12.07.2015 Views

MegaLine ® D1-20 S/U 11Y superflex S P I C E - Kerpen

MegaLine ® D1-20 S/U 11Y superflex S P I C E - Kerpen

MegaLine ® D1-20 S/U 11Y superflex S P I C E - Kerpen

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>MegaLine</strong> ® <strong>D1</strong>-<strong>20</strong> S/U <strong>11Y</strong><strong>superflex</strong>S 1P 0I 1C 3E 4Type:KS-6Y3GC<strong>11Y</strong> 4x2xAWG 24/19Category: 5Construction:1 Conductor:2 Insulation:Twisting element:Twisting:Bound:3 Inner sheath:Bound:4 Overall screen:5 Outer sheath:bare copper wire, AWG24/19FEP, core-Ø: max. 1.2 mmpair4 pairsfleece foilEPDMfleece foiltinned copper braid, optical cover ca.90%PURcolour code:colour inner sheath:Colour outer sheath:gr/or, bl/rt, gn/ge, bl/brgrey, RAL-7035yellow, RAL-1021INDUSTRYprinting outer sheath:LEONI <strong>MegaLine</strong> <strong>D1</strong>-<strong>20</strong> S/U <strong>superflex</strong> 4P <strong>11Y</strong> SPICE Code 10134 $Production lot code$ §Meter marking§fire behaviour:flame resistance:fire load (MJ/m):acc. to IEC 60332-2-<strong>20</strong>.9 (approx.)S1 IEC 60332-2-22 IEC-60332-1-23 IEC-60332-3-244 EFP Grade 1 5 EFP grade 2Security (fire behaviour)capability characteristics:better than category 5 acc. to EN 50288 and IEC 61156 exzellentscreen propertiesbandwidth 100 MHzP1 > class E >250 MHz2 > class EA >500 MHz3 > class F >600 MHz4 > class FA >1000 MHz5 > class G >1<strong>20</strong>0 MHzPerformance (class, bandwidth)applications:Connecting cable and patch cord for generic cabling systems acc. toISO/IEC 11801 and EN 50173 (2nd edition) and also acc. to ISO/IEC24702 and EN 50173-3. Ideal for all applications of class D up to 1GbE acc. to IEEE 802.3 ab, VoIP, PoE/PoE+. For application in roughenvironment because of EPDM-insidesheath and extrem sturdy PURoutersheath. qualified for drag chain use (typical 5 Mio. cycles).Torsion suitable acc. to EN 50289-3-10.Iapplication (Ethernet, TV)1 > 100 MbE 2 > 1 GbE 3 up to 10 GbE 4 > 10 GbE 5 > 10 GbE TVmechanical characteristics:bending radius:in operation: 5 x outer diameter (min.)tensile loading (N):crush resistance (N/100mm):impact strength (quantity of impacts):90 (max.)<strong>20</strong>00<strong>20</strong>C1 AWG 27 2 AWG 26/25 3 AWG 24 4 AWG 23 5 AWG 22Construction (conductor size, tensile strengh)electromagnetic behaviour:transfer impedance at 10 MHz (mOhm/m):screen attenuation up to 1000 MHz (dB):coupling attenuation up to 1000 MHz (dB):25 (nominal value)55 (nominal value)75 (nominal value)EEMC (coupling attentuation)1 > 40 dB 2 > 50 dB 3 > 60 dB 4 > 70 dB 5 > 80 dBLEONI <strong>Kerpen</strong> GmbH Zweifaller Str. 275-287 D-52224 Stolberg, Tel. +49(0)2402-17-1, Fax +49(0)2402-75154, E-Mail info@leoni-kerpen.com, www.leoni-datacom.comprinting error, falsity and technical alterations excepted.The origin document is german. In case of error has the german translation priority.


<strong>MegaLine</strong> ® <strong>D1</strong>-<strong>20</strong> S/U <strong>11Y</strong><strong>superflex</strong>S 1P 0I 1C 3E 4Type:KS-6Y3GC<strong>11Y</strong> 4x2xAWG 24/19Electrical characteristics at <strong>20</strong>°C:DC resistance (Ohm/km):insulation resistance (GOhm x km):mutual capacitance (pF/m):signal tempo (c):signal transit time (ns/100m):Skew at 100 MHz (ns/100m):Characteristic impedance at 100 MHz(Ohm):test voltage Ueff (V):operating voltage (V):95 (max.)5 (min.)50 (approx.)0.67 (approx.)510 (approx.)<strong>20</strong> (approx.)100±51000125 (max.)INDUSTRYfrequenzMHzattenuationdB/10mtyp.Cat.5max.*typ.NEXTdBCat.5min.*typ.PS-NEXTdBCat.5min.*ACRdB@10mtyp.PS-ACRdB@10mEL-FEXTdB@10mPS-ELFEXTdB@10m100 3,15 3,4 45 35 42 32 42 32 39 32 38 24 35 21 26 <strong>20</strong>,1* following EN 50288-2-2(<strong>20</strong>04)/IEC 61156-6(<strong>20</strong>02)-Cat.5min.*1 ,18 ,32 80 65 77 62 80 65 77 62 80 64 77 61 27 -4 ,5 ,6 67 56 64 53 67 56 64 53 69 52 66 49 26 2310 ,86 ,95 63 50 60 47 62 49 59 47 61 44 65 58 30 2516 1,1 1,21 61 47 58 44 60 46 57 44 56 40 53 37 30 25<strong>20</strong> 1,25 1,36 59 46 56 43 58 44 55 43 53 38 50 35 30 2531,25 1,59 1,75 57 43 54 40 55 41 52 40 48 34 45 31 30 23,662,5 2,41 2,6 52 38 49 35 50 36 47 35 43 28 40 25 28 21,5typ.Cat.5min.*typ.Cat.5min.*typ.Cat.5min.*typ.RLdBCat.5min.*Chemical characteristics:Free of harzadous substances acc. to RoHS<strong>20</strong>11/65/EUOil resistance acc. to EN 60811-2-1ozone resistance acc. to EN 60811microbe resistant acc. to DIN VDE 0282chemical resistantHydrolysis resistant acc. to DIN 53504Free of lackbewet substances (e.g. silicon oil)Thermal characteristics:Temperature range for fixed installationTemperature range for mobile operation-40°C up to +85°C0°C up to +50°Ccertificate and approbation:Link Performance:test certificate:conform to LVD (<strong>20</strong>06/95/EC):LEONI <strong>MegaLine</strong>® systems and further commercial plug-inn connectoracc. to DIN 55350-18-4.2.1 bzw. EN 10<strong>20</strong>4$CE Logo$Article Number: Size: Outer diameter (mm): weight (kg/km): copper index (kg/km): colour of outersheath:LKD7KS5005<strong>20</strong>000 4P 8.3 (approx.) 84 (approx.) 43.7 yellow, RAL-1021packaging:drum 1000m

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!