Proven technology: TransEnd delivers worry-free performancein a reliable, innovative design. The tested single-pulse surgecurrent capacity (per mode) meets NEMA recommendations.Sand-packed MOV arrays equally share current to suppresstransients before they reach sensitive loads while capacitorsfilter out high-frequency noise and low-level transients.TransEnd is designed and tested to withstand surge currentsin accordance with ANSI/IEEE recommendations.Instantaneous protection: TransEnd responds immediatelyand reliably to repeated high-current lightning incidentsand other transient voltage surges. All TransEnd models aredesigned to exceed the minimum performance criteriaof Bellcore and withstand larger impulses referenced in IEEE.Standard FeaturesSuperior internal construction: TransEnd’s innovative designensures dependable operation. The suppression filter componentsare bolted directly to copper bus bars, lowering systemimpedance and clamping voltage and increasing reliability.Status indicators: LEDs for all phases illuminate to clearlyindicate protection is active.Prewired: For ease of installation, TransEnd is equipped with24-inch, stranded #10 AWG pigtail conductors. The conductorscan be cut to fit the application to permit the shortestconnection for optimum performance.Single-Pulse Surge CurrentCapacity.Per PerMode* PhaseTransEnd 100: 100kA 200kATransEnd 80: 80kA 160kATransEnd 50: 50kA 100kATransEnd 25: 25kA 50kARugged, compact enclosure: Measuring only7"W x 7"H x 5"D, TransEnd easily installs intight spaces. The NEMA 4X fiberglass-reinforcedpolyester (FRP) housing features a nonremovablecover for protection against tampering.*Tested


SpecificationsSPECIFICATIONSDimensions 7"H x 7"W x 5"DWeight (all models)Enclosure Type12.7 lbs.TYPICAL CLAMPING VOLTAGE DATA6KV / 500A Combination WaveformNEMA 4X, surface-mountOperating Environment -40˚C to +60˚C, 5% to 95%noncondensing humidityConnection Method:Protection Modes:ParallelL-N, L-G, N-G, L-LSystem Model Protection ModesVoltage No. L-N L-G N-G L-L120 / 208 XN100-120/208-3GY 391 391 388 735XN80-120/208-3GY 391 391 388 735XN50-120/208-3GY 391 391 388 735XN25-120/208-3GY 408 397 392 784277 / 480 XN100-277/480-3GY 890 868 820 1665XN80-277/480-3GY 890 868 820 1665XN50-277/480-3GY 890 868 820 1665XN25-277/480-3GY 890 868 820 1665Easy to Specify.Easy to Install.EMI / RFI NOISE REJECTIONFiltering Attenuation FrequenciesAll models (L-N) w/ 6" Hook-Up WireNoise SourceFrequency 50 ft. 100 ft.100kHz -50 dB -50 dB1MHz -34 dB -39 dB10MHz -34 dB -40 dB100MHz -47 dB -53 dBAPPLICABLE APPROVALS & STANDARDSUL 1449,2nd EditionCULUL 1283NEMA LS-1OPTIONSANSI/IEEE C62.41ANSI/IEEE C62.45ANSI/IEEE C62.1ANSI/IEEE C62.11Dry ContactsSingle form “C” dry contacts for remotealarm monitoring are available as an option.To order a model with dry contacts, addsuffix “-FCC” to the standard part number.Example: XN100-120/208-3GY-FCCFITTINGSOption A: Metallic conduit installation kithas a 3/4" x 3" metallic nipple and allassociated hardware required to complete theTransEnd installation. Part No. 300-0255-001Option B: Flexible plastic conduitinstallation kit, including 18" flexibleconduit and all associated hardware requiredto complete the TransEnd installation.Part No. 300-0255-002


001001001100100NetworkCommunicationsPhones10111011001101Satellite101NetworkNetworkNetworkOscillatoryTransients• Dimmers• UPS systems• VF drivesHigh-FrequencyNoise• Fluorescentlighting• HID lighting• MotorsDamaging transientsand disruptive highfrequencynoise canbe easily observedwith a hand-heldoscilloscope.BEFORE TransEndAFTER TransEndMore than 80 percent of all transientsare internally generated by equipmentinstalled within a facility.* Theseinsidious transients continuouslyassault and deteriorate sensitiveelectronic components on circuitboards. High-frequency “noisemakers” such as power tools andfluorescent lighting can upsetthe normal operation of microprocessor-baseddevices. Withoutproper protection against noise,surges and transients, facilitiessuffer the high cost of downtime;damaged production material;lost or corrupted data; equipmentand facility losses; and evenpersonal injury.* Electric Light and <strong>Power</strong>Cahners Business InformationThe Difference is MeasurableNetwork


”24x7“ Installation hotlineTransEnd users have access to adedicated, toll-free “24x7” hotline.You can access our professionalfield service engineers by dialing:800-238-5000 8 a.m. – 5 p.m.Monday through Friday (CST)888-200-6400 Nights, weekendsand holidaysOn-line tech supportTransEnd installation manuals andrelated on-line publications are availableat http://www.jesc.com/transend/Locations in Goleta, CA and Irving, TXApplications EngineeringTel: 800-238-5000972-252-4400Fax: 972-252-7705Email: transend@jesc.comLearn more about TransEnd athttp://www.jesc.com/transendJoslyn products are manufactured in the U.S.A.© 1999, Current Technology, Inc. All Rights Reserved. Printed in U.S.A.Joslyn is a registered trademark of Current Technology, Inc. TransEnd,LoadGuard, and the Joslyn logotype are trademarks of Current Technology, Inc.FIG-CP/20M/799 J-1021