10 Systems10.3.8. Restart from previously stored system data (B-start)10.3.8. Restart from previously stored system data (B-start)What happens with my current system?The current system is in system failure mode since the previous session was shut downwithout saving the image file correctly. All changes made to the system before the shut downhas been lost. Therefore, the system needs to be restarted from the most recent successful shutdown or load another system.Note that all changes made to the system data since the previous session has been lost.Restart from previously stored system dataThis section describes how to restart from previously stored image file.StepAction1. On the ABBmenu, tap Restart.The restart dialog is displayed.2. Tap Advanced... to select restart method.The select restart method dialog is displayed.3. Tap B-start, then tap OK.4. Tap B-start to restart the controller.The controller is restarted using the system data from the most recent successfulshut down.2623HAC 16590-1 Revision: B