Acceptance of Checkpoint BioassayVelocity Measurements at Low Flow (Run A)• Hired WSU Water Research Center Researchers• Acoustic Doppler Velocimeter Measurements• Tests Designed per NWRI Guidelines• 0.3 m upstream of first bank• 0.3 m downstream of last bank• Cross-sections equally spaced• Not less than 3 x 3 grid per cross-section• Measurements 6 – 12 cm apart
Acceptance of Checkpoint BioassayVelocity Profile Measurement Selected Locations
- Page 1 and 2: DESIGNING & COMMISSIONING AN ULTRAV
- Page 3 and 4: Presentation Outline• Background
- Page 6 and 7: Water Reclamation Facilities Warden
- Page 8 and 9: Warden, WashingtonUV
- Page 10 and 11: Warden, WashingtonWarden UV Disinfe
- Page 12 and 13: Checkpoint BioassayWarden WRF Check
- Page 14 and 15: Checkpoint Bioassay Test Flow Schem
- Page 16 and 17: Checkpoint Bioassay Test Setup
- Page 18 and 19: Checkpoint Bioassay Test Results
- Page 22 and 23: Acceptance of Checkpoint BioassayAc
- Page 24 and 25: Acceptance of Checkpoint BioassayEx
- Page 26: Questions
Accept<strong>an</strong>ce of Checkpoint BioassayVelocity Measurements at Low Flow (Run A)• Hired WSU Water Research Center Researchers• Acoustic Doppler Velocimeter Measurements• Tests Designed per NWRI Guidelines• 0.3 m upstream of first b<strong>an</strong>k• 0.3 m downstream of last b<strong>an</strong>k• Cross-sections equally spaced• Not less th<strong>an</strong> 3 x 3 grid per cross-section• Measurements 6 – 12 cm apart