<strong>AADvance</strong> <strong>Safety</strong> <strong>Manual</strong>NFPA 86 Requirements monitoring of safety condition of the heated systems (e.g. water level limiter insteam boilers) The EN50156 certification is only applicable where the system is applied inaccordance with this safety manual and EN 50156 requirements.NFPA 86 provides <strong>com</strong>prehensive requirements for the safe design, installation,operation, inspection, testing and maintenance of Class A,B,C and D ovens, dryers andfurnaces. The <strong>AADvance</strong> system will be certified for use with NFPA 86 <strong>com</strong>pliantsystems.The systems should be integrated in accordance with NFPA 86. In particular thefollowing shall be applied. The supplier of the application software for the <strong>AADvance</strong> controller shall provideboth the end user and the safety authority having jurisdiction with thedocumentation needed to verify that all related safety devices and safety logic arefunctional before the controller is placed in operation. In the event of a power failure, the <strong>AADvance</strong> controller (hardware and software)shall not prevent the system from reverting to a safe default condition. A safecondition shall be maintained upon the restoration of power. The control system shall have a separate manual emergency switch, independent ofthe <strong>AADvance</strong> controller, which initiates a safe shutdown. Any changes to hardware or software shall be documented, approved, andmaintained in a file on the site. System operation shall be tested and verified for <strong>com</strong>pliance with the NFPA 86standard and the original design criteria whenever the <strong>AADvance</strong> controller isreplaced, repaired, or updated. Whenever application software that contains safety logic or detection logic ismodified, system operation shall be verified for <strong>com</strong>pliance with the NFPA 86standard and the original design criteria. The NFPA 86 certification is only applicable where the system is applied inaccordance with this safety manual and NFPA 86 requirements.5-8 Document number 553630 Issue 7: February 2010

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!