18 July 2001 T10/1236-D Revision 20used on the same logical unit then any START STOP UNIT commands power condition request shall override thepower condition pages power control.No power condition shall affect the supply of any power required for proper operation of the service deliverysubsystem.On the receipt of a command the device server shall adjust itself to the power condition that allows the command toexecute. The timer that maps to this power condition and any lower power condition timers shall be reset on receiptof the command. On completion of the command the timer associated with this power condition shall be restarted.Logical units that contain cache memory shall implicitly perform a SYNCHRONIZE CACHE command (see SBC)for the entire medium prior to entering into any power condition that prevents access the media (e.g., the spindlebeing stopped).The logical unit shall use the power condition page to control the power conditions after a power on or a hard resetuntil a START STOP UNIT command is received that sets power conditions.Table 163 — Power condition pageBitByte7 6 5 4 3 2 1 00 PS Reserved PAGE CODE (1Ah)1 PAGE LENGTH (0Ah)2 Reserved3 Reserved IDLE STANDBY4 (MSB)IDLE CONDITION TIMER7 (LSB)8 (MSB)STANDBY CONDITION TIMER11 (LSB)An IDLE bit of one indicates that the logical unit shall use the IDLE CONDITION TIMER field to determine the length ofinactivity time to wait before entering the idle condition. An IDLE bit of zero indicates that the logical unit shall notenter the idle condition.A STANDBY bit of one indicates that the logical unit shall use the STANDBY CONDITION TIMER field to determine thelength of inactivity time to wait before entering the standby condition. A STANDBY bit of zero indicates that thelogical unit shall not enter the standby condition.The IDLE CONDITION TIMER field indicates the inactivity time in 100 millisecond increments that the logical unit shallwait before entering the idle condition.If the IDLE bit is one, a value of zero in the idle condition timer indicates the logical unit shall enter the idle conditionon completion of any command.The STANDBY CONDITION TIMER field indicates the inactivity time in 100 millisecond increments that the logical unitshall wait before entering the standby condition. This timer shall only count if the idle condition timer is equal tozero.If the STANDBY bit is one and the IDLE bit is zero, a value of zero in the standby condition timer indicates the logicalunit shall enter the standby condition on completion of any command.dpANS <strong>SCSI</strong> <strong>Primary</strong> <strong>Commands</strong> - 2 (SPC-2) 205

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!