12.07.2015 Views

CS2 Central Station Air Handlers.pdf - Dunham-Bush Americas

CS2 Central Station Air Handlers.pdf - Dunham-Bush Americas

CS2 Central Station Air Handlers.pdf - Dunham-Bush Americas

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

SHIPPING MODULES ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○The CS 2 offers flexibility for splitting the unit into as many (or few) shipment modules as desired. However, sizes 240 andlarger are usually too large to allow one piece shipment because unit width exceeds truck width. The CS 2 can be split intomodules at as many section to section joints as desired with the following considerations:1. Wide load shipping costs are required over 102". It is not practical to ship over 144" width. Therefore, the unit mustbe separated to minimize module length (in direction of air flow) and, therefore, shipping cost.2. Installation cost is generally proportional to the number of modules.3. Internal/external connecting brackets are utilized. Therefore, the CS 2 cannot be split between two coil sections,because flanges are not accessible from either direction.The following examples illustrate shipping options and assembled unit length:EXAMPLE: SIZE 320UNIT ASSEMBLY3 PIECE SHIPMENT(Maintain 102" maximum module lengthand standard freight cost)2 PIECE SHIPMENT(Maintain 144" maximum module lengthusing wide load freight cost)COOL-MIXBOXBAGFILTERCOOL-INGMIXBOXBAGFILTERINGCOILCOILHORIZONTALFANHORIZONTALFAN56.00 36.00 24.00 70.0056.00 36.0024.00 70.00Installed unit length = 186.00 Installed unit length = 186.00Assembled length = (nominal section lengths + (1.7)"(number of splits)2 PIECE TRUCK LOADING (Must pay "wide load" premium)Fan & Cooling Coil109.7 x 151.5Mix Box & Bag Filter109.7 x 151.5CS 2 unit sizes 17 thru 65 can be shipped in one piece. The overall length of the requested sections(i.e. filters, mixing box, access section, etc.) determines if the total unit can be shipped in onepiece. Units that exceed twelve (12) feet in direction of airflow will ship in two sections. Thedesign of the CS 2 allows the customer to dictate the number of individual sections of the unit.Consult factory where specific shipping assemblies must be furnished.COMPONENTS & DESIGN—SUBJECT TO CHANGE WITHOUT NOTICE.13

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!