Accept<strong>an</strong>ce of Checkpoint BioassayConclusions• Run A UV dose > 115 mJ/cm 2 @ 55% UVT• Typical UVT in Warden UV Reactor > 65% UVT• Three modules delivers > 115 mJ/cm 2 @ 55% UVT• Three modules on at all times will deliver a validatedUV dose at flows up to 0.6 mgdWarden agreed to operate a minimum of three UVmodules at all times to ensure validated dose isdelivered at all times