12.07.2015 Views

Silver-Lube® Corrosion resistant bearing units

Silver-Lube® Corrosion resistant bearing units

Silver-Lube® Corrosion resistant bearing units

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

T1T3T2PSFT SERIESTable 11PSFT <strong>Silver</strong>-Lube ® Two-Bolt Flange – Housing Load CapacityRHP MAXIMUM HOUSING LOAD (N) AT 20°CDESIGNATION T1 T2 T3 MAXIMUMINTERMITTENT CONTINUOUS CYCLICALLOADING LOADING LOADINGINTERMITTENT CONTINUOUS CYCLICALLOADING LOADING LOADINGINTERMITTENT CONTINUOUS CYCLICALLOADING LOADING LOADINGFIXING BOLTTORQUE (Nm)PSFT20CR 4400 2200 1200 1900 900 500 1300 700 400 18PSFT3/4CR 4400 2200 1200 1900 900 500 1300 700 400 18PSFT25CR 4400 2200 1200 3000 1500 800 1400 700 400 25PSFT1CR 4400 2200 1200 3000 1500 800 1400 700 400 25PSFT30CR 5900 2900 1600 3300 1600 900 2000 1000 500 30PSFT1.3/16CR 5900 2900 1600 3300 1600 900 2000 1000 500 30PSFT1.1/4RCR 5900 2900 1600 3300 1600 900 2000 1000 500 30PSFT35CR 6400 3200 1700 3900 2000 1100 2800 1400 800 35PSFT1.1/4CR 6400 3200 1700 3900 2000 1100 2800 1400 800 35PSFT1.7/16CR 6400 3200 1700 3900 2000 1100 2800 1400 800 35PSFT40CR 9000 4500 2500 3900 2000 1100 3300 1600 900 40PSFT1.1/2CR 9000 4500 2500 3900 2000 1100 3300 1600 900 40UPST SECTIONTable 12PST <strong>Silver</strong>-Lube ® Take-Up – Housing Load CapacityRHP MAXIMUM HOUSING LOAD (N) AT 20°CDESIGNATIONUIntermittent Continuous CyclicalLoading Loading LoadingPST20CR 5700 2800 1600PST3/4CR 5700 2800 1600PST25CR 5400 2700 1500PST1CR 5400 2700 1500PST30CR 8100 4000 2300PST1.3/16CR 8100 4000 2300PST1.1/4RCR 8100 4000 2300PST35CR 7800 3900 2200PST1.1/4CR 7800 3900 2200PST1.7/16CR 7800 3900 2200PST40CR 8100 4000 2300PST1.1/2CR 8100 4000 2300Note that there is no Maximum Fixing Bolt Torque applicable for Take-Up Units.MRFL (kN)17.0117.0116.2516.2524.3224.3224.3223.5223.5223.5224.2624.26STATIC ELECTRICITY GENERATIONStatic electricity may be generated by <strong>Silver</strong>-Lube ® <strong>bearing</strong> <strong>units</strong> under certain application conditions.<strong>Silver</strong>-Lube ® <strong>bearing</strong>s are therefore not recommended for use in explosive or flammable environments. If <strong>Silver</strong>-Lube ®<strong>bearing</strong> <strong>units</strong> are used in flammable or explosive applications the <strong>bearing</strong> insert must be earthed.12

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!