MAINTENANCE○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○The belt tension should be checked at three-monthintervals.Re-lubricable bearings mounted inside the fan sectionhave extended lubrication lines which are mounted onthe outside of the fan panels. The suggested greasinginterval is indicated on a sticker attached to the unit.It is recommended that bearings be lubricated with ahigh quality lithium base grease at intervals indicatedon sticker attached to the unit.Instructions are included on the motor nameplate forlubricating the motor bearings.The filters should be periodically inspected and replacedor cleaned when necessary. Dirty filters reduce the airflow which reduces the capacity of the system. Do notoperate system without filters.All CS 2 Units are Internally IsolatedIsolators are installed and adjusted at the factory.Brackets and bolts tie down the fan and motor assemblyfor shipment. Remove tie down bolts before start-up.Refer to page 4 for clarification.Remove the bolt from bracket to motor support base,then loosen bolts to frame and slide bracket to end ofslot so bracket is not in contact with the motor supportbase. The bracket then acts as a snubber on fan startup.END RAILMOTOR BASE SUPPORT(4) SHIPPING BRACE /SNUBBER(DO NOT DISCARD)Lube inlet vanes and/or damper linkage annually.Check for drain clogging several times a year.Clean coils and drain pans as necessary.Condensate Drain TrapsThe condensate drain trap piping must be properlydesigned to insure the removal of condensate. Incorrecttrapping can hold water in pan causing overflow. Onblow thru units, particularly, system air can escape downthe drain with incorrect trapping.ISOLATORISOLATOR RAILCONDENSATE DRAIN TRAP(AIR SEAL)1¼" PIPE DRAIN CONNECTIONAB(a) On draw-thru units (A) shall be equal to or greaterthan the coil sections negative pressure at operatingconditions.(b) On blow-thru units (A) can be as small as 1" but (B)must equal or exceed the total static pressure inthe coil section.5

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!