11 Calibrating11.6. Serial Measurement Board memoryContinuedDelete SMB dataThis section describes how to delete the data stored on the SMB memory or the controllermemory, when creating spare parts.StepAction1. On the ABB menu, tap Calibration and tap to select a mechanical unit.2. Tap SMB memory and then tap Advanced.The following functions are available:• Clear Cabinet Memory• Clear SMB Memory3. Tap Clear Cabinet Memory if the controller should be replaced and used as aspare part.A list of the SMB data stored in the controller is displayed. Tap Clear to delete thememory for the selected robot. Repeat the procedure for all robots in the controllermemory.4. Tap Clear SMB Memory if the SMB should be replaced and used as a spare part.A list of the SMB data stored is displayed. Tap Clear to delete the memory for theselected robot. Repeat the procedure for all robots using this SMB board.2823HAC 16590-1 Revision: B