12.07.2015 Views

1 - Wescor Inc.

1 - Wescor Inc.

1 - Wescor Inc.

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

A P P E N D I XASPECIFICATIONSReadout. . . . . . . . . . . . . . . . . . . . . . . . . . 128 x 64 dot graphic. Supports up to 8 lines of 18 charactersor numerals, with multi-lingual support.Sound. . . . . . . . . . . . . . . . . . . . . . . . . . . . Alert and Alarm signals.Keyboard . . . . . . . . . . . . . . . . . . . . . . . . . . ON, OFF, SELECT and ENTER keys.Electrode Connection. . . . . . . . . . . . . . . . 6 pin locking medical connector to mate with induction/conductivitycell, cable.Serial Connection. . . . . . . . . . . . . . . . . . . 9 pin connector compatible with RS232.Electrical. . . . . . . . . . . . . . . . . . . . . . . . . . One 9.0 Volt Lithium battery (Alkaline battery may be used)100 milliwatt power use during operation. Typical solidstate,over-current circuit protection. 3.0 Volt lithium coincell for real time clock.Sweat Induction Control. . . . . . . . . . . . . . Current profile controlled for use with Pilogel®Iontophoretic disks with multiple fail-safe circuits to limitcurrent. Nominal current is 0.5 (±.02) mA for 2.5 minutes(± 02 Sec.) Maximum fail-safe current limited to 5 mA.Sweat AnalysisReal Time Clock. . . . . . . . . . . . . . . . . . . . . Conductivity with readout in mmol/L (equivalent NaCl).Range 3 to 200 mmol/L (equivalent NaCl). Error 1% or lessfrom 25 to 150 mmol/L (equivalent NaCl). Initial sweatingrate reading 0 to 50 g/m 2 /min. Single point automatic calibration80 mmol/L (equivalent NaCl).. . . . . . . . . . . . . . . . . . . . ± 2 minutes per year.Operating Temperature . . . . . . . . . . . . . . . 15 to 30 degrees C.Storage and Transport Temperature . . . . . 0 to 60 degrees C.Regulatory . . . . . . . . . . . . . . . . . . . . . . . . . Meets EN 61326 Standards for EMC compatibility. MeetsIEC 60601 standards for safety. Manufactured under<strong>Wescor</strong>’s quality system (ISO 13485: 2003). Bears the CEmark as a Class IIa medical device. Certificate issued byBSI 0086.Physical . . . . . . . . . . . . . . . . . . . . . . . . . . . Housed in portable carrying case. Storage compartment forsupplies. Handle for ease of carrying.Height . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 cm.Width . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23 cm.Depth . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33 cm.Weight . . . . . . . . . . . . . . . . . . . . . . . . . . . . Less than 2.25 kg.43

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!