<strong>Highly</strong> <strong>Accelerated</strong> <strong>Stress</strong> <strong>Test</strong> <strong>System</strong>(<strong>HAST</strong> Chamber)CAT.NO.E96160-X702


Creates temperature, humidity,and pressure environments toIEC60068-2-66 standard.Humidity resistance evaluation tests for electronic componentsCustomers require test results that correlate accurately tothose from the field in a minimal amount of time.The <strong>Highly</strong> <strong>Accelerated</strong> <strong>Stress</strong> <strong>Test</strong> Chamber EHS Seriesoffer high performance, functionality and ease of use,and are compliant with the international IEC60068-2-66 standard.Many convenient functions and safety features are included for bias testing.


UtilityEven greater convenience and safety.Easy program settingProgram capacity of 10 patterns with 30steps per pattern. Simple operation usingup and down keys for program setting,as well as adjustment of temperature,humidity and time values.Safe and reliable doorThe system employs a button operatedautomatic door locking mechanism.It prevents the door from being openedwhile the test chamber is pressurized.Automatic humidifyingwater supply systemAt the start of testing, the humidifyingwater needed for that test is automaticallytaken from a water tank. A slit onthe front side allows the remainingamount of water in the tank to bechecked at a glance.Protection measures forspecimenStandard equipment includes a specimenpower supply control terminal, whichoutput contact signals to allow voltageand signals to be applied to thespecimen during testing. When aproblem occurs, specimens and chamberare fully protected. Power supply to thespecimen is halted, and protectionmechanisms for preventing overheatingand boil-dry are activated.Instrumentation panelSupports anxiety-free useA variety of protective mechanismsinclude; overheat/overpressure protector,boil-dry protector, detection of watersupply failure and incomplete door-lock,leakage breaker, and temperature sensordisconnection protector. The system alsoemploys an external alarm terminal withan alarm buzzer and lamp. When aproblem occurs, those in the vicinity areimmediately warned.The bottom of the unit includes a water tank and storage spacefor a power supply unit or peripheral equipment.


Control operationComplies with IEC60068-2-66 standard testing while maintainingcompatibility with conventional test methodsConforms to international IEC60068-2-66 standardIEC60068-2-66 is an environmental testing standard of the IEC(International Electro-technical Commission). With ESPEC'sunique wet and dry bulb temperature control function, the EHSSeries meets all requirements for test equipment and testoperation specified in IEC60068-2-66.The EHS Series can also satisfy other test conditions of EIAJED4701, JEDEC and EIA/ JESD22-A110-A as well as IEC.* ESPEC was directly involved in drawing up the IEC60068-2-66 standard, and ourtechnical concepts and measurement data were used in its development.Evaluation of ion migrationWet and dry bulb temperaturecontrol (M type) conforms toIEC60068-2-66 standardWith ESPEC's unique wet and dry bulbtemperature control on M type chamber,temperature and humidity are measureddirectly using a wet and dry bulbtemperature sensor. This ensures highlyprecise temperature and humiditycontrol over the entire testing process,from before testing to the post-testingtemperature decrease or hold process.After testing is complete, the temperatureand humidity are allowed to dropfor a fixed period. In the hold process,the chamber is kept at a fixedenvironment until the door is openedand specimens are removed. This makesit possible to place a specimen in aconstantly controlled temperature/humidityenvironment, and keep it fromdrying after returning to atmosphericpressure.Free from pressure andtemperature shock anddrying of specimens after testExample of the <strong>Highly</strong> accelerated stress test system with the Ion migration evaluation systemIn all control modes, abrupt changes inpressure and temperature after testinghave been eliminated through mechanismsfor gradual depressurization, andair/water discharge. This preventsvaporization of moisture contained inthe specimen, and provide accurate testresults in correlation to the field.


Control operationControl functions to enable useof previous dataThe control mode can be switched tomatch previous data.M type:Wet and dry bulb temperature controlUnsaturated controlWet saturated controlStandard type:Unsaturated controlWet saturated controlThree modes of operation controlWet and dry bulb temperature control (M type) +100Gradient<strong>Test</strong> periodChamber temperatureWet bulb temperatureGradientChamber pressure0.010MPa(Gauge)Exhaust valve openedIn hold process The temperature and humidity gradientbefore and after testing can be controlled. After testing is complete and chamberpressure reaches 0.010MPa (Gauge), onlyair is discharged; humidifying water isretained. In the hold process, temperature andhumidity inside the chamber are maintainedat the specified level. (+50 to+95/75 to95%rh)Unsaturated control (humidifying water temperature control) +10030<strong>Test</strong> periodChamber temperatureHumidifying watertemperatureChamber pressure0.010MPa(Gauge)Exhaust valve openedHumidifying waterdischarge During temperature heat-up when condensationcan easily occur on the reverse sideof the specimen, the temperature of thehumidifying water automatically increaseswhile keeping it 30 lower than thechamber temperature.After testing is complete, the chamber is leftto cool and depressurize naturally untilchamber pressure reaches 0.010MPa(Gauge). Then both air and water aredischarged.Wet saturated control +100<strong>Test</strong> periodChamber temperatureHumidifying watertemperatureChamber pressure0.010MPa(Gauge)Exhaust valve openedChamber temperature is controlled througha humidifying heater.(chamber temperature = humidifying watertemperature)After testing is complete, the chamber is leftto cool and depressurize naturally untilchamber pressure reaches 0.010MPa(Gauge). Then only air is discharged;humidifying water is retained.


SPECIFICATIONSModel EHS-211(M) EHS-211MD EHS-221(M) EHS-221MD EHS-411(M) EHS-411MD<strong>System</strong>Single vessel typeControlmethod<strong>System</strong>Temperature and humidity settingControlFixed value continuous temperature and humidity control; program operation;humidity control when temperature is rising or falling (M/ MD type)Direct setting of temperature and relative humidityPID control, SSR drive systemPower supply 200V AC 150/60Hz, 220V AC 150/60Hz, 230V AC 150Hz *Pressure vessel type Small pressure vessel (as specified in the Japanese Enforcement Order of Industrial Safety & Health Law, item 6, Aritcle 1)Total load currentNoise level200V220V230V15.0A 30.0A 20.0A 40.0A 15.0A 30.0A14.0A 28.0A 18.5A 37.0A 14.0A 28.0A13.5A 27.0A 17.5A 35.0A 13.5A 27.0Abelow 46dB below 50dB below 46dB below 50dB below 46dB below 50dBTemperature control range 105.0 to 142.9 (221 to 289.2 F) 105.0 to 162.2 (221 to 324 F)Unsaturated controlHumidity control rangeTemperature and humidity fluctuationTemperature uniformityHeat up and pressurization time(at RT23)00.196MPa (Gauge)Approx. 30 min.75 to 100%rhPressure range 0.020 to 0.196MPa (Gauge) 0.020 to 0.392MPa (Gauge)0.5/ 3%rh0.5 at 100%rh, 0.7 at 75%rh00.196MPa (Gauge)Approx. 60 min.00.392MPa (Gauge)Approx. 45 min.PerformanceWet saturated controlWet and dry bulb temperature control (M type)Hold process Temp. pull-down <strong>Test</strong> process Temp. heat-upTemperature control range 105.0 to 132.9 (221 to 289.2 F)Pressure range0.020 to 0.196MPa (Gauge)Temperature fluctuationTemperature uniformityHeat up and pressurization time(at RT23)00.196MPa (Gauge)Approx. 45 min.00.196MPa (Gauge)Approx. 60 min.00.196MPa (Gauge)Approx. 75 min.Temperature control range 105.6to 142.9 (221 to 289.2 F)Humidity control range75 to 95%rhHeat up and pressurization time(at RT23)Humidity control rangePressure rangeTemperature and humidity fluctuationTemperature uniformity00.196MPa (Gauge)Approx. 90 min.75 to 98%rh0.5/ 3%rh0.5 at 98%rh, 0.7 at 75%rhTemperature control range 50.0 to 95.0 (112 to 203 F)Temperature pull-down time(at RT23, nospecimen)From 142.9/ 75%rh to 85.0/ 85%rh Approx. 120 min.Temperature control range 50.0 to 95.0 (112 to 203 F)Humidity control range75 to 95%rh105.0 to 151.1 (221 to 304 F)00.392MPa (Gauge)Approx. 60 min.105.0 to 151.1 (221 to 324 F)00.392MPa (Gauge)Approx. 75 min.Temperature control range 105.6to 142.9 (221 to 289.2 F) 105.0 to 162.2 (221 to 324 F)Wet-bulb wick0.50.5From 162.2/ 75%rh to85.0/ 85%rh Approx. 120 min.Can be used continuously for about 200 hours (with no specimen: 162.2/ 75%rh)* This equipment is in compliance with the requirements of the European Community Directives. (CE Marking)0.020 to 0.392MPa (Gauge)0.020 to 0.196MPa (Gauge) 0.020 to 0.392MPa (Gauge)DANGERDo not use specimens which are explosive or inflammable, or whichcontain such substances. To do so could be hazardous, as this maylead to fire or explosion.CAUTIONBe sure to read the instruction manual before operation.


SPECIFICATIONSModel EHS-211(M) EHS-211MD EHS-221(M) EHS-221MD EHS-411(M) EHS-411MDConstructionPressure vessel materialDoor materialExterior materialInsulation materialPressure vesselDoor<strong>Test</strong> areaControl panelWater supply systemStainless steel (SUS-316L)Stainless steel (SUS-316L)Cold-rolled steel plate (SPC. Class1) with melamine resin baked finish (Similar to Munsell 10YR7/1)Glass woolTemperature sensor; heater; specimen signal terminals; fan; fan motor;overheating prevention detector; boil-dry prevention detectorAutomatic locking type (radiating rod system)Specimen rack and 2 rack holders (per chamber)Temperature and humidity indicator; time indicator; key switch; setting keys;process indicator lamps; alarm indicator lamps; door open/ close keyAutomaticWater supply amount (at start) 1L1.5L1LOtherAir outlet valve; air inlet valve; drain filter; drain valve; air lead-in pump; water supply pump; water supply valveAccessoriesTemperature and humiditycontrollerDigital setting and displaySpecimen signal terminals Connector type, 12-pin (125V AC/DC 1A)Pressure gauge (Bourdon type)Communication functionScale: 0.1 to 0.4MPa (Gauge)RS-485Scale: 0.1 to 1MPa (Gauge)Internal capacity of test area(L)18 182 46 462 18 182DimensionsInternal dimensions of test area(mm)Outer dimensions (mm)Weight (kg)W255H255L318(W10H10L12.5inch)W355H355L426(W14H14L16.8inch)W255H255L318(W10H10L12.5inch)W640H1483D850 W760H1795D1000 W740H1553D1000 W860H1795D1000 W640H1483D850 W760H1795D1000(W25.2H58.9L33.5inch) (W29.9H70.7L39.4inch) (W29.1H61.1L39.4inch) (W33.9H70.7L39.4inch) (W25.2H58.4L33.5inch) (W29.9H70.7L39.4inch)Approx. 190 Approx. 350 Approx. 230 Approx. 390 Approx. 190 Approx. 350Dimensions requiredfor installation (mm)W690H1540(W25.2H21.3inch)W810H1850(W31.9H72.8inch)W790H1610(W31.1H63.4inch)W910H1850(W35.8H72.8inch)W690H1540(W25.2H21.3inch)W810H1850(W31.9H72.8inch)TEMPERATURE AND HUMIDITY CONTROL RANGE TEST PROCESS0 0.020 0.098 0.196 0.294 0.392Pressure MPa(Gauge) HOLD PROCESS10010090Relative humidity (%rh)90807060Relative humidity (%rh)80706050100 110 120 130 140 150 160 170Chamber temperature ()5040 50 60 70 80 90 100Chamber temperature ()EHS-211(MMD)221(MMD)EHS-411(MMD)Temperature and humidity indication and control operations for thisequipment are based on Table A. 1, Annex A, IEC Standard 60068-2-66.Humidity range is from 75% to 98% rh for wet and dry bulb control.


MODELEHS- 255 (10)Shelf holder69.5(2.7) INSTRUMENTATION SPECIFICATIONProgram controlNo. of patternsNo. of stepsControlProgram settingMax. time setting1030 steps/ patternRamp, constant settingLoop, skip, end command*Total 999.9hrs per pattern*Time signals can be set for each step when equipped with time signal (option).Each loop command can repeat the specified steps up to 99 times.TEST AREA DIMENSION DIAGRAMEHS-211MMD 411MMD296 (11.7)(Shelf 288)Units: mm (inch)22 (0.9)SAFETY DEVICES Overheat protector Boil-dry protector Overpressure prevention switch Power failure default circuit Leakage breaker Safety valve Temperature sensor disconnection alarm Air-circulating fan/motor rotation alarm Wet-bulb wick dry alarm Door lock alarm Water suspension relay External alarm terminal Specimen power supply control terminalACCESSORIESEHS211M 221M 411M Shelveslarge1, small1EHS-211(M)411(M) large : 248 W288 Dmmsmall : 229 W288 DmmEHS-221(M)large : 348 W396 Dmmsmall : 285 W416 Dmm Fuse (250V 3A) 2 Plug for external alarm terminal andspecimen power supply control terminal 2 Cable clamp 1 Wet-bulb wick (for type M) 50 Portable water tank 1(10L polyethylene tank) Brush 1 Water drain hose nipple 1 Instruction manual 144(1.7)EHS-221MMD355 (14)284 (11.2)Shelf holder118.5(4.7)44(1.7)404 (15.9)(Shelf 396)(Shelf 416)22 (0.9)Front viewRight side view(cross-section)EHS-211MD221MD411MD Shelveslarge2, small2EHS-211MD411MD large : 248 W288 Dmmsmall : 229 W288 DmmEHS-221MDlarge : 348 W396 Dmmsmall : 285 W416 Dmm Fuse (250V 3A) 4 Plug for external alarm terminal andspecimen power supply control terminal 4 Cable clamp 2 Wet-bulb wick (for type M) 100 Portable water tank 1(10L polyethylene tank) Brush 1 Water drain hose nipple 1 Instruction manual 1


OPTIONSPaperless recorderRecords temperature, humidity andpressure inside the chamber. Additionalinputs may also be recorded.Temperature range: 0 to 200Humidity range: 0 to 100rhPressure range:0.1 to 0.5MPa (Gauge)Number of inputs (Initial setting):Temperature 1Humidity 1Pressure 1(3 more channels can be turned ON)Data saving cycle: 5 secExternal recording media:CF memory card (32MB)Language support: ENG, JPN, CHNAdditional specimen signal terminalsEHS-211(M)411(M)12pins (6ch*)up to 4 setsEHS-211MD411MD12pins (6ch*)up to 4 sets per chamberEHS-221(M)12pins (6ch*)up to 5 setsEHS-221MD12pins (6ch*)up to 5 sets per chamber* The numbers of channels given are forconfigurations with two I/O systems.Teflon-coated shelvesStandard shelves (large, small) withTeflon coating.Specimen basketsType A: 150W50H150DmmType B: 100W50H200DmmType C: 95W20H 95DmmTemperature, humidity and pressure recorderRecords: <strong>Test</strong> area temperature<strong>Test</strong> area relative humidity<strong>Test</strong> area pressureRecorder scale plate:0 to 200/ 0 to 100%rh0.1 to 0.5MPa (Gauge)Time signalPaperless recorder Portable typeContact output specificationsOperation: on/ off at each stepNumber of channels: 2EHS-221Standard 12 pinsOptional 12 pins5 setstotal 72 pinsAntiseismic braceUsed to fit chamber onto the floor.Communication functionEnables management of chamberoperationE-BUSRS-232C* Select one other than standard RS-485.Communication cableRS-485E-BUSRS-232C5, 10m5, 10m1, 2, 4mSome photographs listed in this catalog contain Japanese display.


http://www.espec.co.jp/englishHead Office3-5-6, Tenjinbashi, Kita-ku, Osaka 530-8550, JapanTel : 81-6-6358-4741 Fax : 81-6-6358-5500ESPEC NORTH AMERICA, INC.Tel : 1-616-896-6100 Fax : 1-616-896-6150ESPEC EUROPE GmbHTel : 49-89-1893-9630 Fax : 49-89-1893-96379ESPEC ENVIRONMENTAL EQUIPMENT (SHANGHAI) CO., LTD.Head OfficeTel : 86-21-51036677 Fax : 86-21-63372237BEIJING BranchTel : 86-10-64627025 Fax : 86-10-64627036TIANJIN BranchTel : 86-22-26210366 Fax : 86-22-26282186GUANGZHOU BranchTel : 86-20-83317826 Fax : 86-20-83317825SHENZHEN BranchTel : 86-755-83674422 Fax : 86-755-83674228SUZHOU BranchTel : 86-512-68028890 Fax : 86-512-68028860ESPEC TEST TECHNOLOGY (SHANGHAI) CO., LTD.Tel : 86-21-68798008 Fax : 86-21-68798088ESPEC (MALAYSIA) SDN. BHD.Tel : 60-3-8945-1377 Fax : 60-3-8945-1287ESPEC CORP.NO2E19C03 (The contents of this catalog is as of February, 2007.) Specifications are subject to change without notice due to design improvements. Corporate names and trade names mentioned in this catalog are trademarks or registered trademarks.