MOBILE FILTERLF 50Portable filter with a large rangeof applications.For flexible solutions duringtemporary work.The Fumex LF 50 portable filter includes the model FF 50fan <strong>co</strong>mplete with speed <strong>co</strong>ntrol.The filter is available in 2 versions, Particle/Gas and Gasfilter.For ease of selection and installation LF is available as 6<strong>co</strong>mplete kits, type LFK.The FF 50 fan can also be used without a filter as a separateunit with a bracket for use in <strong>co</strong>mbination with the Fumexrange of small extractors.Can also be used as a separate unit in <strong>co</strong>mbination with theLF VK bracket and the Fumex range of small extractors.Pure advantage


LFK 150FLFK 250FFS 600-50ESDFS 600-50ESDB-50ESDAir flow21 l/sB-50ESDBFC-50ESDS50/R54SL-050LF, L = 3 mAir flow2 X 21 l/sBFC-50ESDS50/R54SL-050LFL = 3 mRM 100-50LFT-50LF 50PGLF 50PGThe LFK 150F is a single station system using the new flexarm, providing a lower <strong>co</strong>st solution with superb flexibility.The arm and flex nozzle is antistatic (ESD) and is ideal forelectronic assembly.The LFK 250F is a twin station system using the new flexarm, providing a lower <strong>co</strong>st solution with superb flexibilityfor two workstations. The system is supplied with the hoseadaptors and inter<strong>co</strong>nnecting ductwork.LFK 350CDSK 350; w=400, h= 350, d= 300 mmSL-100LF,L = 3 mRe<strong>co</strong>mmendedair velocity0,5m/sLF 50PG /LF 50GThe LFK 350C is a unique system using a polycarbonatecabinet, for maximum peace of mind. When working withinthe cabinet you are assured that effective capture is alwaysthere. Ideal for open glue pots, analytical equipment or testareas.


Portable filter unitPart.no: LF 50PG-230 particle/gas filterPart.no: LF 50G-230 gas filterA fan and filter <strong>co</strong>mbination with a quiet running,high power <strong>co</strong>mpact fan, with integrated speed<strong>co</strong>ntroller. The LF 50PG is equipped with a multistagefilter <strong>co</strong>mprising HEPA and gas filter. The LF 50Gfilter is equipped with a gas filterSpeed <strong>co</strong>ntrol fanPart.no: FF 50-230The integrated speed <strong>co</strong>ntrol allows you to infinitelyvary the airflow to ensure maximum user <strong>co</strong>ntrol.The fan has been aerodynamically designed foroptimum performance with minimal pressure drop.This creates a low noise unit with excellent aircapacity.Particle/Gas filterPart.no: FHC 50A two stage filter that separates dust and fume particleswith the initial HEPA section. This is followed by aActivated Carbon filter for adsorption of VOCs, gasesand odours.GasfilterPart.no: FC 50A high capacity (6.5 kg) filter for applications needinggas filtration only. The high quality granulatedactivated carbon is suitable for the adsorption ofVOCs, gases and odours. Please see application guidefor more information.VTA adaptorPart.no: LF VTAA specially designed sleeve to enable the filtered airto be vented to atmosphere, e.g. <strong>co</strong>nnection to aexisting duct system.BracketPart.no: LF VKCompatible with the FF 50 fan, for wall or ceiling.mounting.


Application guide lineType of application Hazard substances Rec. LFK Rec. filterSoldering (Electronic) Resin, Lead, Terpene, Limonene, LFK 150F/250F Particle/GasBorneol, IsosyanatesSolder PotResin, Lead, Terpene LFK 175 Particle/GasGluing / BondingVOC 1 , Methylmetacrylate (MMA),Toluene, Ethyl-2-cyanoacrylate,Tetrahydrofuran,Cyklohexanone LFK 150/175 GasScreen printing Methyl ethyl ketone (MEK), Toluene LFK 150 GasCleaning / degreasing Acetone, Toluene, MEK, VOCs 1 LFK 350C GasDental Lab Dust, MMA LFK 175 Particle/GasNail salon2-Hydroxyethyl methacrylate(HEMA), MMA, Acetone, buffing dust LFK 150 Particle/GasLaser cutting Dust, metal particulate, odour LFK 150 Particle/GasMoulding Epoxi, Styrene LFK 175 GasConservation VOCs 1 LFK 175/LFK 350C Particle/GasPrecision TIG welding Welding fume, Gases, Ozone LFK 175 Particle/GasStained Glass working Lead fume, VOCs 1 LFK 175 Particle/GasBotany research VOCs 1 LFK 175 GasSculpturing VOCs 1 , silica dust, sealants LFK 150/LFK 175 Particle/Gas1Volatile Organic <strong>co</strong>mpoundsHealth aspectsParticles from fume and dust.Some particles from substances such as quartz can enter andremain in the lungs. Other particles can enter the bloodstream and are transported to other organs and areas of thebody. If the fume for instance includes lead the particles canenter the alveolus in the lungs and then transferred to theblood stream and can be transported to the skeleton.Vapour from solvents (VOC).Nearly all solvents are Volatile Organic Compounds or liquids.They are used in a many every day applications, such as<strong>co</strong>mponent cleaning, degreasing, and to dissolve productsthat are not able to be dissolved in water. They also form thedrying agent in products such as adhesives, paints, andvarnishes. Vapours from these solvents typically have anar<strong>co</strong>tic effect that <strong>co</strong>urses tiredness, dizziness andintoxication. Vapour and gases from solvents can also enteryour body by the respiratory system and then spread to thebrain and liver. The vapours from solvents are also irritatingyour eyes and respiratory system.Save your lungs!By using a suitable and effective extraction solution <strong>co</strong>mbinedwith an efficient filter system, you can reduce or even eliminatethe risk of working with airborne hazards.Particles smaller than 5 µm enter your lungs through thealveolus and can harm you in a many ways. It is best practiceto prevent the airborne hazard entering the breathing zone bycapturing it at source.


0709330210Ø100Ø125315555Ø12520265120160405295LF 50Ø11LF VK120160Technical descriptionTechnical Data LF 50Airflow0-80 l/s (max)Weight8 kgNoise level (1 m) 60 dB(a)Power195 W, 230 V 50HzParticle / GasfilterFHC 50HEPA filter H13*/Activated carbon filterGasfilterFC 50Carbon filter 6.5 kg activated carbon*Filter efficiency for a H13 filter is 99.99% for 0.3 µm particlesStatic pressure drop PaAir flow m³/h50 100 150 200 250 300 3508007507006506005505004504003503002502001501005000 10 20 30 40 50 60 70 80 90 100Air flow l/sVerkstadsvägen 2, 931 61 SKELLEFTEÅ, SwedenTel.Int. +46 910-361 80, Fax.Int. +46 910-130 22www.fumex.se info@fumex.se