12.07.2015 Views

Chain actuator – Thrust force 300N – Max stroke 400 mm - Market

Chain actuator – Thrust force 300N – Max stroke 400 mm - Market

Chain actuator – Thrust force 300N – Max stroke 400 mm - Market

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

ACK4<strong>Chain</strong> <strong>actuator</strong> <strong>–</strong> <strong>Thrust</strong> <strong>force</strong> <strong>300N</strong> <strong>–</strong> <strong>Max</strong> <strong>stroke</strong> <strong>400</strong> <strong>mm</strong>


Standard brackets fortop and bottom hungwindowsVertical mounting bracketsset for top hung windowsLarge swivel brackets setfor top hung windowsTechnical CharacteristicsACK42ACK44Power supply voltage 230V ~ 50 Hz 24V DC<strong>Max</strong> reco<strong>mm</strong>ended load in thrust/traction position <strong>300N</strong> 300 NStroke end adjustable at 10-15-20-25-30-35-40 cmAbsorbed current 0,32 A 2,10 AIdle translation speed 28 <strong>mm</strong>/s 18 <strong>mm</strong>/sDuration of the idle <strong>stroke</strong> 14 s 22 sDouble electric insulation YES -Service type S2 of 2 min S2 of 3 minOperating temperature -5 +50 °CProtection degree of electric devicesIP55Stroke end regulation (in closing) to window frame10 <strong>mm</strong>Connection of two or more <strong>actuator</strong>s in parallelYESConnection/synchronisation of two or three ACK4*on the same windowWith kit USA2-3 only<strong>Chain</strong> position controlYESElectronics with acoustic device to warn the user of wrong installationYESWeight** of installed equipment1,9 Kg(*min. distance between the motors: 1500<strong>mm</strong>)(**the weight indicated in the table is subject to eventual variations according to the accessories chosen.)


Description for technical specificationsElectric <strong>actuator</strong> TOPP model ACK4 with double-link chain made of STAINLESS steel, containedin a die-cast body of aluminum alloy coated by epoxy powders, complete with support andfitting accessories for top and bottom hung windows. Operation at 230V~ 50Hz, as analternative, at 24V d.c.. <strong>Max</strong>. traction and thrust <strong>force</strong> <strong>300N</strong>. <strong>Max</strong>. <strong>stroke</strong> of 40 cm.Electronic <strong>stroke</strong>-end adjustable every 5 cm. by an external handgrip.Electronics with acoustic device that warns of any eventual incorrect installations.Electronic <strong>stroke</strong> end through an external handgrip on both sides of the <strong>actuator</strong> body. IfACK4required, USA2/3 synchronization unit available, for the simultaneous running of 2 or 3<strong>actuator</strong>s on the same window. Protection degree of electric devices IP55. CE marked devicecomplying with the following directives: EEC 89/336, EEC 73/23 and following amendments.


C20<strong>Chain</strong> <strong>actuator</strong> <strong>–</strong> <strong>Thrust</strong> <strong>force</strong> 200N <strong>–</strong> <strong>Max</strong> <strong>stroke</strong> 360 <strong>mm</strong>


C20 <strong>Chain</strong> <strong>actuator</strong> with top hung bracketsC20 <strong>Chain</strong> <strong>actuator</strong> with bottom hung bracketsC20 <strong>Chain</strong> <strong>actuator</strong> with vertical mounting bracketsTechnical characteristicsC20/230 C20/24Power supply voltage 230V - 50Hz min. 21V - max. 28V DC<strong>Max</strong> reco<strong>mm</strong>ended load in thrust/traction position 200N 200NStroke adjustable at240 and 360<strong>mm</strong>Absorbed current 0,12A 0,36AIdle translation speed 10 <strong>mm</strong>/s 9,7 <strong>mm</strong>/sDuration of the idle <strong>stroke</strong> 36 s 37 sDouble electric insulation YES -Service type S2 <strong>–</strong> 3 min S2 <strong>–</strong> 3 minOperating temperature -5 + 50°CProtection degree of electric devices IP 30Stroke end regulation (in closing) to window frameNOT NECESSARYConnection of two or more <strong>actuator</strong>s in parallelYESStroke endElectronic in openingBy amperometric absorption in closure<strong>Chain</strong>Double-link, steelWeight* of the fitted machine 0,970 kg 0,940 kg*(the weight indicated in the table is subject to eventual variations according to the accessories chosen)


8965.515.134283339574248361377.43402842142153474.83621.5344864.53.5565.536248281411.7438938967.3Description for technical specificationsElectric <strong>actuator</strong> TOPP, model C20 with double link articulated chain, contained in asuitable casing, complete with support and fitting accessories for top and bottom hungwindows. Operation at 230V~ 50Hz or, as an alternative, at 24 V d.c..<strong>Max</strong>imum applicable load 200N. Rapid coupling for the adjustment to the frame.Stroke adjustable by an external selector, at 20 and 38 cm. CE marked device complyingwith the following directives: EEC 89/336, EEC 73/23 and following amendments.C20


C30<strong>Chain</strong> <strong>actuator</strong> <strong>–</strong> <strong>Thrust</strong> <strong>force</strong> <strong>300N</strong> <strong>–</strong> <strong>Max</strong> <strong>stroke</strong> 380 <strong>mm</strong>


C30 <strong>Chain</strong> <strong>actuator</strong> with top hung bracketsC30 <strong>Chain</strong> <strong>actuator</strong> with vertical mounting bracketsC30 <strong>Chain</strong> <strong>actuator</strong> with bottom hung bracketsTechnical CharacteristicsC30/230 C30/24Power supply voltage 230V ~ 50Hz 24V d.c.<strong>Max</strong>imum applicable load in thrust: 300 N 300 N<strong>Max</strong>imum applicable load in traction: 300 N 300 NStrokes (may be selected in any moment)200 and 380 <strong>mm</strong>Absorbed current 0,32 A 1,3 AIdle translation speed 24 <strong>mm</strong>/s 19 <strong>mm</strong>/sDuration of the idle <strong>stroke</strong> 16 s 20 sDouble electric insulation YES -Service type S2 of 3 min S2 of 3 minOperating temperature -5 +50 ºCProtection degree of electric devicesIP30Adjustment of the window frame connection15<strong>mm</strong>.Pins adjustment for swivel brackets15<strong>mm</strong>.Connection in parallel of two or more <strong>actuator</strong>sYESConnection and synchronization of two or three C30* on the same windowOnly with control unit USA2/3<strong>Chain</strong> position controlYESElectronics with acoustic device to warn the user of wrong installation (buzzer)YESWeight** of installed equipment 1,1 Kg 1,1 Kg(* minimum distance among the two or three motors: 1500 <strong>mm</strong>.)(**the weight indicated in the table is subject to eventual variations according to the accessories chosen.)


Description for technical specificationsElectric <strong>actuator</strong> TOPP, model C30 with double link articulated chain, contained in a suitablecasing, complete with support and fitting accessories for top and bottom hung windows.Operation at 230V~ 50Hz or, as an alternative, at 24 V d.c..<strong>Max</strong>imum applicable load 300 N. Rapid coupling for the adjustment to the frame.Stroke adjustable by an external selector, at 20 and 38 cm.Electronics with acoustic device that warns of any eventual incorrect installations.If required, pre-set version for the USA2/3 synchronization unit available,C30for the simultaneous running of 2 or 3 <strong>actuator</strong>s on the same window.CE marked device complying with the following directives: EEC 89/336, EEC 73/23 andfollowing amendments.


C40<strong>Chain</strong> <strong>actuator</strong> <strong>–</strong> <strong>Thrust</strong> <strong>force</strong> <strong>400</strong>N <strong>–</strong> <strong>Max</strong> <strong>stroke</strong> 500 <strong>mm</strong>


C40 <strong>Chain</strong> <strong>actuator</strong> with top hung bracketsC40 <strong>Chain</strong> <strong>actuator</strong> with bottom hung bracketsC40 <strong>Chain</strong> <strong>actuator</strong> with vertical mounting bracketsTechnical CharacteristicsC40/230 C40/24Power supply voltage 230V ~ 50Hz 24V d.c.<strong>Max</strong>imum applicable load in thrust <strong>400</strong> N <strong>400</strong> N<strong>Max</strong>imum applicable load in traction <strong>400</strong> N <strong>400</strong> NStrokes (may be selected in any moment)100, 150, 200, 250, 300, <strong>400</strong>, 500 <strong>mm</strong>.Absorbed current 0,24 A 1,1 AIdle translation speed 21 <strong>mm</strong>/s 18 <strong>mm</strong>/sDuration of the idle <strong>stroke</strong> 24 s 28 sDouble electric insulation YES -Service type S2 of 3 min S2 of 3 minOperating temperature -5 +50 ºCProtection degree of electric devicesIP55Adjustment of the window frame connectionNot necessary.Connection in parallel of two or more <strong>actuator</strong>sYESConnection and synchronization of two or three C40* on the same windowOnly with control unit USA2/3<strong>Chain</strong> position controlYESEnd of <strong>stroke</strong>Electronic in openingWith current absorption in closingElectronics with acoustic device to warn the user of wrong installationYESWeight** installed equipment 1,9 Kg 1,9 Kg(* minimum distance among the two or three motors: 1500 <strong>mm</strong>.)(**the weight indicated in the table is subject to eventual variations according to the accessories chosen)


Description for technical specificationsElectric <strong>actuator</strong> TOPP, model C40 with double link articulated chain, contained in a suitablecasing, complete with support and fitting accessories for top and bottom hung windows.Operation at 230V~ 50Hz or, as an alternative, at 24 V d.c.. <strong>Max</strong>imum applicable load <strong>400</strong>N.Rapid hooking for the adjustment to the frame. <strong>Max</strong> <strong>stroke</strong> 50 cm. Electronic possibility to adjustthe end of <strong>stroke</strong> at 10, 15, 20,25, 30, 40, 50 cm. by an external handgrip. Stroke-endthrough current absorption for closing. Safety device for traction <strong>force</strong> reduction in the last10 cm. Electronics with acoustic devices that warns of any eventual incorrect installationsC40Protection degree of electric devices IP 55. If required, pre-set version for the USA2/3synchronization unit available, for the simultaneous running of 2 or 3 <strong>actuator</strong>s on the samewindow. CE marked device complying with the following directives: EEC 89/336, EEC 73/23and following amendments.


USA2_USA3Connection and synchronization unit for 2 or 3 ACK4, C30 or C40


Description for technical specificationsThe USA is a device that synchronizes, controls and monitors the simultaneous running of ACK4 <strong>actuator</strong>s fitted on the same frame. Itbecomes essential when two or three ACK4 chain <strong>actuator</strong>s are set up on large size windows, providing a regular and even movement ofthe vents, to guarantee the security of the frame and connected motors.The microprocessor of this unit checks in real time the <strong>actuator</strong>s feeding power, consumption and speed. When any one of the checkedparameters does not meet the standard, the USA automatically disconnects the feeding and signals, by a pilot light, which <strong>actuator</strong> is causingthe failure.Only two or three <strong>actuator</strong>s, preset with a five-wire cable connection, can be linked to the USA2 and USA3. The unit is fitted ina grey shock-resistant plastic case. Both the unit and the <strong>actuator</strong>s can work either at 230V <strong>–</strong> 50Hz or 24V DC. It is preset for connectionto all wind, rain, air-conditioning, smoke and heat evacuation systems.CE marked device complying with the following regulations: EEC 89/336, EEC 73/23 and following amendments.Technical characteristicsUSA2 USA3 USA2 USA3Power supply voltage 230 V ~ 50 Hz 24 V DCAutput voltage 230 V ~ 50 Hz 24 V DCTotal max. absorption applied (ACK4) 0,64 A 0,96 A 4,2 A 6,3 ATotal max. absorption applied (C30) 0,64 A 0,96 A 2,6 A 3,9 ATotal max. absorption applied (C40) 0,48 A 0,72 A 2,2 A 3,3 AOperating temperature - 5 + 50 ºCMinimum distance between the <strong>actuator</strong>s of the same frame1,5 mLength of the cables for power supplyOverall dimensions2,2 m200x155x80 <strong>mm</strong>Total thrust <strong>force</strong> (ACK4) 600N 800N 600N 800NTotal thrust <strong>force</strong> (C30) 600N 800N 600N 800NTotal thrust <strong>force</strong> (C40) 700N 900N 700N 900NTotal traction <strong>force</strong> (ACK4) <strong>400</strong>N 600N 600N 800NTotal traction <strong>force</strong> (C30) <strong>400</strong>N 600N 600N 800NTotal traction <strong>force</strong> (C40) 700N 900N 700N 900N


AL24/2_24/5_24/10Power unit for <strong>actuator</strong>s at 24V


Description for technical specificationsThe AL24 feeder supplies low voltage 24V <strong>actuator</strong>s or, if connected to the EVP, it realizes a feeding group for the low voltage 24V <strong>actuator</strong>s.A relay grants high reliability and safety of the motors. The <strong>actuator</strong>’s movement is manually controlled through a double push-button or bya switch. The AL24/2 (4A) and the AL24/5 (10A) may be simultaneously activated by a single control.The AL24/10 (20A) allows to divide the control in two separate zones according to the installation requirements. The feeding unit iscontained in shockproof plastic. CE marked device complying with the following regulations: EEC 89/336, EEC 73/23 and followingamendments.Technical characteristicsAL24/2 AL24/5 AL24/10Power supply voltage230V 50HzOutput voltage24V DC<strong>Max</strong> exit current 4 A 10 A 20 AService typeS1-continuousOperating temperature - 5 + 50°CWeight 2,500 Kg 4,550 Kg 6,750 KgDimensions (<strong>mm</strong>) 200x250x95 200x250x130 200x250x130ACK4 that can be connected 2 pcs 5 pcs 10 pcsC30 that can be connected 3 pcs 7 pcs 14 pcsC40 that can be connected 3 pcs 9 pcs 18 pcsSL60 that can be connected 3 pcs 6 pcs 12 pcsALTF Feeder with batteries buffer-chargedThe system is composed by a stabilized feeder and a couple of batteries, 12 V, connected in series and buffer charged. The unit ensures,in case of power failure, the power supply of the motors connected to the units for control and ventilation TF21/TF24. CE marked equipment,complying with the following directives: EEC 89/336, EEC 73/23 and following amendments.Technical characteristicsALTFPower supply voltage230 V 50Hz.Output voltage24/12 V d.c.<strong>Max</strong> output current 24V16 A<strong>Max</strong> output current 12V 0.2AOperating temperature - 5 + 50 ºCConnectable control unitsSeries TFOverall dimensionsL.230Xh.310X130 <strong>mm</strong>.


TF21/24_TF41/44Control and power units for <strong>actuator</strong>s at 24V and 230V


Description for technical specificationsThe new TF21/24 (24V output voltage) and TF41/44 (230V output voltage) control units are designed to feed and control, the connectedmotors. The <strong>actuator</strong>s may be individually or simultaneously operated when connected to a manual or radio control. With the suitable modelwe can supply the F33 radio control at 433 Mhz or the F27 infrared remote control. If necessary, the receiver of the infrared remote controlcan be installed outside the unit (for example,near the manual controls) up to a max. distance of 5 meters.The radio and remote controls work with sequential step system (opening <strong>–</strong> stop <strong>–</strong> closing <strong>–</strong> stop….).Every push button controls the respective motor. The simultaneous pushing of two buttons opens or closes all the connected motors.The RPR rain sensor (12V), the RW wind sensor and the RL light sensor may be connected to these units. The TF21/24 and TF41/44units are fitted in shock-resistant plastic. CE marked device complying with the following regulations: EEC 89/336, EEC 73/23 and followingamendments.Technical characteristicsTF21 TF24 TF41 TF44TF21R/T TF24R/T TF41R/T TF44R/TPower supply voltage230V~50HzOutput voltage 24V DC 230V<strong>Max</strong> power consumption 15W 45W 300W 1200W<strong>Max</strong> absorbed current 0,36A 1,5A 1,3A 5,2AService type S1 <strong>–</strong> ContinuousPreset forWind/rain/light sensors, manual controlOperating temperature - 5 + 50°CDimensions (<strong>mm</strong>)160x120x75C20 that can be connected 1pc 4 pcs 2 pcs 8 pcsACK4 that can be connected - - 4 pcs 16 pcsC30 that can be connected - 1pc 4 pcs 16 pcsC40 that can be connected - 1 pc 5 pcs 20 pcsSL60 that can be connected - 1pc 4 pcs 16 pcs


EVPWind/Rain Control Unit


Description for technical specificationsThe EVP wind/rain control unit automatically and independently controls and closes the frames in case ofemergency through wind and rain sensors, that is when the preset values have been exceeded. The rain sensor connected to the EVP isthe low voltage RPR heated version (12V). The unit allows the connection of 230V <strong>actuator</strong>s. If a higher number of <strong>actuator</strong>s arenecessary than the standard, the system can be implemented with more motors, by presetting the equipment witha proper powerful relay or by using one or more M5 modules. Every module is controlled by the same wind and rain sensor.An AL24 feeder, preset to receive the motor’s opening and closing pulse from the EVP, is required for the power going to the low voltage24V <strong>actuator</strong>s. CE marked device complying with the following regulations: EEC 89/336, EEC 73/23 and following amendments.Technical characteristicsEVPPower supply voltage230V-50Hz<strong>Max</strong> output power500 W<strong>Max</strong> absorbed current2,2 AService typeS1-continuousPreset forWind/rain sensors, manual control and/or thermostat*Operating temperature - 5 + 50°CDimensions (<strong>mm</strong>)113x107x45C20 that can be connected2 pcsACK4 that can be connected6 pcsC30 that can be connected6 pcsC40 that can be connected9 pcsSL60 that can be connected6 pcs(* not compatible with the C20 <strong>actuator</strong>)


M5Module to Control/Feed 230V Motors


Description for technical specificationsThe M5 wind/rain unit automatically and independently controls the emergencies through wind and rain sensors, closing and opening thewindows according to the processed impulses.The module is set for:• Five outputs for the <strong>actuator</strong>s• Single control of every exit• The simultaneous control of all exitsThe rain sensor connected to the M5 is the low voltage RPR heated version (12V).The M5 is contained inshockproof plastic. CE marked device complying with the following regulations: EEC 89/336, EEC 73/23 and following amendments.Technical characteristicsM5Power supply voltage230V-50Hz<strong>Max</strong> output power per exit370 W<strong>Max</strong> output current per exit1,6 AFeeding exits 5Service typeS1-continuousPreset forWind/rain sensors, manual control or thermostat*Operating temperature -5 + 50°CDimensions160x120x75 (<strong>mm</strong>)C20 that can be connected2 pcsC30 that can be connected5 pcsC40 that can be connected6 pcsACK4 that can be connected5 pcsSL60 that can be connected5 pcs(* not compatible with the C20 <strong>actuator</strong>)


AC8MEM/ALPCU32AC8_PCU32_MEM/ALModular surveying units of control and detection


Description for technical specificationsThe AC8 and the PCU32 represent a modular control and surveying system for the evacuation of smoke and heat and to control climaticvariations such as rain and wind. The module system has been designed to allow the customer great flexibility to implement and to programthe system according to specific requirements.The AC8 control unit can be connected up to a max of 31 units by means of a RS485 serial line. The AC8 can be employed in threedifferent application systems:• SINGLE: only one AC8 unit to control one single area (connection of 24V voltage motors for max. 16A)• MULTIPLE: more than one units, to control various areas simultaneously (max 31)• COMBINED MULTIPLE: to control more areas from one single point (many AC8 units and 1 PCU32 display).The PCU32 module, equipped witn a LCD display, displays and monitors the status of all the AC8 control units connected to it and controlthem in single or multiple way. It has the buttons for the general co<strong>mm</strong>and and the matrix to display the status of the peripheral modulesof each zone.This innovative system allows to place the AC8 module close to the motors to control. Each system’s configuration can be further implementedwith the MEM/AL optional module that allows the connection of 24V motors for max. 16A. It just feeds the motors while the AC8 operatesthem. A wide choice of accessories, such as electric sirens, flashing lights and automatic dials can be connected to the AC8 and the PCU32units. The alarm caused by smoke, gas and temperature sensors is prior to every other function. Each MEM/AL module is supported bya feeder and batteries; the connection between control unit and MEM/AL module does not need particular wiresbut a standard cable with minimum diameter. The AC8 control unit can work also with 230V motors: if controlled by the M5 module theycan be used for ventilation. All detectors (wind/rain/smoke/gas, etc. sensors) can be connected to the M5, that independently processesthe emergency and operates the window. A battery pack at 24V and buffer charged ensures the power supply to the connected safetysensors for 72 hours avoiding any power loss and useless long wiring costs. The feeding unit is contained in shockproof grey plastic, withIP55 protection rating. CE marked device complying with the following regulations: EEC 89/336, EEC 73/23 and following amendmens.Technical characteristicsAC8MEM/ALPower supply voltage230V-50HzOutput voltage24V DC<strong>Max</strong> absorbed current 0,22A 0,3AService typeS1-ContinuousPreset forWind/rain/smoke sensors, manual switchOperating temperature 5 + 50°CDimensions (<strong>mm</strong>) 320x360x140 225x315x190C20 that can be connected 32 pcs 32 pcsC30 that can be connected 12 pcs 12 pcsC40 that can be connected 14 pcs 14pcsACK4 that can be connected 8 pcs 8 pcsSL60 that can be connected 10 pcs 10 pcs


RW - RPR/RPR2RF811RF813PM1_PM2_PM3EARF811_RF813_PM_EARW_RPR/RPR2


RW Wind Sensor_RPR/RPR2 Rain SensorThe wind sensor, connected to TF21, TF24, EVP, M5 and AC8, is a device that controls the automatic closure of windows when the windspeed exceeds the preset defined value. The RW is contained in weatherproof plastic, with rotating blade system to catch the wind speed.As the wind sensor, the rain sensor must be located outside, exposed to rain.The RPR low tension version (12V) may be connected to the TF21, TF24, EVP and M5 control units; the RPR2 version (230V) may beconnected to the AC8 and TF40. They automatically close windows when the comb sensor is wet; as they are heated, they dry off quicklyand are insensitive to fog, ice, dew and damp.RF811 Smoke DetectorThe RF811 is an optic smoke sensor for indoor smoke detection. It can be connected to the AC8 unit in systems for smoke evacuation.UNI EN54 regulated, it secures high reliability and is protected against false alarms.RF813 Temperature DetectorThe RF813 analogical temperature detector reacts i<strong>mm</strong>ediately to rapid increases in temperature.It can be connected to the AC8 control unit in systems for smoke evacuation and is UNI EN54 regulated.PM1_PM2_PM3 KeyboardsPM keyboards control one or more <strong>actuator</strong>s. Designed to be fitted against the wall, they have 1 or 2 buttons according to the requiredmodel. The box is in shockproof plastic and is equipped with a 10A double switch button with 6 clamps, and a Ø5x20fuse block.EA Emergency ControlThe EA is a manual control device that creates an alarm state when the glass is broken and activates the windowopening. The push button consists of 2 contacts: one is N.A: (normally OPEN) and the other one is N.C. (normally CLOSED).The red external colour of the box responds to the standard safety rules and is IP55 rated.