12.07.2015 Views

AADvance Safety Manual - Tuv-fs.com

AADvance Safety Manual - Tuv-fs.com

AADvance Safety Manual - Tuv-fs.com

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Chapter 6 Glossary of TermsIEC 61508An international standard for functionalsafety, en<strong>com</strong>passing electrical, electronicand programmable electronic systems;hardware and software aspects.IEC 61511An international standard for functionalsafety and safety instrumented systems (SIS)for the process industry, en<strong>com</strong>passingelectrical, electronic and programmableelectronic systems, hardware and softwareaspects.indicationThe information given by an indicator.indicatorA device which can change its state to giveinformation.input (Workbench variable)In the context of an <strong>AADvance</strong> Workbenchvariable, this term describes a quantitypassed to the Workbench from a controller.instruction listAn IEC 61131 language, similar to the simpletextual language of PLCs. See 'limitedvariability language'.integerA 16-bit signed value from -32768 to 32767.One of the IEC 61131 types. See also 'word'.Kkey connectorThe receptacle on the <strong>AADvance</strong> controllerfor the program enable key. A 9-way 'D'type socket, located on the 9100 processorbase unit.Lladder diagramAn IEC 61131 language <strong>com</strong>posed of contactsymbols representing logical equations andsimple actions. The main function is tocontrol outputs based on input conditions.See 'limited variability language'.LANLocal area network. A <strong>com</strong>puter networkcovering a small physical area, characterisedby a limited geographic range and lack of aneed for leased tele<strong>com</strong>munication lines.limited variability languageA set of symbols and rules, designed to be<strong>com</strong>prehensible to process sector users andgiving the capability to <strong>com</strong>bine pre-defined,application-specific library functions toimplement a safety requirementsspecification. Typical examples are given inIEC 61131 (part 3) and include instructionlist, ladder diagram, function block diagramand sequential function chart.live insertionThe removal and then reinsertion of anelectronic module into a system while thesystem remains powered. The assumption isthat removal of the module and reinsertionwill cause no electrical harm to the system.Also referred to as 'hot swap'.low demand modeWhere the frequency of demands foroperation made on a safety-related system isno greater than one per year and no greaterthan twice the proof-test frequency.Mmanual call pointA <strong>com</strong>ponent of a fire detection and firealarm system which is used for the manualinitiation of an alarm.ModbusAn industry standard <strong>com</strong>municationsprotocol developed by Modicon. Used to<strong>com</strong>municate with external devices such asdistributed control systems or operatorinterfaces.Modbus objectA representation of the configurationsettings for a Modbus master or for itsassociated slave links, within the <strong>AADvance</strong>Workbench. The settings include<strong>com</strong>munication settings and messages.Document number 553630 Issue 7: February 2010 7-5

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!