Rev. 9 December 15, 2012Rev. 9 December 15, 20122. Doors greater than 3’ wide require 4 hinges.3. 16ga. on all other interior doors.4. Corner joints shall be mitered, interlocked, welded <strong>and</strong> ground smooth.5. Frames shall be template reinforced for hardware 7ga. on hinges, 12 ga. everywhere else.6. Acceptable manufacturers: Ceco, Curries, Steelcraft, or Owner approved equal.7. Use Hospital Stops on inpatient areas, treatment, procedure <strong>and</strong> any other areas whereintegral cove bases are required.08 13 00 Hollow Metal Flush Doors:1. All doors fire rated at 90 minutes or higher shall be hollow metal <strong>and</strong> be UL fire rated<strong>and</strong> meet NFPA 80 st<strong>and</strong>ard2. Doors greater than 3’ wide require 4 hinges.3. Painted hollow metal doors shall be used in cross-corridor <strong>and</strong> double egress situations.4. Exterior: SDI-100 Grade III, 16ga. galvanized faces, seamless edges, R-12, polyurethanecore.5. Interior: SDI-100 Grade II, 18ga. faces, seamless edges with 20ga. stiffeners <strong>and</strong> soundinsulation core.6. Doors shall be template reinforced for hardware 7ga. on hinges, 12ga. everywhere else.7. Acceptable manufacturers: Ceco, Curries, Steelcraft, or Owner approved equal.08 14 00 Flush Wood Doors:1. All doors fire rated to less than 90 minutes shall be flush wood door <strong>and</strong> be UL fire rated<strong>and</strong> meet NFPA 80 st<strong>and</strong>ard.2. Doors greater than 3’ wide require 4 hinges.3. In high cart traffic areas, doors shall have kickplates <strong>and</strong> vinyl door frame guards.4. Doors shall be solid core particle board, premium grade, plain sliced, red oak, bookmatched,5 ply, AWI 1300. Optional use <strong>of</strong> eiDoor Vinyl Clad Interior doors by Eggers ispermissible <strong>and</strong> approved by owner.5. Finished doors shall not contain knots.6. Lead lined doors shall be seven ply, solid particle core with hardwood cross b<strong>and</strong>s <strong>and</strong>lead glued to the core. Lead lined door size <strong>and</strong> lead thickness is dependent on the level<strong>of</strong> radiation protection required. Lead lined frames <strong>and</strong> doors shall be installed accordingto manufacturer’s specifications.7. Doors shall be premachined for hardware <strong>and</strong> prefitted to net size.8. Acceptable manufacturers: Graham, Weyerhauser, Algoma, VT Industries, or Ownerapproved equal.20

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!