Base Station Antenna Systems 2008 Product Selection Guide - AVW

Base Station Antenna Systems 2008 Product Selection Guide - AVW Base Station Antenna Systems 2008 Product Selection Guide - AVW

12.07.2015 Views

Teletilt ® Remote Electrical Downtilt SystemJunction BoxesElectricalInternal lightning protectionGas discharge tube to ground protection: REA PE-80 compliant per testmethod IEEE C62.31 protection rating (all lines to ground):IEEE C62.41.2 § 6.1.2 current pulse profile, 8/20 μs,200 repetitions minimum at 600 AIEC 61312-1 annex B current pulse profile, 10/350 μs,10 repetitions minimum at 600 AEU certificationCE, CB; low voltage directive 73/23/EECEMC/Surge immunityETSI EN 300 386–V1.3.2 2003 with EN 55022 1998 schedule forclass A device; GR 1089 core issue 3; FCC CFR 47 part 15 subpart Bfor class A; EN 61326-1, EN 55011Safety standard EN 60950, UL 60950Connectors/InterfacesInput portOutput ports4-way model7-way modelGrounding lugMountingMounting typePipe diameterMount materialOne AISG 8-pin male, IP67, data and powerFour AISG 8-pin female, IP67, data and powerSeven AISG 8-pin female, IP67, data and powerM8Vertical pipe mount or wall/flat surface mount, included2 to 4.5 in (51 to 114 mm)Stainless steelMechanical/EnvironmentalNet weight4-way model2.2 lb (1.0 kg)7-way model2.35 lb (1.07 kg)Shipping weight4-way model4 lb (1.82 kg)7-way model4.15 lb (1.89 kg)DimensionsProduct—L x W x D7.3 x 6.2 x 2 in (185 x 158 x 51 mm)Shipping—L x W x D11 x 10.25 x 5.5 in (279 x 260 x 140 mm)Housing materialAluminumHousing colorGrayMaximum wind speed125 mph (201 km/h)Temperature range–40° C to +65° CHumidity Up to 100%IP ratingIP65Specifications IEC-68, ETSI 300-019Environmental ETSI EN 300 019-2-2, 2-3, & 2-4; NEBS GR 63 core issue 2 2002zone 4 earthquake; NEBS GR 63 core issue 2 2002 § 5.1, 5.2, 5.3, 5.4,5.5, 5.6, & 5.7All specifications are subject to change. Please see www.andrew.com for the most current information.Andrew Wireless Solutions www.andrew.com71

Teletilt ® Remote Electrical Downtilt SystemLightning Protection UnitTeletilt ® ATLP200-001 Lightning Protection UnitThe ATLP200-001 lightning protection unit provides added protection to all Teletilt systemcomponents. This unit is designed to withstand a short circuit current level of 10/350 μs, 16kA (lineto ground; per IEC 61312-1 standard). It is equipped with a grounding nut and must be grounded(ground cable included). Its 8-pin male and female AISG interfaces feed data and power through thecontroller to the first junction box, actuator/RET (remote electrical downtilt) device.Mounting brackets are included to allow the ATLP200-001 lightning protection unit to be mounted toeither a pole or a flat surface. ATLP200-001Lightning protection for ATC200 series remote controlvariable electrical downtilt systemPart NumberATLP200-001IncludesDescriptionLightning protection unit1 Pipe bracket1 Band clamp2 Wall bracket2 M8 carriage bolt, stainless steel, 25mm long2 M8 hex nut, stainless steel2 M8 lock washer, stainless steel1 Ground cable (#6 AWG with lugs), 2 ft (610 mm)1 Installation bulletinNote: Mounting brackets are included to allow the ATLP200-001 lightning protection unit to be mounted to eithera pole or a flat surface.ElectricalInternal lightning protectionOvercurrent protectionCircuit insertion resistanceProtected side clamping,nominal voltageEU certificationEMC/Surge immunitySafety standard EN 60950, UL 60950Gas discharge tube to ground protection: REA PE-80 compliant per testmethod IEEE C62.31Transorb and varistor secondary protection stageProtection rating (all lines to ground):IEEE C62.41.2 § 6.1.2 current pulse profile, 8/20 μs,200 repetitions min. at 600 AIEC 61312-1 annex B current pulse profile, 10/350 μs,10 repetitions min. at 600 APTC fuseSignal lines: under 1.0 ohm Power lines: under 0.5 ohmRS-485 lines: ± 10 V+12 V: +17 V to –0.6 V+24 V: +28 V to 0.6 V–48 V: +0.6 V to –58 VCE, CB; low voltage directive 73/23/EECETSI EN 300 386–V1.3.2 2003 with EN 55022 1998 schedule for classA device; GR 1089 core issue 3; FCC CFR 47 part 15 subpart B for classA; EN 61326-1, EN 5501172Andrew Wireless Solutions www.andrew.com

Teletilt ® Remote Electrical Downtilt SystemJunction BoxesElectricalInternal lightning protectionGas discharge tube to ground protection: REA PE-80 compliant per testmethod IEEE C62.31 protection rating (all lines to ground):IEEE C62.41.2 § 6.1.2 current pulse profile, 8/20 μs,200 repetitions minimum at 600 AIEC 61312-1 annex B current pulse profile, 10/350 μs,10 repetitions minimum at 600 AEU certificationCE, CB; low voltage directive 73/23/EECEMC/Surge immunityETSI EN 300 386–V1.3.2 2003 with EN 55022 1998 schedule forclass A device; GR 1089 core issue 3; FCC CFR 47 part 15 subpart Bfor class A; EN 61326-1, EN 55011Safety standard EN 60950, UL 60950Connectors/InterfacesInput portOutput ports4-way model7-way modelGrounding lugMountingMounting typePipe diameterMount materialOne AISG 8-pin male, IP67, data and powerFour AISG 8-pin female, IP67, data and powerSeven AISG 8-pin female, IP67, data and powerM8Vertical pipe mount or wall/flat surface mount, included2 to 4.5 in (51 to 114 mm)Stainless steelMechanical/EnvironmentalNet weight4-way model2.2 lb (1.0 kg)7-way model2.35 lb (1.07 kg)Shipping weight4-way model4 lb (1.82 kg)7-way model4.15 lb (1.89 kg)Dimensions<strong>Product</strong>—L x W x D7.3 x 6.2 x 2 in (185 x 158 x 51 mm)Shipping—L x W x D11 x 10.25 x 5.5 in (279 x 260 x 140 mm)Housing materialAluminumHousing colorGrayMaximum wind speed125 mph (201 km/h)Temperature range–40° C to +65° CHumidity Up to 100%IP ratingIP65Specifications IEC-68, ETSI 300-019Environmental ETSI EN 300 019-2-2, 2-3, & 2-4; NEBS GR 63 core issue 2 2002zone 4 earthquake; NEBS GR 63 core issue 2 2002 § 5.1, 5.2, 5.3, 5.4,5.5, 5.6, & 5.7All specifications are subject to change. Please see www.andrew.com for the most current information.Andrew Wireless Solutions www.andrew.com71

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!