Rev. 9 December 15, 2012Typical Application : Pharmacy Department Access Door (Non Pharmacy Areas)StructureCeiling1in conduit sleeveinto JB fromunsecured side <strong>of</strong>doorSJBUTo Card Access Panel½ in flex raceway w/string.¾ in conduit raceway w/string.SPIR / ALMFDSM6inFLCKUURDRKEY48 in AFFSequenceDoor will be monitored <strong>and</strong> alarmed by S<strong>of</strong>tware House system if forced or heldopen.Key switch will provide user arm disarm function <strong>of</strong> door to shunt alarm duringoccupied hours. Red Light indicates “armed” green light indicates “disarmed”Device Rough In RequirementsCard Reader function will be disabled if the key switch is armed.Device Description OpeningJB4sq Junction Box on secure side <strong>of</strong> door. ¾ in sleeve to unsecured side <strong>of</strong> door. Cableswill be routed from the cable pathway in the corridor thru this sleeve into the JB.SSecuredSideDSM½ flex raceway from J-Box into the wall down to a ¾ in opening in frame. 6 in from end <strong>of</strong>door. Coordinate the location on frame <strong>and</strong> drilling with the GC.FFrameJob NumberPIRALMLCKKEY½ flex raceway from secured side <strong>of</strong> room into the wall down to the PIR/ALM location.Provide 4sq box in wall with 1G mud ring horizontal.½ flex raceway from J-Box into the wall down to the door lock location. Coordinate thelocation on frame with the GC.¾ conduit raceway from the RDR to the KS.Provide 4sq box in wall with 1G mud ringvertical.SFUSecuredSideFrameUnSecuredSideRevisionsProjectDocumentsUI <strong>Hospitals</strong> & <strong>Clinics</strong>Safety & Security Card Access St<strong>and</strong>ards<strong>Iowa</strong> City <strong>Iowa</strong> 52242ScaleDate:None4/27/2011Serial NumberDrawn ByCVRDR¾ conduit raceway from un-secured ceiling into the wall down to the RDR location.Provide 4sq box in wall with 1G mud ring vertical.UUnSecuredSideDrawing TypePharmacy Single Door - Level P3 - Prox ReaderCard Access DetailsDrawing Number1.22

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!