ls 2200 int base-h 001 - Idamer

ls 2200 int base-h 001 - Idamer

ls 2200 int base-h 001 - Idamer

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

FunctionsModel summary• Determination of the thermal energy given out by aradiator, <strong>base</strong>d on the measured and rated radiatortemperature• Cumulative consumption since the last readingdate• Previous year’s consumption• Remote read out by radio• Adjustable counting start date (if required)• Transfer of the consumption figures to the BaseNetor BaseGate network nodes of the SensusBaseradio system• Tamper protection: Indication on the displayand error message to the central controller uponunauthorized opening of the units* With the option of an optical <strong>int</strong>erface forprogramming on siteSingle sensor measuring principleUnitSensusBase heat cost allocator, compact unitSensusBase heat cost allocator, remote sensor unitDual sensor measuring principleSensusBase heat cost allocator, compact unitSensusBase heat cost allocator remote sensor unitEquipmentModel descriptionBase-H1CBase-H1DBase-H2CBase-H2DMeasuring principleThe SensusBase heating cost distributor is supplied as a single sensor unit and asa dual sensor unit. On delivery the following rating factors are programmed:K cHF = 1,28 K c = 2,50 K Q = 1000 Exp.=1,15On delivery ex works the reference date 31.12. is programmed. If the SensusBaseheat cost allocator is not working with a product scale (only possible for Base-H1C and Base-H1D ), then, before billing, the consumption figure (VW) must becalculated from the reading value (AW) and the K-values (K cHF and K Q )specific to the radiator:Single sensor unit VW = 7,529 * 10 -4 * AW * K Q * K 1,15 cHFDual sensor unit: VW = 3,486 * 10 -4 * AW * K Q * K c1,15DisplayThe content of the display changes cyclically andincludes the following data:Special displaysThe following displays are a<strong>ls</strong>o possible:1 - Present value2 - Display test (flashing)3 - Reference date (date)4 - Consumption figure on the reference date5 - New reference date6 - Error message7 - Rated output of the radiator8 - Kc-value (Display 7+8 only for heat cost allocators with set parameters)9 - Start dateSpecial displaySpecial displayIrDA communication possible again in thefollowing monthUnit operating time of 3650 days exceededBase-HL S <strong>2200</strong> INT • Page 2 / 6

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!