<strong>COXARTIS</strong>instrument set for arthroscopy of the hip by MiehlkeInstruments for accessAccess instrument setStable puncture cannulas allow directpassage through all soft tissue structuresfor the primary access to the jointunder X-ray control and the creation ofother access portals under endoscopiccontrol.The semi flexible guide wires made ofNitinol (Ø 2 mm) are introduced throughthe inner lumen of the puncture cannulasinto the joint and serve as a bluntguide rail for the introduction of all cannulatedinstruments.As the first dilator, the cannulated rodexpands the access portal to the jointover the guide wire. The trocar sleevesof the arthroscope can be introduced directlyover this rod.The semi dish shape of the guide tubeis used as a guide channel for introducinginstruments. This can be introducedinto the joint either via its cannulatedobturator or via a dilator (blue).Supporting instrumentsPuncture cannula with inner needle,set of 2, Ø 2.65 mm,capacity 2.0 mm,WL 180 mmGuide wire, flexible, set of 2Ø 2.0 mm, WL 450 mmRod, cannulatedØ 4.0 mm, capacity 2.0 mm,TL 325 mmGuide rodØ 4.0 mm, TL 325 mmGuide tube, slottedØ 8.6 mm, inner Ø 7.0 mm,WL 120 mmObturator, cannulatedcapacity 2.0 mm8917320188915340208915320408863.75891237012891232070Dilation systemDilation systemThe user-friendly dilation system consistsof three colour-coded "one-step" dilators,each with a different diameter, that are introducedinto the hip joint one after the otherstarting with the smallest diameterusing the ergonomic handpiece attachment.Dilatorcapacity 2.0 mm,TL 220 mmØ 5.0 mm 891532050Ø 7.0 mm 891532070Ø 9.0 mm 891532090Handpiece attachment 8915300002


<strong>COXARTIS</strong>instrument set for arthroscopy of the hip by MiehlkeArthroscopyTelescopes, short versionPANOVIEWtelescopeTrocar sleeve for telescope, short versionArthrolution trocar sleevewith 2 swivel taps,Ø 6.0 mm, WL 145 mmTrocar, cannulatedcapacity 2.0 mm30°, Ø 4.0 mm,WL 175 mm45°, Ø 4.0 mm,WL 175 mm70°, Ø 4.0 mm,WL 180 mmContinuous irrigation arthroscope sleeve for telescope, short versionArthrolution trocar sleeveØ 5.3 mm, WL 145 mmOuter sheath with two swivel tapsØ 6.3 mm, WL 130 mm8880.5438880.5448880547891231260389123407389123125338912300633arthroscopesThe Arthrolution trocar sleeves wereshaped specially for atraumatic use inthe joint in conjunction with a PANO-VIEW telescope with a 70° angle ofview. Telescopes with a 30° or a 45°angle of view can also be used. Amaintenance-free click locking mechanismguarantees simple, safe and fastconnection of the telescopes in the trocarsleeves.Cannulated trocars allow direct introductionof the arthroscopes into thejoint via the guide wire.A new continuous-irrigation arthroscopewas developed to optimise the view inthe joint. Balanced continuous irrigationand suction allow the joint to be irrigatedquickly and guarantee an excellentview.Longer arthroscopes are also availablefor obese patients.Trocar, semi-blunt 891234052Telescopes, long versionPANOVIEWtelescopeTrocar sleeve for telescope, long version30°, Ø 4.0 mm,WL 255 mm70°, Ø 4.0 mm,WL 258 mm891134030891134070Arthrolution trocar sleevewith 2 swivel taps,Ø 6.0 mm, WL 215 mm8912312607Trocar, cannulatedcapacity 2.0 mm8912340773


<strong>COXARTIS</strong>instrument set for arthroscopy of the hip by MiehlkeAn adapter allows the use of telescopeswith different angles of view during theoperation and the transfer of the cameraunder sterile conditions.Accessories for trocar sleeves and telescopesAdapter, autoclavable 8580.91Stopper 89101.0000Irrigation cannulaThe large-lumen, atraumatic irrigationchannel is used for the efficient aspirationof particles and foreign bodies fromthe hip joint and can be introducedin conjunction with a Ø 7 mm dilator(891532070).Irrigation cannulaIrrigation cannulaØ 8.0 mm, capacity 7.0 mm,WL 168 mm891737080Manual instrumentsSpecially shaped curettes with ergonomichandpieces for effective removaland smoothing of bone, remnants ofcartilage and calcium deposits.Manual instrumentsWCurette,squareWidth W = 4.5 mm,WL 170 mm, angled,distal tip curved upwards,one side sharpWidth W = 6.0 mm,WL 170 mm, angled,distal tip curved upwards,one side sharp891632245891632260ØCurette,roundCurette ring Ø 5.5 mm,WL 170 mm, angled,distal tip curved upwards,one side sharpCurette ring Ø 7.0 mm,WL 170 mm, angled,distal tip curved upwards,one side sharp891631255891631270Graduated microfractors with tips at avariety of angles for microfracture ofcartilage defects with ergonomic handpieces.MicrofractorWL 170 mm15° curved 89163152130° curved 89163302145° curved 89163452135° S-shaped 89163352260° curved 89163602160° S-shaped 89163602280° curved 8916380214


<strong>COXARTIS</strong>instrument set for arthroscopy of the hip by MiehlkeArthroscopyManual instrumentsManual instrumentsHHooked probeWL 150 mm, graduated in steps of2.5 mm, height H = 4.5 mm891534515Extended hooked probe, graduated forpalpation and measuring.Rasp for debriding and removing bone.Rasp, convexWL 175 mm, distal width 4.5 mm89160.3002Banana knifeWL 125 mm8436.251Banana knife for incision of the jointcapsulePunchesPunchesJaws curvedupwards891432102Sharp punches with adapted length andvarious degrees of bend and angleused to resect dense tendinous and ligamentousstructures.ARTHROlinepunchØ 4 mm,WL 180 mm,height of jaws1.6 mmcurved left, jawscurved upwardscurved right, jawscurved upwards891432101891432103standard, shaftcurved upwards8914321225


<strong>COXARTIS</strong>instrument set for arthroscopy of the hip by MiehlkeGrasping forcepsForcepsThe atraumatic grasping forceps canbe used to grasp and remove foreignbodies and remnants of bone.Atraumatic grasping forceps (modular)Ø 5 mm, WL 240 mmcomprising:Inner section (8392.181), sheath(8392.913), convenient handpiecewithout HF and locking mechanism(8393.0001)83921811Reusable cutting instruments andburrsCutting instruments and burrsThe cannulated resectors with adaptedlength can be placed in the joint over aguide wire. The optimised cutting propertiesalso allow resection of densetendinous and ligamentous tissue.ResectorØ 4.5 mm, WL 200 mmwith distal guide holefor Ø 2 mm guide wire899732004Oval and round burrs allow effective resectionof bone.Aggressive curved resector, convexØ 4.5 mm, WL 200 mm899732254The transponder integrated in the cuttinginstruments and burrs automaticallysets the ideal tool parameters on thePowerDrive ART1 control unit and registersthe application time for each individualtool.Aggressive curved resector, concaveØ 4.5 mm, WL 200 mmAggressive resectorØ 4.5 mm, WL 200 mmwith distal guide holefor Ø 2 mm guide wireHooded round burrØ 4.5 mm, WL 200 mm,distal protection shortened by 2 mmOval burrØ 5.5 mm, WL 200 mm,distal protection shortened by 2 mm8997322648997323348997325048997325556


<strong>COXARTIS</strong>instrument set for arthroscopy of the hip by MiehlkeArthroscopyPowerDrive ART1PowerDrive ART1230 V a.c.50/60 Hz100 V a.c.50/60 Hz2304.00112304.0021Powerful shaver handpieces with a maximumworking speed of16000 rpm as well as drilling and sawingtools can be connected to the universalmotor system PowerDrive ART1.PowerDrive ART1 setcomprising:110 V a.c.50/60 Hz2304.0041You will find more information on thePowerDrive ART1 in the separate brochure!PowerDrive ART1generator, CAN-Busconnecting cable115 V a.c.50/60 Hz2304.0061(103.701),power cable (2440.03)120 V a.c.(USA)2304.007150/60 Hz127 V a.c.50/60 Hz2304.00121240 V a.c.50/60 Hz2304.00141Footswitch 2304.901Power Stick M5/0without keypad89955.0000Power Stick M5/3with key pad89955.0003Connecting cable 8564.8517


spirit of excellenceM E D I C A LV E T E R I N A R YI N D U S T R I A LSubject to change without notice.Printed on paper based on cellulose which has been bleached without the use of chlorine.RICHARD WOLF GmbH · 75434 Knittlingen · PF 1164 · Telephone +49 70 43 35-0 · Telefax +49 70 43 35-300 · GERMANY · info@richard-wolf.com · www.richard-wolf.comB 764.VI.09.GB.1AUSTRIA · BELGIUM / NETHERLANDS · FRANCE · GERMANY · INDIA · U.A.E. · UK · USA