12.07.2015 Views

SCSI Primary Commands - 2.pdf

SCSI Primary Commands - 2.pdf

SCSI Primary Commands - 2.pdf

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

T10/1236-D Revision 20 18 July 2001device without degrading the device’s operation or reliability outside the limits specified by the manufacturer of thedevice. The state of the parameter control bits for parameter 0003h is specified in table 142.Table 142 — Parameter control bits for start-stop cycle counter parameters (0003h and 0004h)The accumulated start-stop cycles (parameter code 0004h) is a parameter provided by the device server. Theaccumulated start-stop cycles parameter shall not be saveable by the application client using the LOG SELECTcommand (i.e., the log parameter DS bit shall be one). The parameter value is a 4-byte binary number. The valueindicates how many start-stop cycles the device has detected since its date of manufacture. The time at which thecount is incremented during a start-stop cycle is vendor specific. For rotating magnetic storage devices, a singlestart-stop cycle is defined as an operational cycle that begins with the disk spindle at rest, continues while the diskaccelerates to its normal operational rotational rate, continues during the entire period the disk is rotating,continues as the disk decelerates toward a resting state, and ends when the disk is no longer rotating. For deviceswithout a spindle or with multiple spindles, the definition of a single start-stop cycle is vendor specific. The count isincremented by one for each complete start-stop cycle. No comparison with the value of parameter 0003h shall beperformed by the device server. The state of the control bits for parameter 0004h is specified in table 142.8.2.10 Supported log pagesBit Value DescriptionDU 0 Value provided by device serverDS 1 Device server does not support saving of parameterTSD 0 Device server manages saving of parameterETC 0 No threshold comparison is made on this valueTMC xx Ignored when ETC is 0LBIN 1 The parameter is in binary formatLP 1 The parameter is a list parameterThe supported log page (see table 143) returns the list of log pages implemented by the target. Targets thatimplement the LOG SENSE command shall implement this log page.Table 143 — Supported log pagesBitByte7 6 5 4 3 2 1 00 PAGE CODE (00h)1 Reserved2 (MSB)PAGE LENGTH (n-3)3 (LSB)4SUPPORTED PAGE LISTnThis page is not defined for the LOG SELECT command. This log page returns the list of supported log pages forthe specified logical unit.The PAGE LENGTH field specifies the length in bytes of the following supported page list.The SUPPORTED PAGE LIST field shall contain a list of all log page codes implemented by the target in ascendingorder beginning with page code 00h.186 dpANS <strong>SCSI</strong> <strong>Primary</strong> <strong>Commands</strong> - 2 (SPC-2)

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!