12.07.2015 Views

Krohne OPTIFLEX 1300 C Level Meter Quickstart Guide ... - Instrumart

Krohne OPTIFLEX 1300 C Level Meter Quickstart Guide ... - Instrumart

Krohne OPTIFLEX 1300 C Level Meter Quickstart Guide ... - Instrumart

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>OPTIFLEX</strong> <strong>1300</strong> CINSTALLATION 2Temperature ranges for gasketsGasket materialProcess connection temperatureStandard versionHigh-Pressure version High-Temperature andHigh-Temperature /High-Pressureversions[°C] [°F] [°C] [°F] [°C] [°F]FKM/FPM -40…+200 -40…+390 -40…+150 -40…+300 -40…+300 -40…+570Kalrez ® 6375 -20…+200 -4…+390 -20…+150 -4…+300 -20…+300 -4…+570EPDM -50…+150 -58…+300 -50…+150 -58…+300 -50…+250 -58…+480INFORMATION!Ø4 mm / 0.15¨ single cable probe with FEP coating option only: The process connectiontemperature range is -20...+150°C / -4...+300°FINFORMATION!Single rod probes with protective sheath option only: The process connection temperature rangedepends on the protective sheath material selected.PP: -40...+90°C/-40…+194°F; PVDF: -50...+150°C /-58…+302°F; PVC: -15...+80°C / +5…+176°FProcess pressure limitsDevice versionMaximum process pressure[barg][psig]Ø8 mm / 0.3¨ single cable 40 1 580 1High-Pressure (HP) version 300 1 4350 1All other probe types and device versions 100 1 1450 11 Refer also to "Pressure / temperature table for probe selection" in the handbook09/2010 - 4000049805 - QS <strong>OPTIFLEX</strong> <strong>1300</strong> R08 enwww.krohne.com11