12.07.2015 Views

ls 2200 int base-h 001 - Idamer

ls 2200 int base-h 001 - Idamer

ls 2200 int base-h 001 - Idamer

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Base-HElectronic heat cost allocatorRemote read out heat cost allocator withvarious measuring principa<strong>ls</strong>Electronic unit for allocation of heating costs by registering the heat energy given out by a radiator. Remote radio read out.Available as a single or dual sensor unit.ApplicationThe SensusBase heat cost allocator Base-H is used aspart of the SensusBase remote read out system, whenthe heating costs have to be allocated among severalconsumers <strong>base</strong>d on the actual consumptionThe main areas of application are heating systems witha central heat provision, in which the heating energy ispurchased individually by the consumers.Systems of this type are, for example, used in:• Multiple dwellings• Office and commercial buildings.With regard to the radiator the heat cost allocator is usable with:• Sectional radiators• Tubular radiators• Panel radiators with horizontal and vertical water feed• Radiators with <strong>int</strong>ernal tube register• Convectors• Mean design heating medium temperatures from 35 °C min. to 105 °C max.(depending on the measuring principle)Typical users are:• Private building owners• Housing associations• Building co-operatives• Energy service and billing companies• Real estate managementUK & Ireland EnquiriesSensus Metering Systems11 The Quadrangle, Abbey Park,Romsey, Hampshire SO51 9DL UKT: +44 (0) 1794 526100F: +44 (0) 1794 526101Email: info.gb@sensus.comwww.sensus.comInternational EnquiriesSensus Metering Systems GmbH LudwigshafenIndustriestrasse 16,67063 Ludwigshafen GermanyT: +49 (0) 621-6904-0F: +49 (0) 621-6904-1409Email: info.<strong>int</strong>@sensus.comwww.sensus.comL S <strong>2200</strong> INT• Page 1 of 6


FunctionsModel summary• Determination of the thermal energy given out by aradiator, <strong>base</strong>d on the measured and rated radiatortemperature• Cumulative consumption since the last readingdate• Previous year’s consumption• Remote read out by radio• Adjustable counting start date (if required)• Transfer of the consumption figures to the BaseNetor BaseGate network nodes of the SensusBaseradio system• Tamper protection: Indication on the displayand error message to the central controller uponunauthorized opening of the units* With the option of an optical <strong>int</strong>erface forprogramming on siteSingle sensor measuring principleUnitSensusBase heat cost allocator, compact unitSensusBase heat cost allocator, remote sensor unitDual sensor measuring principleSensusBase heat cost allocator, compact unitSensusBase heat cost allocator remote sensor unitEquipmentModel descriptionBase-H1CBase-H1DBase-H2CBase-H2DMeasuring principleThe SensusBase heating cost distributor is supplied as a single sensor unit and asa dual sensor unit. On delivery the following rating factors are programmed:K cHF = 1,28 K c = 2,50 K Q = 1000 Exp.=1,15On delivery ex works the reference date 31.12. is programmed. If the SensusBaseheat cost allocator is not working with a product scale (only possible for Base-H1C and Base-H1D ), then, before billing, the consumption figure (VW) must becalculated from the reading value (AW) and the K-values (K cHF and K Q )specific to the radiator:Single sensor unit VW = 7,529 * 10 -4 * AW * K Q * K 1,15 cHFDual sensor unit: VW = 3,486 * 10 -4 * AW * K Q * K c1,15DisplayThe content of the display changes cyclically andincludes the following data:Special displaysThe following displays are a<strong>ls</strong>o possible:1 - Present value2 - Display test (flashing)3 - Reference date (date)4 - Consumption figure on the reference date5 - New reference date6 - Error message7 - Rated output of the radiator8 - Kc-value (Display 7+8 only for heat cost allocators with set parameters)9 - Start dateSpecial displaySpecial displayIrDA communication possible again in thefollowing monthUnit operating time of 3650 days exceededBase-HL S <strong>2200</strong> INT • Page 2 / 6


AccessoriesAssembly jig and miscellaneous accessoriesAccessoriesAssembly jigWHZ2.MLSpare lead seal for WHE2 U12102-2004The lead sea<strong>ls</strong> are not included in the delivery specification of the Base HxxSensusBase heat cost allocator except for remote sensor units Base H1D. Thelead sea<strong>ls</strong> have to be ordered separatelyAssembly kitsEach assembly kit includes all available components. The right parts have to beselected for the specific assembly situation. Assembly kits exist for:• Panel radiators• Sectional radiators and tubular radiators• Convectors• Finned radiators• Tubular radiators• Aluminium radiatorsAssembly kit for panel radiatorsComponents Variants Delivery unit Model descriptionHeat conductor Heat conductor 3/1 50 off F12130-2<strong>001</strong>/1Heat conductor 4 50 off F12130-2<strong>001</strong>/4Slotted nut M3 500 off F12102-2019Welding stud M3 x 6 mm 100 off 02/572Welding stud M3 x 10 mm 100 off 02/574Welding stud M3 x 15 mm 500 off F12102-2041Welding stud (Aluminium) M3 x 16 mm 1.000 off F12102-2041/1Shank nut (hexagon) M3 x 3 mm 100 off FZ253-210Shank nut (hexagon) M3 x 6 mm 1.000 off FZ253-200Shank nut (hexagon) M3 x 9,5 mm 100 off FZ253-220Ratchet nut M3 1.000 off FZ253-230Assembly kit for sectional radiatorsComponents Variants Delivery unit Model descriptionHeat conductor Heat conductor 3/1 50 off F12130-2<strong>001</strong>/1Heat conductor Adapter 2/55 mm 25 off F12105-2061Single start slide nut 35 35 mm 50 off FZ253-300Single start slide nut 50 50 mm 50 off FZ253-310Single start slide nut 65 65 mm 50 off FZ253-320Screw M4 x 35 1.000 off F12105/2084Screw M4 x 50 500 off F12105/2085Screw M4 x 70 500 off F12105/2086Depending on the assembly situation the particular heat conductor is to be used with a suitable slide nut.Assembly kit for convectors(remote sensor unit)Components Variants Delivery unit Model descriptionConvector bracket complete(bracket, backing piece, 2 xSlotted nut, pull-off nut) 1 off F12105-1051Welding stud M3 x 6 100 off 02/572Slotted nut M3 500 off F12102-2019The remote sensor has to be fixed on the assembled convector assembly bracket with the pull-off nut.Base-HL S <strong>2200</strong> INT • Page 3 / 6


Assembly kit for aluminium radiatorsComponents Variants Delivery unit Model descriptionHeat conductor Heat conductor 3/1 50 off F12130-2<strong>001</strong>/12 x toggles 50 off FZ253-1602 x cross head screw M3 x 25 500 off F12105-20762 x self tapping screw C 4,2 x 25 C 500 off F10102-2026(instead of toggle)Depending on the assembly variant either the 2 self tapping screws C 4.2 x 25 or two toggles with their M 3 x 25 screws are to be usedTechnical dataMeasuring principle:Single sensor or Dual sensorRange of use 1 ):Single sensor units t min,m = 55 °C, t max,m = 105 °CDual sensor units t min,m = 35 °C, t max,m = 105 °CStart of count:(t Z relates to the determined heating medium temperature)Single sensor unitst Z ≥ 30 °C (for t L = 20 °C) unratedt Z ≥ 28 °C (for t L = 20 °C) ratedDual sensor units t Z - t L ≤ 5 K1 ) Definitions to DIN EN 834t min,mt max,mt Zt Lt mLowest mean design heating medium temperature, for which the heating cost distributor may be used. For single pipeheating systems this is the mean design heating medium temperature of the last radiator in the runHighest mean design heating medium temperature, for which the heating cost distributor may be used.Mean heating medium temperature of the radiator at which the register of the heating cost distributor starts to runReference air temperatureMean heating medium temperatureDimensions (B x H x T):LifeDisplayWeightTransmission frequencyTransmission powerStorage temperature92,5 x 40 x 28 mm10 years plus 15 months reserveLCD, five character with special symbo<strong>ls</strong>120 g868 MHz< 1 mW-25° to +60°CBase-HL S <strong>2200</strong> INT • Page 4 / 6


StandardsHeat cost allocator for registering theconsumption figures of room heating surfaces EN 834Electromagnetic Compatibility, Immunity to<strong>int</strong>erference ETSI EN 301 489 –1 V1.4.1 (2002-08)ETSI EN 301 489 –3 V1.4.1 (2002-08)EN 61000-6-2:2<strong>001</strong>Emitted <strong>int</strong>erference EN 300 220 –1 V1.3.1 (2000-09)EN 300 220 –3 V1.1.1 (2000-09)EN 61000-6-3:2<strong>001</strong>Security of IT equipment EN 60950CE - ConformityDirective 1995/5/EC (R&TTE Directive)Law on radio equipment and Telecommunications equipment (FTEG)Dimensions in mmBase-HL S <strong>2200</strong> INT • Page 5 / 6


SensusBase Documentation summaryThe SensusBase system allows a remote wireless read out of measuring units. To link in further Sensus meters, e.g. for the ResidiaApartment Water Meter, the Base-R Module is used. For the <strong>int</strong>egration of third party system meters with pu<strong>ls</strong>e outlet <strong>int</strong>o the radio system,the pu<strong>ls</strong>e adapter Base-P is available.Unit Type DocumentsSensusBase-SystemData Sheet LS2100 INTHeat meter PolluCom-E/-C Data Sheet LH 1100 INT and LH 1300 INTWater meter Residia... Data Sheet LA 2100 INT, LA 2110 INT and LA <strong>2200</strong> INTL S <strong>2200</strong> INT / <strong>001</strong>-0405 • Technical data subject to change without prior noticeBase-HL S <strong>2200</strong> INT • Page 6 /6

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!