RE 92 711/03.00DG 2-position adjustment, direct controlThe pump can be set to a minimum swivel anle by connecting anexternal switching pressure to port X.This pressure acts directly onto the control piston, a min. controlpressure of at least 30 bar is required.The pump can only be switched between V gmaxand V gmin.The switching pressure p Stdepends on pump output pressure at a ratio of 1:4p St= ____ p4switching pressure p Stin X = 0 bar= ^ V gmaxswitching pressure p Stin X ≥ 30 bar or ____ p ^ = Vgmin4Before finishing your design, please request a certified drawing.BXController datamin. switching pressuremax. switching pressure30 bar280 barS L1 LUnit dimensionsSizes 28...100A 1Bport foranti-clockwise rotationport forclockwise rotationXSA 1BXA4A4A 2A 3Size 140port foranti-clockwise rotationport forclockwise rotationUnit dimensionsSize A 1A 2A 3A 4X (plugged)28 158 100 103,5 3 R 1/4"45 173 110 113,5 3 R 1/4"71 201 123,5 127,5 3 R 1/4"100 268 128,5 132,5 3 R 1/4"140 268 153 158 4,6 M14x1,5SPortsBPressure portSSuction portL, L1 Case drain ports (L1 plugged)XPilot pressure port (plugged)A 2A 3<strong>A10VSO</strong> 15/40 Brueninghaus Hydromatik