12.07.2015 Views

Variable Displacement Pump A10VSO - Group VH A/S

Variable Displacement Pump A10VSO - Group VH A/S

Variable Displacement Pump A10VSO - Group VH A/S

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

RE 92 711/03.00DRG Pressure Controller, Remote ControlFunction and equipment as for DR.A pressure relief valve can be connected to port X for remote controlapplications; this is not included in the items supplied with the DRGcontrol.The standard pressure differential setting at the control valve is20 bar. A pilot oil flow of approx. 1,5 L/min is then used. If another setting (range 10-22 bar) is required please indicate in cleartext.We recommend the following as separate pressure relief valves:DBDH 6 (hydraulic) to RE 25402 orDBETR -SO 381 with orifice ø0,8 in P (electric) to RE 29166.The max. pipe length should not exceed 2m.Sizes 28…100Bgehört nichtzum not included Lieferumfang in supplyXStatic Operating Curve(at n 1= 1500 rpm; t oil= 50° C)hysteresis and pressure rise ∆pq v maxS L1 Ldisplacement q vadjustment rangeSize 140gehört nichtzumnotLieferumfangincluded in supplyq v min20 280operating pressure p [bar]XController dataHysteresis ∆p _____________________________ max. 3 barMax. pressure riseSize 28 45 71 100 140∆p bar 4 6 8 10 12Pilot oil requirement _____________________ approx. 4,5 L/minBFlow loss at qv maxsee pages 8 and 9.S L1 LPortsBPressure portSSuction portL, L1 Case drain ports ( L1 plugged)XPilot pressure portBrueninghaus Hydromatik 18/40 <strong>A10VSO</strong>

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!