface distance, layer, interfaceconversion, ullage conversion, layer conversion, level conversion, level mass ordistance massInput dataNoneError current FDETypically 0 mA (FDE =Fault Disconnection Electronic)Link Master functionNot supported09/2010 - 4000049805 - QS <strong>OPTIFLEX</strong> <strong>1300</strong> R08 enwww.krohne.com41

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!