© 2004 American Standard Inc. All rights reserved. RSP-PRC024-EN


ContentsMotor Protection ControlsDefrost ControlsDelay on Make TimersDelay on Break TimersBypass Timer and Fan Blower ControlFan Blower ControlsHead Pressure ControlsLead-Lag ControlsMulti-Mode TimerMotor StartersThermostatProgrammable ThermostatsNon-Programmable ThermostatsNew ConstructionDiagramsAccessories481314161822262728323335373839RSP-PRC024-EN3


Defrost ControlsDefrost Controls - OEM and Replacement PartsCNT03721ICM307CFeatures and Applications• 3-minute anti-short cycle protection• Low cost, time/temperature defrost• Time and temperature terminate• 10-minute fixed defrost time• HOLD input tracks compressor runtimes• Pin-selectable intervals: 30/60/90minutes• Test pins reduce test time by 256x• Integral short cycle protection: 3minutesSpecifications• 18-30 VAC• 50/60 Hz• Relay output• Form: SPSTN.O.: 1 amp• Defrost time: 10 min fixed• Interval times: pin-selectable 30/60/90minutesReplaces• Lennox: 86G16• Ranco: DT-2• Fast: 1093410CNT02897ICM315CFeatures and Applications• Solid state replacement <strong>for</strong> Ranco E-15• Reliable thermistor-type sensor is lesssusceptible to breakage, easier tomount• Replaces faulty bulb-type sensors• 10-minute fixed defrost time• Pin-selectable interval times (30/45/90)• Test pins reduce test time by 256x• Stable pin post construction• Time and temperature terminateSpecifications• 24, 120, 240 VAC• Form: SPSTN.O.: 20 ampsN.C.: 10 amps• Defrost time: 10-minute fixed• Interval times: pin-selectable 30/45/90minutesReplaces• Ranco: E-15• Avion: DFT100CNT03264ICM316CFeatures and Applications• Direct replacement <strong>for</strong> Trane21C142827G01• Low cost time/temperature defrost• Time and temperature terminate• Pin-selectable intervals: 50/70/90minutes• Test pins reduce test time by 256x• High power output (1/2 horsepower fan@ 240 VAC)• Strip heat, reversing valve outputs (24VAC, 1 amp)Specifications• 18-30 VAC• Relay output: 1/2 hp fan @ 240 VAC• Strip heat, reversing valve outputs: 24VAC, 1 amp• Defrost time: 10-minute fixed• Interval times: pin-selectable 50/70/90minutes10RSP-PRC024-EN


Defrost ControlsCNT02901ICM318CFeatures and Applications• Direct replacement <strong>for</strong> GoodmanB1226008• Low cost, time/temperature defrost• Time and temperature terminate• Pin-selectable intervals: 30/60/80minutes• Test pins reduce test time by 256x• HOLD input tracks compressor runtimes• High power output (1/2 horsepower fan@ 240 VAC)• Strip heat, reversing valve outputs (24VAC, 1 amp)Specifications• 18-30 VAC• Outdoor fan relay output: 1/2 hp fan @240 VAC• Strip heat, reversing valve outputs:24 VAC, 1 amp• Defrost time: 10-minute fixed• Interval times: pin-selectable 30/60/80minutesReplaces• Goodman: B1226008• ICM: W1001-4CNT02902ICM319CFeatures and Applications• Direct replacement <strong>for</strong> Nordyne:624519A• Low cost, time/temperature defrost• Time and temperature terminate• 10-minute fixed defrost time• Pin-selectable intervals: 30/60/90minutes• Test pins reduce test time by 256x• Recycle function melts frost on coils• Integral short cycle protection: 5minutesSpecifications• 18-30 VAC• Outdoor fan relay output: 1/2 hp fan @240 VAC• Strip heat, reversing valve outputs: 24VAC, 1 amp• Defrost time: 10-minute fixed• Interval times: pin-selectable 30/60/90minutesReplaces• Nordyne 624519A• ICM: DFORB24A2I300RSP-PRC024-EN11


Defrost ControlsDefrost Controls - OEM and Replacement PartsCNT02898ICM320CFeatures and Applications• Direct replacement <strong>for</strong> CarrierHK32FA006• Low cost, time/temperature defrost• Time and temperature terminate• 10-minute fixed defrost time• Pin-selectable intervals: 30/50/90minutes• Test pins reduce test time by 256x• Stable pin post constructionSpecifications• 18-30 VAC• Outdoor fan relay output: 10 amps @240 VAC• Form: SPSTN.O.: 2 amps• Defrost time: 10-minute fixed• Interval times: pin-selectable 30/50/90minutesReplaces• Carrier HK32FA006CNT02903ICM321CFeatures and Applications• Low cost, time/temperature defrost• Time and temperature terminate• 10-minute fixed defrost time• Pin-selectable intervals: 30/50/90minutes• Test pins reduce test time by 256x• High power output, outdoor fan (1/2horsepower fan @ 240 VAC)• Strip heat, reversing valve outputs (24VAC, 1 amp)• Integral short cycle protection: 5minutesSpecifications• 18-30 VAC• Outdoor fan relay output:N.O.: 20 ampsN.C.: 10 amps• Form: SPDT• Defrost time: 10-minute fixed• Interval times: pin-selectable 30/50/90minutesReplaces• Carrier CES01130063-00,CES01130063-01CNT02904ICM322CFeatures and Applications• Low cost, time/temperature defrost• Time and temperature terminate• 10-minute fixed defrost time• Pin-selectable intervals: 30/50/90minutes• Test pins reduce test time by 256x• High power output, outdoor fan (1/2horsepower fan @ 240 VAC)• Strip heat, reversing valve outputs (24VAC, 1 amp)Specifications• 18-30 VAC• Relay output• Form: SPDTN.O.: 20 ampsN.C.: 10 amps• Defrost time: 10-minute fixed• Interval times: pin-selectable 30/50/90minutesReplaces• Carrier CES0130024-0012RSP-PRC024-EN


Delay on Make TimersDelay On Make Timers - Ideal <strong>for</strong> Compressor StagingApplicationsIdeal <strong>for</strong> compressor staging and staggerstarting multiple motors and otherequipment. Helps to reduce powersurges.Mode of OperationWhen power is applied to the input, thetime delay begins. After the time delay iscomplete, the load energizes.Timing DiagramTMR00157ICM102BFeatures and Applications• Universal voltage operation• Higher 1.5 amp power rating• Knob-adjustable time delays• Works with anticipator-typethermostats• One model replaces many in field• Ideal <strong>for</strong> compressor staging• Simple 2-wire hookup• Compact 2” x 2” packageSpecifications• 18-240 VAC• 1.5 amps• 15 amp inrush• 40 mA holding current• Adjustable delay: .03-10-minutes(1.8-600 seconds)• Voltage drop: 2.5 V @ 1.5 ampsReplaces• Diversified: AC-800, ASC-600/601• Gemline: 1C310/1C213• Mars: 32391/32367• Robertshaw: 3310-068• Supco: TD-68, TD-69• Watsco: EAC-701-adj., -X, EAC-700-ATMR00158ICM103BFeatures and Applications• Highly precise digital timing• Switch-settable time delays• Ideal <strong>for</strong> ice machine applications• Universal voltage operation• Repeat accuracy .5% over voltage andtemperature range• Compact 2” x 2” packageSpecifications• 18-240 VAC• 1 amp• 10 amp inrush• 40 mA holding current• Switch-settable delays range from1-1,023 seconds• Voltage drop: 2.5 V @ 1 ampReplaces• Gemline:1C213• Mars: 32394/32396• Robertshaw: 3310-068• Supco: TMF-19, TMF-80• Watsco: 7061TMR00166ICM104BFeatures and Applications• Highly precise digital circuitry• High power, SPDT relay output• Input to output isolation• Works with anticipator-typethermostats• .5% repeat accuracy over voltage andtemperature range• Rugged, compact package• 115 and 240 VAC models available• 2” x 3” packageSpecifications• 18-30 VAC• Output:N.O.: 20 amps @ 240 VACN.C.: 10 amps @ 240 VACSPDT, 1 <strong>for</strong>m cKnob-adjustable time delay:10-1,000 seconds40 mA holding currentReplaces• Mars: 32394/32398RSP-PRC024-EN13


Delay on Break TimersDelay On Break Timers - Anti-Short Cycle ProtectionApplications“Anti-short cycle”“ON delay on break”Helps to protect air conditioning,refrigeration and heat pump equipmentfrom damage which may be caused bythe rapid short cycling of compressors.Mode of OperationUpon application of power, the load isenergized. When the thermostat, orother switch opens or there is a loss ofpower, the load is de-energized and thedelay period begins. The compressorwill not start again during the delayperiod. Restart occurs after the delayperiod.Timing DiagramTMR00167ICM200BTMR00160ICM201BTMR00178ICM200FBTMR00161ICM201FBTMR00162ICM203BTMR00168ICM203FBFeatures and Applications• Higher 1.5 amp power rating• Compressor lockout/anti-short cycletimer• Helps to protect compressors fromdamage caused by rapid short cycling• Simple, 2-wire hookup• Compact 2” x 2” package• ICM200, 200F: 3-minute delay• ICM201, 201F: 5-minute delay• ”F” suffix denotes 6” wire leadsSpecifications• 18-30 VAC• 1.5 amps• 15 amp inrush• 3 or 5-minute fixed time delays• Voltage drop: 3.5 V typical 4.5 Vmaximum @ 1.5 amps• 40 mA holding current minimumReplaces• Diversified: ASC-500, 501, ASC-502,ASC-505-5• Gemline:IC321, IC322• Watsco: EAC-500, EAC-501-180-W,EAC-501-300-WFeatures and Applications• Universal voltage operation• Higher 1.5 amp power rating• Compressor lockout/anti-short cycletimer• Helps to protect compressors fromdamage caused by rapid short cycling• Simple, 2-wire hookup• Compact 2” x 2” package• ”F” suffix denotes 6” wire leadsSpecifications• 18-240 VAC• 1.5 amps• 15 amp inrush• Knob-adjustable delays .03-10 minutes(1.8-600 seconds)• Voltage drop: 3.5 V typical 4.5 Vmaximum @ 1.5 amps• 40 mA holding current minimumReplaces• Diversified: ASC-500, 501, ASC-502,503, ASC-505-5• Gemline: 1C320• Mars: 32392• Robertshaw: 3310-072• Supco: TD-73• Watsco: EAC-501-ADJ., EAC-501-ADJ-X14RSP-PRC024-EN


Bypass Timer andFan Blower ControlBypass Timer - To Bypass a Switch or Device During StartupApplications”ON delay interval timer””Normally closed delay on make”Designed to bypass a control or deviceduring startup. Typically used to bypassa low pressure switch duringcompressor heat pump startup or tobypass an oil pressure switch uponstartup. Helps to eliminate nuisancelockouts.Mode of OperationWith power applied to the input, the loadenergizes immediately and remainsenergized <strong>for</strong> the length of the timedelay, regardless of the state of theswitch being bypassed.At the end of the time delay, thecondition of the load is determined bythe state of the switch.Timing DiagramTMR00159ICM175BFeatures and Applications• Designed to bypass a low pressureswitch or other device during startup• Ideal <strong>for</strong> low ambient startups• Key component <strong>for</strong> ”winter start” kits• Helps to reduce nuisance lockouts• Universal AC voltage operation• Knob-adjustable time delays• Epoxy-encapsulated circuitry• Compact 2” x 2” packageSpecifications• 18-240 VAC• 50/60 Hz• 1 amp maximum• 40 mA minimum• 10 amp inrush• Knob-adjustable time delay: 10-1,000secondsReplaces• Mars: 32395• Supco: TDP6816RSP-PRC024-EN


Bypass Timer andFan Blower ControlFan Blower Control - OFF Delay Timing Purges Residual <strong>Air</strong>Applications”OFF delay on break”Controls the circulating fan in heatpump, air conditioning and <strong>for</strong>ced airsystems. OFF delay timing functioncontinues to run the fan at the end of theheating/cooling cycle, thereby purgingducts of residual air and increasingsystem efficiency.Mode of OperationPower must be applied be<strong>for</strong>e andduring the time delay period. When theinitiate contact closes, the load energizesand remains energized as long as theinitiate contact is closed. The time delaybegins when the initiate contact opens.At the end of the time delay period, theload is turned off. If the initiate contactrecloses during the time delay period theload remains energized and the timedelay is reset to zero. Removal of inputpower during the delay turns off the loadand resets the time delay to zero. A 1-second interrogation delay is provided toavoid nuisance trips due to thermostatbounce or tampering.Timing DiagramTMR00172ICM253BFeatures and Applications• UL 873 recognition <strong>for</strong> compressorapplications• Post-purge fan delay timer• OFF delay purges ducts of residual airat the end of the heating/cooling cycle• Interrogation delay eliminates nuisancetrips due to thermostat bounce/tamperingSpecifications• 18-30 VAC• 1 amp maximum• 40 mA minimum• 10 amp inrush• Adjustable time delay: 12-390 secondsReplaces• Mars: 32393• Gemline: IC216RSP-PRC024-EN17


Fan Blower ControlsFan Blower Controls - Dual ON/OFF Delays Control FanApplications”ON delay on break” and”OFF delay on break”Controls the circulating fan in heatpump, air conditioning and <strong>for</strong>ced airsystems. ON delay on make lets airreach proper level prior to turning on thefan. OFF delay timing function continuesto run the fan at the end of the heating/cooling cycle, thereby purging ducts ofresidual air and increasing systemefficiency.Mode of OperationPower must be applied be<strong>for</strong>e andduring the time delay period. When theinitiate contact closes, the delay on makeperiod begins. The load then energizesand remains energized as long as theinitiate contact is closed. The delay onbreak period begins when the initiatecontact opens. At the end of the timedelay, the load is turned off. If the initiatecontact recloses during the time delay,the load remains energized and the timedelay is reset to zero. Removal of inputpower during the delay turns off the loadand resets the time delay to zero.Timing DiagramTMR00171ICM251BFeatures and Applications• Drives fan directly• High power, relay output• Dual function fan delay timer• Controls the circulating fan in heatpump, A/C and <strong>for</strong>ced air systems• OFF delay controls fan relay to purgeducts of residual air at the end of theheating/cooling cycle• ON delay allows air to reach the propercom<strong>for</strong>t level prior to energizing the fan• 115 and 230 VAC are also available,please consult factorySpecifications• 18-30 VAC• Output: N.O.: 20 amps @ 240 VACN.C.: 10 amps @ 240 VAC• Time delays adjustable:ON: 1-180 secondsOFF: 12-390 secondsReplaces• Mars: 32377, 32378, 3237918RSP-PRC024-EN


Fan Blower ControlsTMR00164ICM254BFeatures and Applications• Dual function fan delay timer• Controls the circulating fan in heatpump, A/C and <strong>for</strong>ced air systems• OFF delay controls fan relay to purgeducts of residual air at the end of theheating/cooling cycle• ON delay allows air to reach the propercom<strong>for</strong>t level prior to energizing the fanSpecifications• 18-30 VAC• 1 amp maximum• 40 mA minimum• 10 amp inrush• Time delays adjustable:ON: 1-180 secondsOFF: 12-390 secondsReplaces• Honeywell: S876A1016• Watsco: PSTD-000-060W,PSTD-000-005WTMR00165ICM255CFeatures and Applications• Low cost open board design• High power, relay output• Dual function fan delay timer• Controls the circulating fan in heatpump, A/C and <strong>for</strong>ced air systems• OFF delay purges ducts of residual air• ON delay allows air to reach the propercom<strong>for</strong>t level prior to energizing the fanSpecifications•18-30 VAC• N.O.: 20 amps @ 240 VACN.C.: 20 amps @ 240 VAC• Time delays fixed: ON: 1 secondOFF: 60 secondsReplaces• Bard: 8201-056• Mars: 32393• Snyder-General: 1395336• Watsco: 5893• Rheem: 42-22515-01, 42-22515-02,42-22515-03RSP-PRC024-EN19


Fan Blower ControlsFan Blower Controls - Direct OEM Replacement PartsCNT03261ICM270CFeatures and Applications• Dual function fan delay timer• Controls the circulating fan in heatpump, A/C and <strong>for</strong>ced air systems• OFF delay purges ducts of residual air• ON delay allows air to reach the propercom<strong>for</strong>t level prior to energizing the fanSpecifications• 18-30 VAC• Contact ratings: Heat/Cool SpeedN.O.: 20 amps @ 240 VACN.C.: 10 amps @ 240 VAC• Time delays blower off time adjustable:90, 120, 150, 180 secondsReplaces• Robertshaw: 695-003• Evcon: 2702-300• Rheem: 47-22827-01, 47-22827-81,47-22827-82, 47-22828-01, 47-22828-02• Honeywell: ST9120A1006,ST9120A12004CNT03262ICM271CFeatures and Applications• Reliable solid state fan blower control• <strong>Specifically</strong> <strong>designed</strong> to replace populargas furnace centers• Pin selectable blower delays• High power, relay output• Dual function fan delay timer• Controls the circulating fan in heatpump, A/C and <strong>for</strong>ced air systems• OFF delay purges ducts of residual air• ON delay allows air to reach the propercom<strong>for</strong>t level prior to energizing the fanSpecifications• 18-30 VAC• Contact ratings:N.O.: 20 ampsN.C.: 10 amps• Fixed time delaysReplaces• Robertshaw: 695-10020RSP-PRC024-EN


Fan Blower ControlsCNT03277ICM272CFeatures and Applications• Cooling control module with fan delay• Integral low voltage terminal boardwith field thermostat wiring• Electronic air cleaner output• High power, relay output• DC output <strong>for</strong> fan relays and 1st stageof electric heater control• Interlock circuitry prevents 2nd and 3rdstage electric heat energization withoutproper fan operationSpecifications• 18-30 VAC• Contact ratings:N.O.: 20 ampsN.C.: 10 amps• Time delay: factory fixed at 60 secondsReplaces• Texas Instruments: 2FD-1CNT03263ICM275CFeatures and Applications• Microprocessor-based fan blowercontrol• Built in humidity relay• Manually adjustable post-purge offdelay from 60-240 seconds• Electronic air cleaner outputSpecifications• 18-30 VAC• Contact ratings:20 amps @ 240 VAC on high10 amps @ 240 VAC on lowReplaces• Robertshaw: 695-101RSP-PRC024-EN21


Head Pressure ControlsHead Pressure Controls - Low Ambient Fan ControlCNT02905ICM325HCFeatures and Applications• Integral heat pump bypass circuitryallows electronic bypass of speedcontrol• Eliminates overshoots common to on/off and pressure switch controls• Helps prevent evaporator freeze-ups,low pressure cut-outs and liquidsluggedcompressors in low ambientconditions• One model covers 120-480 VAC• Features: hard start, low temperaturebypass, isolated 24 VAC supply• Controls up to 3 refrigerant circuits• Typical application: A/C & heat pumps• 4.5” x 3” x 1.75”Specifications• Input–Control:18-30 VAC, 50/60 Hz1.8 VA maximum–Line Input: 120-480 VAC• Output–Maximum: 10 amps–Minimum: 100 mAReplaces• Hoffman: 800/800A/800AA/814-50,816-10• Ranco: E31Series• Johnson Controls: P66• ACT: FM2000CNT03679ICM325K2Canada OnlyFeatures and Applications• One model covers 120 to 600 VAC• Features: hard start, low temperaturebypass, isolated 24 VAC supply• Eliminates overshoots common to on/off and pressure switch controls• Controls one refrigerant circuit• Typical application: refrigeration andA/C• ICM325K2: with ICM376 probe, 70-100• 4.5” x 3” x 1.75”Specifications• Input–Control:18-30 VAC–Line Input: 120-600 VAC– Frequency: 50/60 Hz• Output–Maximum: 10 amps–Minimum: 100 mACNT02906ICM326HCCNT02907ICM327HCFeatures and Applications• Built in trans<strong>for</strong>mer eliminates cost,reduces installation time and simplifieswiring• Helps prevent evaporator freeze-ups,low pressure cut-outs and liquidsluggedcompressors in low ambientconditions• Features: hard start, low temperaturecutoff, high temperature bypass• Ideal <strong>for</strong> line voltage air conditioningand refrigeration• 4.5” x 3” x 2”Specifications• ICM326H: 120 or 208/240 VAC• ICM327H: 480 VAC• Frequency: 50/60 Hz• Output–Maximum: 10 amps–Minimum: 100 mAReplaces• Hoffman: 800/800A/800AA/814-50,816-10• Ranco: E31Series• Johnson Controls: P6622RSP-PRC024-EN


Head Pressure ControlsTypical System Diagram <strong>for</strong> ICM326H Head Pressure ControlRSP-PRC024-EN23


Head Pressure Controls3-Phase Head Pressure Controls - With LCD DiagnosticsCNT03525ICM336CNT03524ICM337Features and Applications• Temperature, pressure, milliamp or DCvoltage input• True sine wave output• Modulates voltage and frequency• LCD display <strong>for</strong> easy setup andmonitoring• No need to change existing fan motor• 8.25” x 12.5” x 14”SpecificationsICM336: 208-240 VAC1-3 HPICM337: 460 VAC1-5 HPReplaces• Motor Master III• Hoffmann24RSP-PRC024-EN


Head Pressure ControlsHead Pressure Control AccessoriesCBT00804ACC-OE-01Outdoor EnclosureFeatures and Applications• Rugged steel construction• Easy to mount• Helps to protect controls from harshenvironmental conditions such astemperature, shock, humidity andvibration• Ideal <strong>for</strong> use with ICM head pressurecontrols• 4.25” x 6.25” x 6.25”TDR00312ICM380Features and Applications• Optional pressure transducer <strong>for</strong>ICM336/ICM337 3-phase head pressurecontrolsSEN00864ICM379Features and Applications• Probe <strong>for</strong> use with ICM325H, ICM326Hand ICM327H head pressure controlswith optional heat pump bypassfeatureRSP-PRC024-EN25


Lead-Lag ControlsLead-Lag Controls - Reliable Long Life SwitchingCNT03266ICM600Features and Applications• True dual stage control• Built in thermostat– adjustable set point– adjustable deadband– adjustable sequencer• Regulates 1 or 2 heating/coolingsystems• Compact housing• Safety system halon contacts• Memory on power loss• Accelerated test mode• Isolated inputs• Isolated solid state outputs• Built in anti-short cycle delays• Status LEDs• Advance state switch• Ideal <strong>for</strong> refrigeration applications,communication substations, watertreatment plants anywhere redundantsystems are used• 4.25” x 8.5” x 2”Specifications• 18-30 VAC• 2 amps maximum• Frequency: 50/60 Hz• Power consumption: 2 wattsmaximum/lockout• Adjustable thermostat features:–Set point: 55-90°–Deadband: 2-20°–Sequencer: 1-28 days26RSP-PRC024-EN


Multi-Mode TimerMulti-Mode Digital Timer - Versatile, Simple, AccurateTMR00187ACS-8Features and Applications• Relay socket• 8-pin octal plug-in base• Locating key ensures proper orientation• For use with ICM408, ICM410-427,ICM500-505Specifications•10 amps up to 480 VACReplaces• Diversified: RB-08RSP-PRC024-EN27


Motor StartersRapidStart ® Motor Starters - Current SensingBy monitoring the compressor currentupon start-up, RapidStart ® is able toengage the hard start capacitor <strong>for</strong>precisely the correct amount of time,ensuring maximum starting torquewithout the risk of supplying too muchcurrent into the start winding. A timedsafety circuit is provided in the event themotor fails to start within 2 seconds.Current sensing hard start preciselyincreases starting torque.KIT07685ICM803Features and Applications• Operates from 95-288 VAC• Patented current sensing circuitry• Easy to install, 2 wires• OEM approved• Solid-state circuitry• Boosts starting torque• Disengages upon start• Recycles instantly (less than 1 second)• Fuse protection• Not effected by voltage or currentfluctuations• Not effected by ambient temperaturesSpecifications• Voltage: 95-288 VAC• Max Input Voltage: 502 VAC• Oper. Temp. Range: -40°C to +65°C• 88-106 Mfd. 330 V capacitor• For 1/2 to 3 HP applicationsReplaces• Supco: SPP-8• Kickstart: TO5, TO-5KIT07686ICM805Features and Applications• Operates from 95-288 VAC• Patented current sensing circuitry• Easy to install, 2 wires• OEM approved• Solid-state circuitry• Boosts starting torque• Disengages upon start• Recycles instantly (less than 1 second)• Fuse protection• Not effected by voltage or currentfluctuations• Not effected by ambient temperaturesSpecifications• Voltage: 95-288 VAC• Max Input Voltage: 502 VAC• Oper. Temp. Range: -40°C to +65°C• 145-175 Mfd. 330 V capacitor• For 2 to 5 HP applicationsReplaces• Kickstart: KS1KIT07687ICM810Features and Applications• Operates from 95-288 VAC• Patented current sensing circuitry• Easy to install, 2 wires• OEM approved• Solid-state circuitry• Boosts starting torque• Disengages upon start• Recycles instantly (less than 1 second)• Fuse protection• Not effected by voltage or currentfluctuations• Not effected by ambient temperaturesSpecifications• Voltage: 95-288 VAC• Max Input Voltage: 502 VAC• Oper. Temp. Range: -40°C to +65°C• 243-292 Mfd. 330 V capacitor• For 3 1 /2 to 10 HP applications28RSP-PRC024-EN


Motor StartersRapidStart ® Series 803/805/810 - The Current AdvantageWiring DiagramWiring And System DiagramsSystem DiagramAlternate Wiring ConfigurationsPSC UnitsCapacitor StartInduction Run Double Capacitor OFF Cycle HeatDimensions803/805/810(Universal view) 803 805/810RSP-PRC024-EN29


Motor StartersRapidStart ® Motor Starters - Voltage SensingICM’s differential voltage sensingproducts employ patented circuitrywhich monitors differential compressorauxiliary voltage, determines the state ofthe motor and precisely engages anddisengages the start capacitor.A timed safety circuit is provided in theevent the motor fails to start within 2seconds.KIT07688ICM850Features and Applications• Increases starting torque up to 500%• Ensures precise starts• Reduces inventory• Not affected by ambient temperature• Recycles instantly (less than onesecond)• Dual voltage operation: either 115 or240 VAC motors• Fuse protection• Not effected by voltage or currentfluctuationsSpecifications• Voltage: 90-277 VAC• Max Input Voltage: 390 VAC• Oper. Temp. Range: -40°C to +65°C43-52 Mfd. 330 V capacitor• For up to 1 1 /2 HP applicationsReplaces• Supco: SPP-5• Mars: 32701• A-1: WXS-5KIT07689ICM860Features and Applications• Increases starting torque up to 500%• Ensures precise starts• Reduces inventory• Not affected by ambient temperature• Recycles instantly (less than onesecond)• Dual voltage operation: either 115 or240 VAC motors• Fuse protection• Not effected by voltage or currentfluctuationsSpecifications• Voltage: 90-277 VAC• Max Input Voltage: 390 VAC• Oper. Temp. Range: -40°C to +65°C88-106 Mfd. 330 V capacitor• For 2 to 5 HP applicationsReplaces• Supco: SPP-6• Mars: 32702• A-1: WXS-630RSP-PRC024-EN


Motor StartersRapidStart ® Series 850/860 - The Differential PotentialApplicationsWater coolersVending MachinesHousehold refrigerators (115 or 230 VAC)Commercial refrigeration(115 or 230 VAC)<strong>Air</strong> conditioners and heat pumpsDimension, System, and Wiring DiagramsDimensions System Diagram Wiring DiagramRapidStart® ComparisonHard StartSoft StartDifferential Potential PTCR TimingCurrent Relay Relay Devices DevicesGemline HS600 and HS650MARS 32701 and 32702Conventional ROBERTSHAW 600-052 and 600-057ICM 3-Wire Relay SUPCO SPP5, SPP6, and SPP7 SUPCO SPP8RAPIDSTART ® KICKSTART Capacitor Kit WATSCO WSX-5 and WSX-6 WATSCO WSX-1Self Adjusting Yes No No No NoUses Current Differential Technology Yes No No No NoUses Potential Motor Start Relay No Yes Yes No NoTwo Wires, Non-Polarized Yes Yes No Yes YesRecycles Instantly Yes Yes Yes No NoSenses Whether Motor Started or Not Yes Yes Yes No NoReplaces 3-Wire Relay and Capacitor Kit Yes Yes N/A No NoUL Recognized #E11867 Yes Yes No No NoApproved by Compressor Manufacturers Yes Yes Yes No NoApproved by Equipment Manufacturers Yes Yes Yes No NoUsed by OEM Manufacturers Yes No No No NoSafety Cut-off Yes No No No NoTrue Power Factor Starting Not Required Yes Yes Yes YesFactory Calibration No Yes Yes Yes YesVoltage Sensitive No No No Yes NoPTCR Device No No No No YesTiming Circuit Device No No No Yes YesAffected by Ambient Temperature No No No Yes YesRSP-PRC024-EN31


ThermostatProgrammableServiceFirst Item No. THT02403 THT02404 THT02405 THT02406 THT02407Mfg. No. SC3000 SC3001 SC3006 SC3201 SC3801FeaturesSingle Stage 2 Stage Heat Pump Heat Cool Status LEDs Backlit AutoChangeover 7-DayProgrammable ProgrammableFanNon-Programmable BatteryHardwired MillivoltCompatible4 or 5 WireCompatible FreezeProtectionKeypadLockout Non-ProgrammableServiceFirst Item No. THT02394 THT02412 THT02395 THT02413 THT02396 THT02397 THT02398 THT02399 THT02400 THT02401 THT02402Mfg. No. SC1600 SC1601 SC1800 SC1801 SC1900 SC1901 SC2000 SC2001 SC2200 SC2201 SC2300FeaturesSingle Stage 2 Stage Heat Pump Heat Cool Status LEDs Non-Programmable Battery Hardwired MillivoltCompatible 4 or 5 WireCompatible FreezeProtection 32RSP-PRC024-EN


Programmable ThermostatSeries SC3000BatteryTHT02403 (SC3000)7-Day Programmable, Single Stage Heat/ Single Stage Cool or Single StageHeat Pump, Manual ChangeoverTerminations: RC, RH, W, Y, O, B, GFeatures• Elegant Design• 7-Day Programmable• Large Backlit LCD Display*• Precise Temperature Sensing• Non-Volatile Program Memory• Easy Access Terminal Block• Zoning System Compatible• Compatible with Standard 24-volt AC<strong>Heating</strong>/Cooling Systems• Integral Four-Minute Anti-Short CycleProtection• Temporary and Vacation Hold• Mercury-free, Environmentally Safe* ICM Series SC3000 is not backlitSimpleset 7-Day Programming• Simple programming with an ICMexclusive "step back" feature• Simple and versatile programmingoptions:- 7-Day Programming - Individuallyprogram each day or program oneday and copy it <strong>for</strong> the entire weekBatterySpecifications• Electrical Rating: 24 VAC (18 to 30 VAC)1 amp maximum per terminal4 amp maximum total load• Temperature Control Range: 45°F to90°F Accuracy: (± 1 °F)RSP-PRC024-EN33


Programmable ThermostatSeries SC3001 / SC3006 / SC3201 / SC3801HardwiredRemote sensor unit <strong>for</strong>SC3801THT02404 (SC3001)7-Day Programmable, Single Stage Heat/ Single Stage Cool or Single StageHeat Pump, Manual ChangeoverTerminations: RC, RH, C, W, Y, O, B, GTHT02406 (SC3201)7-Day Programmable, 2 Stage HeatPump, Manual ChangeoverTerminations: R, C, Y1, Y2, W2, O, B, G,E, LSEN01226 (ACC-RT104)Optional <strong>for</strong> use with SC3801 <strong>for</strong> remotetemperature sensor mountingTerminations: S1, S2THT02405 (SC3006)7-Day Programmable, Single Stage Heat/ Single Stage Cool or Single StageHeat Pump, Auto ChangeoverTerminations: RC, RH, C, W, Y, O, B, GTHT02407 (SC3801)7-Day Programmable, 2 Stage Heat / 2Stage Cool or 2 Stage Heat Pump,Auto ChangeoverTerminations: R, C, W 1 /O/B, Y1 , W2, Y2,G, S 1 , S234RSP-PRC024-EN


Non-Programmable ThermostatSeries SC1600 / SC1800 / SC1900 / SC2000 / SC2200 / SC2300BatteryFeatures• Elegant Design• Zoning System Compatible• Adjustable Differential• Large LCD Temperature Display• Precise Temperature Sensing• Easy Access Terminal Block• Selectable Fahrenheit or Celsius• Compatible with Standard 24-volt AC<strong>Heating</strong>/Cooling Systems• Integral Five-Minute Anti-Short CycleProtection• Mercury-free, Environmentally Safe• Manual ChangeoverSpecifications• Electrical Rating: 24 VAC (18 to 30 VAC)1 amp maximum per terminal4 amp maximum total load• Temperature Control Range: 45°F to90°F Accuracy:


Non-Programmable ThermostatSeries SC1601 / SC1801 / SC1901 / SC2001 / SC2201 / SC2211HardwiredTHT02412 (SC1601)Heat Only, Single Stage HeatNo FanTerminations: R, C, WTHT02397 (SC1901)Cool Only, Single Stage CoolTerminations: R, C, Y, GTHT02401 (SC2201)2 Stage Heat PumpTerminations: R, C, Y1, Y2, W2, O, B, G,E, LTHT02413 (SC1801)Heat Only, Single Stage HeatTerminations: R, C, W, GTHT02399 (SC2001)Single Stage Heat / Single Stage Cool orSingle Stage Heat PumpTerminations: R, C, W, Y, O, B, G36RSP-PRC024-EN


New ConstructionSeries SC055 to SC075Series SC605 to SC075SApplicationsThe SC055 to SC075S series thermostatsare low cost, single set point thermostatsintended <strong>for</strong> use as temporary devices toprovide heating or cooling to allowdrywall to dry during construction. Alsocan be used <strong>for</strong> low ambient cutoffswitch.Specifications• Electrical Rating: 24 VAC (18 to 30 VAC)amp maximum• Temperature Control Range: 55°F to75°F Accuracy: (± 5°F)HardwiredDryout ThermostatsTHT02385 (SC055) toTHT02392 (SC075)• Two-wire installation• Five fixed set point models to choosefrom: 55°F to 75°F in five-degreeincrementsTHT02387 (SC060S) toTHT02393 (SC075S)• Three-wire installation• Switched fan, 3 modes- Fan only- Off- Heat or Cool• Four fixed set point models to choosefrom: 60°F to 75°F in five-degreeincrementsServiceFirst Item No. THT02385 THT02386 THT02387 THT02388 THT02389 THT02390 THT02391 THT02392 THT02393Mfg. No. SC055 SC060 SC060S SC065 SC065S SC070 SC070S SC075 SC075STemperature Range 55°F ±5° 60°F ±5° 60°F ±5° 65°F ±5° 70°F ±5° 70°F ±5° 70°F ±5° 75°F ±5° 75°F ±5°2-Wire 3-Wire Heat Cool Switched Fan RSP-PRC024-EN37


DiagramsBattery CompartmentLarge LCD Display(Backlit <strong>for</strong> Hardwired Models)Batteries IncludedElectric/Gas SwitchIntegrated Anti-ShortCycle ProtectionFreeze Protection SwitchOptional InsulatedWall PlateFan SwitchEasy Access Terminal BlockMode Switch38RSP-PRC024-EN


AccessoriesWallplatesPLT03837 (ACC-WP01)PLT03838 (ACC-WP02)Need more wall coverage? Choose anICM insulated wall plate.The fast, easy solution <strong>for</strong> hiding wallproblems.• Rugged, flexible construction• Foam gasket prevents drafts throughwall opening• Hidden mounting screws (included) <strong>for</strong>a sleek appearanceChoose from two convenient sizes:• ACC-WPO1 - 4 27 /32" x 5 15 /16"• ACC-WP02 - 5 19 /32" x 7 1 /2"Remote Sensor <strong>for</strong> SC3801SEN01226 (ACC-RT104)Need to monitor the temperature awayfrom the thermostat? Choose an ICMremote sensor.The fast, easy solution <strong>for</strong> temperaturesensing problems.• For tamper-prone areas• Poor air flow areas• Troubled applications• Foam gasket prevents drafts throughwall openingMounts to standard 2" x 4" outlet box• ACC-RT 104 - 2 3 /4" x 4 1 /2"RSP-PRC024-EN39


Literature Order NumberFiling HierarchyDateSupersedesStocking LocationRSP-PRC024-ENService Products / ControlsFebruary 2004RSP-D-107 0399InlandTrane has a policy of continuous product and product data improvement and reserves the right to changedesign and specifications without notice.