5 TECHNICAL DATAOPTIFLEX 1300 CProcess connectionsThreadSingle cable Ø2 mm / 0.08¨Single cable Ø8 mm / 0.3¨All other probesG ½; ½ NPT; ½ NPTF (for the HT/HP version)G1½; 1½ NPTG ¾…1½; ¾…1½ NPTFlange versions for single cable Ø8 mm / 0.3¨, , double rod and double cable probesENASMEJISDN40…150 in PN16, PN40, PN63 or PN100; others on request1½¨…8¨ in 150 lb, 1½¨...6¨ in 300 lb, 1½¨...4¨ in 600 lb or 900 lb; 1½¨...2¨ in 1500 lb;others on request40…100A in 10K; others on requestFlange versions for single cable Ø2 mm / 0.08¨ probeENASMEJISFlange versions for all other probesENASMEJISOther options for single and double rod probesSMSTri-clampOthersElectrical connectionsDN25…150 in PN16, PN40, PN63 or PN100; others on request1¨…8¨ in 150 lb, 1½¨...6¨ in 300 lb, 1¨...4¨ in 600 lb or 900 lb, 1¨...2¨ in 1500 lb, 1¨ in2500 lb; others on request40…100A in 10K; others on requestDN25…150 in PN16, PN40, PN63 or PN100; others on request1¨…8¨ in 150 lb, 1½¨...6¨ in 300 lb, 1¨...4¨ in 600 lb or 900 lb, 1¨...2¨ in 1500 lb; otherson request40…100A in 10K; others on requestAvailable on requestAvailable on requestOthers on requestPower supply Terminals output 1 - Non-Ex / Ex i:14…30 VDC; min./max. value for an output of 22 mA at the terminalTerminals output 1 - Ex d:20…36 VDC; min./max. value for an output of 22 mA at the terminalTerminals output 2 - Non-Ex / Ex i / Ex d:10…30 VDC; min/max. value for an output of 22 mA at the terminal (additionalpower supply needed - output only)Cable entryM20×1.5; ½ NPTG ½ (not for FM- and CSA-approved devices. Not for stainless steel housings.)M25×1.5 (for stainless steel housings only)Cable glandStandard: noneOptions: M20×1.5 (for non-Ex and Ex-approved devices with M20×1.5 and M25×1.5cable entries); others are available on requestCable entry capacity (terminal) 0.5…1.5 mm²Input and outputCurrent outputOutput signal (Output 1) 4…20 mA HART ® or 3.8…20.5 mA acc. to NAMUR NE 43 5Output signal (Output 2 -optional)4…20 mA (no HART ® signal) or 3.8…20.5 mA acc. to NAMUR NE 43 (optional)40www.krohne.com09/2010 - 4000049805 - QS OPTIFLEX 1300 R08 en
OPTIFLEX 1300 CTECHNICAL DATA 5Resolution ±3 µATemperature driftTypically 50 ppm/KError signal High: 22 mA; Low: 3.6 mA acc. to NAMUR NE 43PROFIBUS PATypeFunction blocksProtocol / CommunicationstandardPhysical layer typesOther featuresDevice power supply (24 V input)Current consumption onPROFIBUS networkOutput data4-wire (+ local HART) level transmitter; Time Domain Reflectometry (TDR)11 (level, distance, interface level, interface distance, layer, interface conversion,ullage conversion, layer conversion, level conversion, level mass and distancemass)PROFIBUS PA protocol that agrees with IEC 61158-2, galvanically isolatedStandard power signaling, bus powered, non I.S.Bus interface with integrated reverse polarity protection18...30 VDC20 mALevel, distance, interface level, interface distance, layer, interface conversion,ullage conversion, layer conversion, level conversion, level mass and distance massNoneTypically 0 mA (FDE =Fault Disconnection Electronic)Input dataError current FDEAddress range 0...125. Default address: 126.FOUNDATION FieldbusType4-wire (+ local HART) level transmitter; Time Domain Reflectometry (TDR)Function blocks1 × Resource Block (RB), 4 × Analog Input Blocks (AI), 1 × Transducer Block (TB)Analog Input Block: 50 msProtocol / Communication Foundation Fieldbus protocol that agrees with IEC 61158-2, galvanically isolatedstandardITK version 5.1Physical layer typesStandard power signaling, bus powered, non I.S.Other featuresBus interface with integrated reverse polarity protectionDevice power supply (24 V input) 18...30 VDCBus power supply9...32 VDC (non-Ex); 9...17.5 VDC (intrinsically-safe)Basic current20 mAMaximum error current20 mAStart current after 10 ms 20 mAPolar sensitivityYesMinimum cycle time100 msOutput dataLevel, distance, level conversion, interface level, interface distance, layer, interfaceconversion, ullage conversion, layer conversion, level conversion, level mass ordistance massInput dataNoneError current FDETypically 0 mA (FDE =Fault Disconnection Electronic)Link Master functionNot supported09/2010 - 4000049805 - QS OPTIFLEX 1300 R08 enwww.krohne.com41
- Page 1 and 2: OPTIFLEX 1300 C Quick StartGuided R
- Page 3 and 4: OPTIFLEX 1300 CCONTENTS4 Start-up 3
- Page 5 and 6: OPTIFLEX 1300 CINSTALLATION 22.1 In
- Page 7 and 8: OPTIFLEX 1300 CINSTALLATION 22.3 Vi
- Page 9 and 10: OPTIFLEX 1300 CINSTALLATION 22.5 Tr
- Page 11 and 12: OPTIFLEX 1300 CINSTALLATION 2Temper
- Page 13 and 14: OPTIFLEX 1300 CINSTALLATION 21 23 3
- Page 15 and 16: OPTIFLEX 1300 CINSTALLATION 2INFORM
- Page 17 and 18: OPTIFLEX 1300 CINSTALLATION 2Figure
- Page 19 and 20: OPTIFLEX 1300 CINSTALLATION 22.10.4
- Page 21 and 22: OPTIFLEX 1300 CINSTALLATION 22.10.6
- Page 23 and 24: OPTIFLEX 1300 CINSTALLATION 22.10.8
- Page 25 and 26: OPTIFLEX 1300 CINSTALLATION 2You ca
- Page 27 and 28: OPTIFLEX 1300 CINSTALLATION 22.10.1
- Page 29 and 30: OPTIFLEX 1300 CINSTALLATION 22.11 E
- Page 31 and 32: OPTIFLEX 1300 CELECTRICAL CONNECTIO
- Page 33 and 34: OPTIFLEX 1300 CSTART-UP 44.1 Start-
- Page 35 and 36: OPTIFLEX 1300 CSTART-UP 44.3.4 How
- Page 37 and 38: OPTIFLEX 1300 CTECHNICAL DATA 55.1
- Page 39: OPTIFLEX 1300 CTECHNICAL DATA 5Othe
- Page 43 and 44: OPTIFLEX 1300 CTECHNICAL DATA 55.2
5 TECHNICAL DATA<strong>OPTIFLEX</strong> <strong>1300</strong> CProcess connectionsThreadSingle cable Ø2 mm / 0.08¨Single cable Ø8 mm / 0.3¨All other probesG ½; ½ NPT; ½ NPTF (for the HT/HP version)G1½; 1½ NPTG ¾…1½; ¾…1½ NPTFlange versions for single cable Ø8 mm / 0.3¨, , double rod and double cable probesENASMEJISDN40…150 in PN16, PN40, PN63 or PN100; others on request1½¨…8¨ in 150 lb, 1½¨...6¨ in 300 lb, 1½¨...4¨ in 600 lb or 900 lb; 1½¨...2¨ in 1500 lb;others on request40…100A in 10K; others on requestFlange versions for single cable Ø2 mm / 0.08¨ probeENASMEJISFlange versions for all other probesENASMEJISOther options for single and double rod probesSMSTri-clampOthersElectrical connectionsDN25…150 in PN16, PN40, PN63 or PN100; others on request1¨…8¨ in 150 lb, 1½¨...6¨ in 300 lb, 1¨...4¨ in 600 lb or 900 lb, 1¨...2¨ in 1500 lb, 1¨ in2500 lb; others on request40…100A in 10K; others on requestDN25…150 in PN16, PN40, PN63 or PN100; others on request1¨…8¨ in 150 lb, 1½¨...6¨ in 300 lb, 1¨...4¨ in 600 lb or 900 lb, 1¨...2¨ in 1500 lb; otherson request40…100A in 10K; others on requestAvailable on requestAvailable on requestOthers on requestPower supply Terminals output 1 - Non-Ex / Ex i:14…30 VDC; min./max. value for an output of 22 mA at the terminalTerminals output 1 - Ex d:20…36 VDC; min./max. value for an output of 22 mA at the terminalTerminals output 2 - Non-Ex / Ex i / Ex d:10…30 VDC; min/max. value for an output of 22 mA at the terminal (additionalpower supply needed - output only)Cable entryM20×1.5; ½ NPTG ½ (not for FM- and CSA-approved devices. Not for stainless steel housings.)M25×1.5 (for stainless steel housings only)Cable glandStandard: noneOptions: M20×1.5 (for non-Ex and Ex-approved devices with M20×1.5 and M25×1.5cable entries); others are available on requestCable entry capacity (terminal) 0.5…1.5 mm²Input and outputCurrent outputOutput signal (Output 1) 4…20 mA HART ® or 3.8…20.5 mA acc. to NAMUR NE 43 5Output signal (Output 2 -optional)4…20 mA (no HART ® signal) or 3.8…20.5 mA acc. to NAMUR NE 43 (optional)40www.krohne.com09/2010 - 4000049805 - QS <strong>OPTIFLEX</strong> <strong>1300</strong> R08 en