12.07.2015 Views

AADvance Safety Manual - Tuv-fs.com

AADvance Safety Manual - Tuv-fs.com

AADvance Safety Manual - Tuv-fs.com

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

The <strong>AADvance</strong> SystemChapter 2.An <strong>AADvance</strong> system consists of a controller, an external operator’s station andexternal connections; a system can be built to suit your specific requirements. Thischapter describes the main <strong>com</strong>ponents that can be used to build an <strong>AADvance</strong>system.In This ChapterThe <strong>AADvance</strong> Controller............................................................................... 2-4Main Components .............................................................................................. 2-4Software Development Environment............................................................. 2-4The <strong>AADvance</strong> ControllerThe <strong>AADvance</strong> system is a new 9000 series controller specifically designed forfunctional safety and critical control applications, it provides a flexible and smaller scalesolution to the proven Trusted 8000 and 6200 products. The system can be used alsofor applications that are non-safety but still critical to a business process. This systemoffers you the ability to create a cost-effective controller to suit any one of a widevariety of applications: Critical process control Fire and gas protection systems Rotating machinery control systems Burner management Boiler and furnace control Distributed monitoring and controlThe <strong>AADvance</strong> controller is a logic solver, using processor modules, I/O modules andtermination assemblies that can easily be assembled and configured. A system is formedby one or more controllers, I/O modules, their power sources, <strong>com</strong>municationsnetworks and workstations.An <strong>AADvance</strong> controller is particularly well suited to emergency shut down and fireand gas protection applications by providing a system solution with integrated anddistributed fault tolerance. It is designed and validated to international standards andwill be certified by TÜV for functional safety control installations.The significant benefits of the <strong>AADvance</strong> controller are its performance and flexibility.Being designed to IEC 61508 it meets both SIL2 and SIL3 application requirementsfrom the basic range of modules and mixed SIL rated applications can be covered bythis range of modules.Document number 553630 Issue 7: February 2010 2-1

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!