8 Handling inputs and outputs, I/O8.4. Safety I/O signalsContinuedSignalnameSOFTGSI Soft General stop 1 = Soft stop enabled From panel board to maincomputerSUPES1 Superior stop, chain1 1 = Chain closed From panel board to maincomputerSUPES2 Superior stop, chain2 1 = Chain closed From panel board to maincomputerSOFTSSI Soft Superior stop 1 = Soft stop enabled From panel board to maincomputerCH1CH2ENABLE1All switches in runchain 1 closedAll switches in runchain 2 closedEnable from MC (readback)1 = Chain closed From panel board to maincomputer1 = Chain closed From panel board to maincomputer1 = Enable, 0 = breakchain 1ENABLE2_1 Enable from AXC1 1 = Enable, 0 = breakchain 2ENABLE2_2 Enable from AXC2 1 = Enable, 0 = breakchain 2ENABLE2_3 Enable from AXC3 1 = Enable, 0 = breakchain 2ENABLE2_4 Enable from AXC4 1 = Enable, 0 = breakchain 2PANFANPANEL24OVLDDRVOVLDSuperv. of fan inControl moduleFrom panel board to maincomputerFrom panel board to maincomputerFrom panel board to maincomputerFrom panel board to maincomputerFrom panel board to maincomputer1 = OK, 0 = Error From panel board to maincomputerOverload, panel 24V 1 = Error, 0 = OK From panel board to maincomputerOverload, drivemodulesDRV1LIM1 Read back of chain 1after limit switchesDRV1LIM2 Read back of chain 2after limit switchesDRV1K1 Read back of contactorK1, chain 1DRV1K2 Read back of contactorK2, chain 2DRV1EXTCONTDRV1PANCH1DRV1PANCH2DRV1SPEEDDRV1TEST1DRV1TEST2DescriptionExternal contactorsclosedDrive voltage forcontactor-coil 1Drive voltage forcontactor-coil 2Read back of op. modeselectedA dip in run chain 1 hasbeen detectedA dip in run chain 2 hasbeen detectedBit valuecondition1 = Error, 0 = OK From panel board to maincomputer1 = Chain 1 closed From axis computer to maincomputer1 = Chain 2 closed From axis computer to maincomputer1 = K1 closed From axis computer to maincomputer1 = K2 closed From axis computer to maincomputer1 = ContactorsclosedFrom axis computer to maincomputer1 = Voltage applied From axis computer to maincomputer1 = Voltage applied From axis computer to maincomputer0 = Man. mode lowspeedToggledToggledFrom - ToFrom axis computer to maincomputerFrom axis computer to maincomputerFrom axis computer to maincomputer3HAC 16590-1 Revision: BContinues on next page241

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!