T10/1236-D Revision 20 18 July 2001If the STANDBY bit is one and the IDLE bit is one, a value of zero in the standby condition timer indicates the logicalunit shall enter the standby condition when the idle condition timer equals zero.Figure 3 shows graphically the relationships between the different power conditions and their timers.YesIDLEBit = 1NoNoidleconditiontimer = 0YesEnter idle conditionYesSTANDBYBit = 1NoNostandbyconditiontimer = 0YesEnter standby condition8.3.10 Protocol specific LUN pageFigure 3 — Power conditions flowchartThe protocol specific LUN page (see table 164) provides protocol specific controls that are associated with a logicalunit. See the protocol standard (see 3.1.41) for definition of the protocol specific mode parameters.Table 164 — Protocol specific LUN pageBitByte7 6 5 4 3 2 1 00 PS Reserved PAGE CODE (18h)1 PAGE LENGTH (n-1)2 Reserved PROTOCOL IDENTIFIER3nProtocol specific mode parameters206 dpANS <strong>SCSI</strong> <strong>Primary</strong> <strong>Commands</strong> - 2 (SPC-2)