<strong>VOGEL</strong> - <strong>Endsuction</strong> <strong>Pumps</strong>, <strong>Design</strong> <strong>LS</strong>Performance Range:Capacity up to 4.600 m 3 /h (20.250 USgpm)Head up to 170 m (560 feet)Speed up to 1750 min -1 (1750 r.p.m.)Sizes:DN 125 up to DN 600 (5” up to 24”) dischargeSize DN 32 up to DN 150 (11/4”up to 6”)refer to design IC, brochure 7102.1.Bdesign <strong>LS</strong>N, brochure 1200.1.BTemperature:max. 180 o C (350 o F)Casing pressure:up to 16 bar (170/230 psig)For higher casing pressures refer to design <strong>LC</strong>/<strong>LC</strong>P page 6Handled liquids:Clean or slightly contaminated liquids(without bigger solids)Cold and hot waterCondensate and deionateOil brine and acidPaper stock suspensions up to 1,2%Materials:Applications:General industryChemical industrySteel mills and miningSugar industryPulp and paper millsMat. CodeImpellerCasing,Casing CoverWear ringsBearingframeShaftShaft sleeveN<strong>LC</strong>ast Iron0.6025SLBronzeCC480 KDuctile iron0.7040VLNFSFStainless steel1.4408Cast Iron0.6025BronzeCC480 KCarbon steel1.0619Cast iron0.6025Cast iron0.6025Stainlesssteel1.4021Stainless steel1.4021VFStainless steel1.4408VVWWStainless steel1.4408Duplex1.4517Stainless steel1.4408 DuplexDuplex1.45171.4462/1.4517Duplex1.4462Other materials upon request2


<strong>VOGEL</strong> - <strong>Endsuction</strong> <strong>Pumps</strong>, <strong>Design</strong> <strong>LC</strong>, <strong>LC</strong>PPerformance Range:1450 r.p.m, 950 r.p.m, 750 r.p.m.CapacityTotal head [m]Total head [ft]Capacity Q [m 3 /h]<strong>Design</strong> ICP refer to brochures 7300.1.B.7


<strong>VOGEL</strong> - <strong>Endsuction</strong> <strong>Pumps</strong>, <strong>Design</strong> <strong>LC</strong>, <strong>LC</strong>P<strong>Design</strong> <strong>LC</strong>:Foot mounted casing design for operating temperatures up to max. 180 o C (350 o F) / 25 bar(360 psig).<strong>Design</strong> <strong>LC</strong>P:Process design with centerline casing feet for operating temperatures up to max. 210 o C(410 o F) / 25 bar (360 psig).Due to the centerline casing feet and the additional support feet a negative influence on the couplingalignment caused by thermal expansion of the casing at high operating temperatures is avoided.At operating temperatures above 180 o C (350 o F) oil sump cooling of the bearing frames is required.8


<strong>VOGEL</strong> - <strong>Endsuction</strong> <strong>Pumps</strong>, <strong>Design</strong> <strong>LC</strong>, <strong>LC</strong>P● Horizontal single stage endsuction pumps with closed impeller.● <strong>Design</strong> IC with foot mounted casing for operating temperatures up to 180 o C (350 o F).<strong>Design</strong> <strong>LC</strong>P with centerline casing feet for operating temperatures up to 210 o C (410 o F).● Process design, back pull out for easy and safe maintenance. Disassembly of impeller and bearingframe without dismantling of the pump casing and motor possible (spacer type coupling required).● Thrust bearing at drive side (pair of angular contact bearings) for high load capability in bothdirections, roller bearing at pump side.● Solid shaft dimension for low shaft deflection and heavy duty oil lubricated bearings for continuousoperation.● For all stainless version dry shaft design, shaft and threads protected by closed impeller nut and shaftsleeve.● Distance between bearings bigger than impeller overhung.● Shaft sealing stuffing box with internal or external flush or cooled stuffing box. Mechanical seals acc.to EN 12756 (DIN 24960), inner single mechanical seal, double mechanical seals or cartridge seals.9


<strong>VOGEL</strong> - <strong>Endsuction</strong> <strong>Pumps</strong>, <strong>Design</strong> <strong>LS</strong>, <strong>LC</strong>, <strong>LC</strong>PShaft sealing:<strong>Design</strong> <strong>LS</strong>, <strong>LC</strong>, <strong>LC</strong>PStuffing box optional with internalor external flush fortemperatures up to 140 o C (280 o F)<strong>Design</strong> <strong>LS</strong>, <strong>LC</strong>, <strong>LC</strong>PStuffing box with cooling jacketfor temperatures up to 180 o C (350 o F)<strong>Design</strong> <strong>LS</strong>Single mechanical sealacc. to EN 12756 (DN 24960) unbalanced<strong>Design</strong> <strong>LS</strong>, <strong>LC</strong>, <strong>LC</strong>PSingle mechanical sealacc. to EN 12756 (DN 24960) balanced10


<strong>VOGEL</strong> - <strong>Endsuction</strong> <strong>Pumps</strong>, <strong>Design</strong> <strong>LS</strong>, <strong>LC</strong>, <strong>LC</strong>PShaft sealing:<strong>Design</strong> <strong>LS</strong>, <strong>LC</strong>, <strong>LC</strong>PCartridge seal singleOptional single with quench and doubleseals available<strong>Design</strong> <strong>LS</strong>, <strong>LC</strong>, <strong>LC</strong>PSingle balanced mechanical sealin „dead end” configurationfor hot water applications11


ITT Austria GmbHA-2000 StockerauErnst Vogel-Straße 2Telefon: ..43-2266-604Telefax: ..43-2266-65311E-Mail: info.ittaustria@itt.comwww.ittaustria.comLiability of manufacturer and/or supplierThe mentioned limits of operation and/or application are only ageneral information and may not be applied for every case. Thepermitted range of operation and/or application for the specificcase is to be obtained from our acknowledgement of order and/orthe instructions for installation, operation and maintenance, sentwith the goods.Liste 1300.1.B9/2009-e12

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!