Designing and Commissioning an Ultraviolet Light Disinfection ...
Designing and Commissioning an Ultraviolet Light Disinfection ...
Designing and Commissioning an Ultraviolet Light Disinfection ...
- No tags were found...
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
Warden, WashingtonWarden UV <strong>Disinfection</strong> SystemMaximum Month Average Flow 0.474 mgdMaximum Day Flow0.60 mgdPeak Hour Flow1.2 mgdUV Design Flow0.60 mgdUV Tr<strong>an</strong>smitt<strong>an</strong>ce for Design Flow 55 %UV Lamp TypeLow PressureHigh IntensityLamp OrientationVerticalNumber of B<strong>an</strong>ks Total 6Number of Redund<strong>an</strong>t B<strong>an</strong>ks 1Lamps Per B<strong>an</strong>k 40Total Lamps 240Ch<strong>an</strong>nel Width (less baffle width) 4 ftCh<strong>an</strong>nel Depth6 ftCh<strong>an</strong>nel Length33.83 ftTotal Reactor Volume6,065 galReactor Water Depth5 ftEffective Reactor Volume5,054 galUV Model/M<strong>an</strong>ufacturerAquaRay 40 HO