H 2 SMODEL <strong>2280A</strong>Four-ChannelH 2 S <strong>Gas</strong> <strong>Monitor</strong>GENERAL MONITORSProtection for life.Features• Continuous diffusion, solid-statesensor• High visibility LED status indicators• Adjustment-free calibration• Low power consumption• Wide variety of relay options• Two year warrantyBenefits• Stable operation over wide ambienttemperature and humidity ranges• Provides visual indication of fault andalarm status at the detector location• Lower calibration costs• Lower operating costs• Provides choice to meet specificcustomer requirements• User protectionDescriptionApplicationsThe <strong>Model</strong> <strong>2280A</strong> is a four-channel system specificallydesigned for continuous monitoring of Hydrogen Sulfide(H 2 S) gas in the ppm (parts-per-million) range. The<strong>2280A</strong> controller is a microprocessor-based instrument,which features recent advancements in electroniccircuitry and packaging techniques.The system consists of four remote sensing assembliesand a solid-state controller. The controller consists offour independent channels, each having its own controlcircuitry. The sensors are monitored independently (i.e.they are not scanned, nor are the signals summed).User interfaces are provided so that the operator mayinterpret and direct the <strong>Model</strong> <strong>2280A</strong> in the performanceof its various functions. User interfaces consist of adigital display, status indicators, a mode button and areset button. The digital display provides the user withthe gas concentration at the sensor site, fault diagnosticcodes, calibration prompts and setup parameters.The controller should be mounted in a weatherprotected non-hazardous area. Several GMIaccessories are available for panel, wall or 19-inch rackinstallation. For hazardous areas an explosion proofhousing is available for Class I, Division 1, Groups Cand D.• Compressor Stations• Drilling Platforms and Rigs• Fuel Loading Facilities• <strong>Gas</strong> and Oil Production Platforms• <strong>Gas</strong> Turbines• LNG Processing and Storage• Oil Well Logging• Solvent Vapors• Wastewater Treatment Plants


H 2 SMODEL <strong>2280A</strong>System SpecificationsDigitalReadout:Accuracy:0-20, 0-50, 0-99 ppm±2 ppm or 10% of applied gas,whichever is greaterElectricalClassification: General purpose for mounting innon-hazardous areas, indoors.Warranty:Approvals:Two yearsCSAEnvironmental SpecificationsTemperatureRange:StorageTemperature:Humidity:32°F to 140°F (0°C to 60°C)-4°F to 149°F (-20°C to 65°C)15-95%, non-condensingMechanical SpecificationsMounting:Dimensions:Weight:Panel or wall4.0" W x 6.9" H x 11.5" D(102mW x 175mmH x 292mmD)6.2 lbs. (2.86 kg)Electrical SpecificationsPower:Output:AlarmCircuits:StatusIndicators:105-130 VAC (205-255 VACoptional), 50-60 Hz, 22-30 VDC, 9watts nominal per channel(117 VAC)Analog 4-20mA (300 ohm loadmax.) Accuracy ±5%, 1.5-20mA4A/117 VAC, resistiveAO - Analog output malfunctionSE - Sensor malfunctionHI - High line voltageLO - Low line voltageStandardConfiguration: <strong>2280A</strong>-1-1-1-01-1-4(110 VAC / 24 VDC, commonrelays/alarms, latch alarm, nonlatchwarn, de-energized, 100 ppmstandard sensor, 99 ppm meterscale, 4-active channels)Sensor SpecificationsType:Continuous diffusion, adsorptiontypeTemperatureRange:Standard Sensor: -65°F to +167°F(-55°C to +75°C)High Temperature Sensor to +195°F (90°C)FM Approved: -40°F to +140°F(-40°C to +60°C)ResponseTime:Zero Drift:Repeatability:Life:T 50 < 1 minute with full-scale gasapplied (screen)T 50 < 2 minutes with full-scale gasapplied (sintered)Less than 5% per year±2 ppm or 10% of reading,whichever is greater3 to 5 years, normal serviceElectricalClassification: FM and CSA, Class I, Division 1,Groups B, C and D;ATEX and GOST, Ex ds IIC T6Specificity:Warranty:H 2 S specificTwo yearsCable Length: Four conductor cable. Maximumlength of cable betweencontroller and sensor assemblywith loop resistance of 20 ohmsNOTE: Shielded cable isrecommendedWire Size LengthAWG (Meters) (Feet)14 1,029 3,37516 686 2,25018 411 1,35020 274 900Specifications subject to change without notice.Represented by:Publication #: DS-<strong>2280A</strong>-B0806General <strong>Monitor</strong>sWorldwidewww.generalmonitors.comLake Forest, CA26776 Simpatica CircleLake Forest, California, 92630Tel: +1-949-581-4464Fax: +1-949-581-1151email: info@generalmonitors.comHouston, TX9776 Whithorn DriveHouston, Texas, 77095Tel: +1-281-855-6000Fax: +1-281-855-3290email: gmhou@generalmonitors.comIrelandBallybrit Business ParkGalwayRepublic of IrelandTel: +353-91-751175Fax: +353-91-751317email: info@gmil.ieSingaporeNo. 2 Kallang Pudding Road#09-16 Mactech BuildingSingapore 349307Tel: +65-6748-3488Fax: +65-6748-1911email: genmon@gmpacifica.com.sgUnited Arab EmiratesP.O. Box 61209Jebel AliDubaiUnited Arab EmiratesTel: +971-4-8815751Fax: +971-4-8817927email: gmme@emirates.net.aeUnited KingdomHeather CloseLyme Green Business ParkMacclesfield, CheshireUnited Kingdom, SK11 0LRTel: +44-1625-619583Fax: +44-1625-619098email: info@generalmonitors.co.uk

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!