Base Station Antenna Systems 2008 Product Selection Guide - AVW
Base Station Antenna Systems 2008 Product Selection Guide - AVW Base Station Antenna Systems 2008 Product Selection Guide - AVW
Teletilt ® Remote Electrical Downtilt SystemControllersElectricalPower supplyInput–48 Vdc; 24 VdcPower consumption5 W idle state, 70 W maximumOutput24 V, 50 W maximumEU certificationCE, CBEMC/Surge immunity EN 55022, EN 55024Safety standard IEC 60950-1Connectors/InterfacesSerial interfaceLAN interfaceAISG interfacedc 2.1 bias tee interfaceAlarm relayMechanical/EnvironmentalNet weightShipping weightDimensionsProduct—L x W x DShipping—L x W x DHousing materialHousing colorMountingTemperature rangeHumidityIP ratingAltitudeEnvironmental*Enclosure recommended for outdoor use.RS-232 DB9, femaleEthernet RJ458–pin female, IP67, data and power65 SMB, femaleTwo, normally open3.5 lb (1.6 kg)4.5 lb (2.1 kg)19 x 8.1 x 1.7 in (483 x 206.2 x 43.6 mm)21 x 12 x 6.1 in (533 x 305 x 155 mm)Aluminum extrusionBlack19 in rack mount, 1U height–20° C to +55° C, indoor use5 to 95%, non-condensingIP63, indoor and outdoor*–100 to +3000 mETSI EN 300 019-2-2, 2-3, & 2-4; NEBS GR 63 core issue 2 2002 zone4 Earthquake; NEBS GR 63 core issue 2 2002 § 5.1, 5.2, 5.3, 5.4, 5.5,5.6, & 5.7IPV4/SNMP Command ProtocolRead and set site tilts remotelyCommission remote firmware upgradesAlarm notification, remote site maintenance, and administration web interfaceAll specifications are subject to change. Please see www.andrew.com for the most current information.Andrew Wireless Solutions www.andrew.com67
Teletilt ® Remote Electrical Downtilt SystemControllersTeletilt ® ATC200-LITE-USB Portable ControllerThe ATC200-LITE-USB controller serves as an interface between a local PC and remote electricaldowntilt (RET) devices, as well as SmartBeam antennas (with adjustable horizontal beamwidth,azimuth boresite direction, and electrical downtilt) installed at a base station site. This unit canmanage up to 32 AISG device addresses, independently, with the use of multiple junction boxes.Both a USB and an RS-232 serial cable are included with this unit. With these options, theATC200-LITE-USB controller can connect directly to a local PC through its USB or COM port(where a USB port is not available) for local access and operations.The ATC200-LITE-USB supports AISG 1.0, 1.1, and 2.0 actuators, even in a mixed RET system.The controller’s LEDs, on the front panel of the controller, signal that power and data communicationis present. The power LEDs, located nearest to the dc IN port, indicate power is supplied from thecontroller to the RET system. The data LED, located nearest to the RS-232 serial port, indicates datatransfer between the controller and the RET devices. This unit is designed for portable use.Part NumberATC200-LITE-USBIncludesDescriptionPortable controller1 Antenna system control unit1 Power supply (3.0 A at 24 Vdc)4 Power adapters (Australia/Asia, Europe, UK, NA/SA)1 USB cable1 RS-232 serial cable*2 Quick reference guides (User guide available online.)*1 Site configuration worksheet (For pads of 50 worksheets, order ATFK-Config Pad.)*Available at www.andrew.com. ATC200-LITE-USBConverts RS-232 signal from PC to the RS-485 signal that controls the tilt commands in a remote control actuatorVisit www.andrew.com to register and receive software updates68Andrew Wireless Solutions www.andrew.com
- Page 17 and 18: Dual Band806-960/1710-2180 MHz60-75
- Page 19 and 20: Notes18Andrew Wireless Solutions w
- Page 21 and 22: 1800/1900/UMTSFeatures and Benefits
- Page 23 and 24: 1800/1900/UMTSSingle Band Sector Ba
- Page 25 and 26: 1800/1900/UMTS1710-1880 MHz80-95°
- Page 27 and 28: 1800/1900/UMTS1710-2180 MHz80-95°
- Page 29 and 30: 1800/1900/UMTS1850-1990 MHz60-75°
- Page 31 and 32: 1800/1900/UMTS1850-1990 MHz80-95°
- Page 33 and 34: 1800/1900/UMTS1920-2180 MHz80-95°
- Page 35 and 36: Notes34Andrew Wireless Solutions w
- Page 37 and 38: 700/800/900 MHzFeatures and Benefit
- Page 39 and 40: 700/800/900 MHzSingle Band Sector B
- Page 41 and 42: 700/800/900 MHz806-896 MHz30 30 30
- Page 43 and 44: 700/800/900 MHz806-896 MHz80-95° H
- Page 45 and 46: 700/800/900 MHz806-960 MHz80-95° H
- Page 47 and 48: 700/800/900 MHz870-960 MHz60-75° H
- Page 49 and 50: Notes48Andrew Wireless Solutions w
- Page 51 and 52: WiMAXFeatures and BenefitsSector An
- Page 53 and 54: WiMAXSingle Band Sector Base Statio
- Page 55 and 56: Notes54Andrew Wireless Solutions w
- Page 57 and 58: 30-512 MHzFeatures and BenefitsGrou
- Page 59 and 60: 30-512 MHz30-174 MHz60-75° Horizon
- Page 61 and 62: 30-512 MHz406-512 MHz60-75° Horizo
- Page 63 and 64: Teletilt ® Remote Electrical Downt
- Page 65 and 66: Teletilt ® Remote Electrical Downt
- Page 67: Teletilt ® Remote Electrical Downt
- Page 71 and 72: Teletilt ® Remote Electrical Downt
- Page 73 and 74: Teletilt ® Remote Electrical Downt
- Page 75 and 76: Teletilt ® Remote Electrical Downt
- Page 77 and 78: Teletilt ® Remote Electrical Downt
- Page 79 and 80: Teletilt ® Remote Electrical Downt
- Page 81 and 82: Teletilt ® Remote Electrical Downt
- Page 83 and 84: Teletilt ® Remote Electrical Downt
- Page 85 and 86: Teletilt ® Remote Electrical Downt
- Page 87 and 88: Teletilt ® Remote Electrical Downt
- Page 89 and 90: Teletilt ® Remote Electrical Downt
- Page 91 and 92: Teletilt ® Remote Electrical Downt
- Page 93 and 94: Teletilt ® Remote Electrical Downt
- Page 95 and 96: Notes94Andrew Wireless Solutions w
- Page 97 and 98: Concealment SolutionsOverview Micro
- Page 99 and 100: Concealment SolutionsMicro AcCELLer
- Page 101 and 102: Concealment SolutionsAntenna Concea
- Page 103 and 104: Concealment SolutionsAntenna Concea
- Page 105 and 106: Mounting Hardware and AccessoriesFo
- Page 107 and 108: Mounting Hardware and AccessoriesFo
- Page 109 and 110: Mounting Hardware and AccessoriesFo
- Page 111 and 112: Mounting Hardware and AccessoriesFo
- Page 113 and 114: Mounting Hardware and AccessoriesFo
- Page 115 and 116: Applications/Engineering NotesOverv
- Page 117 and 118: Applications/Engineering NotesBasic
Teletilt ® Remote Electrical Downtilt SystemControllersElectricalPower supplyInput–48 Vdc; 24 VdcPower consumption5 W idle state, 70 W maximumOutput24 V, 50 W maximumEU certificationCE, CBEMC/Surge immunity EN 55022, EN 55024Safety standard IEC 60950-1Connectors/InterfacesSerial interfaceLAN interfaceAISG interfacedc 2.1 bias tee interfaceAlarm relayMechanical/EnvironmentalNet weightShipping weightDimensions<strong>Product</strong>—L x W x DShipping—L x W x DHousing materialHousing colorMountingTemperature rangeHumidityIP ratingAltitudeEnvironmental*Enclosure recommended for outdoor use.RS-232 DB9, femaleEthernet RJ458–pin female, IP67, data and power65 SMB, femaleTwo, normally open3.5 lb (1.6 kg)4.5 lb (2.1 kg)19 x 8.1 x 1.7 in (483 x 206.2 x 43.6 mm)21 x 12 x 6.1 in (533 x 305 x 155 mm)Aluminum extrusionBlack19 in rack mount, 1U height–20° C to +55° C, indoor use5 to 95%, non-condensingIP63, indoor and outdoor*–100 to +3000 mETSI EN 300 019-2-2, 2-3, & 2-4; NEBS GR 63 core issue 2 2002 zone4 Earthquake; NEBS GR 63 core issue 2 2002 § 5.1, 5.2, 5.3, 5.4, 5.5,5.6, & 5.7IPV4/SNMP Command ProtocolRead and set site tilts remotelyCommission remote firmware upgradesAlarm notification, remote site maintenance, and administration web interfaceAll specifications are subject to change. Please see www.andrew.com for the most current information.Andrew Wireless Solutions www.andrew.com67