Rev. 9 December 15, 2012SECTION 07550MODIFIED BITUMEN MEMBRANE ROOFING (SBS)2. Requirementsa. Ro<strong>of</strong> system is classified by Underwriters Laboratories to meet therequirements <strong>of</strong> Class "A" Fire Resistance.b. Ro<strong>of</strong>ing system is classified by Factory Mutual to meet the requirements <strong>of</strong>FRMRC Windstorm Resistance Classification 1-90 minimum.3. Materials <strong>and</strong> PropertiesB. Related Materialsa. Membrane shall be a reinforced styrene-butadiene - styrene polymer meetingthe minimum requirements <strong>of</strong> CGSB 37-GP-56M.b. Membrane sheet shall be granulated with white mineral aggregate. Granuleembedment loss shall be less than two grams per square foot.c. Base ply shall be a modified asphalt base sheet <strong>and</strong> compatible with thesurface membrane sheet.1. Asphalt primer: Shall meet requirements <strong>of</strong> ASTM D 41. Primer shall be asrecommended by the membrane manufacturer.2. Flashing membrane: Shall be modified bituminous material as recommended <strong>and</strong>furnished by the membrane manufacturer.3. Ro<strong>of</strong> insulation: Reference Section 07220 - Ro<strong>of</strong> <strong>and</strong> Deck Insulation forrequirements.4. Ro<strong>of</strong> Insulation Fasteners: Reference Section 07220 - Ro<strong>of</strong> <strong>and</strong> Deck Insulation forrequirements.5. Ro<strong>of</strong> cement: Shall meet requirements <strong>of</strong> ASTM D 4586 (asbestos-free) <strong>and</strong> berecommended by the membrane manufacturer.6. Loose ro<strong>of</strong>ing granules: Shall meet requirements <strong>of</strong> ASTM D 451 <strong>and</strong> berecommended by the membrane manufacturer. Color shall match color <strong>of</strong> granulatedmembrane sheet. Size shall match size <strong>of</strong> granules on the membrane.7. Nails <strong>and</strong> Fasteners: Non-ferrous metal or galvanized steel, except that hard coppernails shall be used with copper; aluminum or stainless steel nails shall be used withaluminum; <strong>and</strong> stainless steel nails shall be used with stainless steel. Fasteners shallbe self-clinching type or penetrating type as recommended by the manufacturer <strong>of</strong> thedeck material. Nails <strong>and</strong> fasteners shall be flush-driven through flat metal discs <strong>of</strong> notless than 1-inch diameter. Metal discs may be omitted when one-piece compositenails or fasteners with heads not less than 1-inch diameter are used.Modified Bitumen Membrane Ro<strong>of</strong>ing (SBS)UIHC #20X-0XX 07550-8

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!