The <strong>Base</strong> <strong>Station</strong> <strong>Antenna</strong> <strong>Systems</strong><strong>Product</strong> Qualification ProgramTo ensure published performance of our products, allfamilies of Andrew’s base station antenna systemsare tested and must successfully complete rigorousenvironmental stress screening tests per IEC 68-2standards prior to release for manufacturing. <strong>Antenna</strong> testing range Cold test at –40° C Dry heat at +70° C Temperature shock: –40° C to +70° C, 10 cycles Salt Fog: 35° C with 5% salt solution for 96 hours Rain simulation Humidity: 10 24-hour cycles at 95% relative humidity Vibration: 20 cycles of 10 to 150 Hz, with 1.5-hourdwell at resonant frequency on each axis Electrostatic discharge testing for lightning Single shock test (used for transportation) Continuous shock test (used for transportation) Solar radiation test (UV) at 50° C for up to 1000 hours100% IM and Return Loss Testing On All <strong>Antenna</strong>sCompetent Outdoor <strong>Antenna</strong> RangesHot/Cold Test ChamberNear Field Pattern ScannerAndrew Wireless Solutions www.andrew.com9