12.07.2015 Views

Industrial cooling solutions - Air Bonaita

Industrial cooling solutions - Air Bonaita

Industrial cooling solutions - Air Bonaita

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Technical dataHyperchill LaserModel ICLCooling capacity 1Absorbed power 1Cooling capacity 2Absorbed power 2ControllerCompressorsCompressors/circuitsMax. abs. powerFLALRAExpansion deviceEvaporator005 007 010 015 022 029 039 046 057kW 5,0 6,7 9,5 14,2 21,8 27,8 38,2 45,2 56,4kW 1,4 1,9 2,3 3,4 5,2 5,6 7,7 10,1 12,3kW 4,7 6,2 8,7 13,0 20,6 26,2 36,4 42,9 53,7kW 1,6 2,2 2,6 3,9 6,5 7,1 9,6 13,0 15,3µchiller 2pCO xshermetic pistonshermetic compliant scrolln° 1/1kW 1,5 2,0 2,5 2,9 6,7 7,8 11, 13,7 16,8A 7,5 9,9 5,5 10,0 11,4 14,6 19,2 25,6 27,8A 37 75 28 42 74 99 127 167 198capillarythermostatic valve (MOP)Typecopper-brazed plate evaporatorPressure drop 1kPa 5,3 8,9 23,5 48,5 41,2 36,6 40,1 33,5 45,7FansQuantityn° 1 2 3Max abs. powerkW 0,12 0,12 0,35 0,35 0,78 0,78 0,61 0,61 0,61FLA - 1 fansA 0,57 0,57 0,44 0,44 1,35 1,35 1,15 1,15 1,15Wassermengem 3 /h 2300 1900 4100 3500 6800 9200 12400 12000 17400Pump P30TypeperipheralcentrifugalMax. abs. powerkW 0,37 0,37 0,5 0,5 1,34 1,34 2,28 2,28 2,28FLAA 2,5 2,5 1,7 1,7 2,6 2,6 4,8 4,8 4,8Water flow 1 (nom/max) m 3 /h 0,86/2,4 1,1/2,4 1,6/6 2,4/6 3,7/9,6 4,8/9,6 6,6/18 7,8/18 9,7/18Head pressure 1 (nom/min) m H 2 O 30/6 25/6 30/21 29/21 28/17 27/17 28/22 28/22 27/22Pump P50TypeperipheralcentrifugalMax. abs. powerkW 0,75 0,75 0,75 0,75 2,2 2,2 2,2 2,2 30FLAA 2,1 2,1 2,1 2,1 5,2 5,2 5,2 5,2 6,5Water flow 1 (nom/max) m 3 /h 0,86/2,7 1,1/2,7 1,6/4,9 2,4/4,9 3,7/9,0 6,6/12,5 7,8/12,5 78,/12,5 9,7/12,5Head pressure 1 (nom/min) m H 2 O 58/22 52/22 52/35 50/35 58/38 55/38 48/37 47/37 46/37Dimensions & weightWidth (A)mm 750 750 550 550 760 760 760 760 760Height (B)mm 800 800 1478 1478 1358 1358 1358 1358 1358Depth (C)mm 530 530 980 980 1650 1650 1650 1650 1650Water connections “ 3/4” 3/4” 3/4” 3/4” 1” 1” 1 ¼” 1 ¼” 1 ½”Tank capacityl 30 30 70 70 140 140 210 210 280Weight 3kg 90 110 146 156 259 321 355 375 500Noise levelSound pressure 4dB(A) 52 52 50 50 53 53 52 52 56(1) at water inlet/outlet temperature = 20/15°C, glycol 0%, ambient temperature 25°C. Net <strong>cooling</strong> capacity, without pump heat load.(2) at water inlet/outlet temperature = 25/20°C, glycol 0%, ambient temperature 35°C. Net <strong>cooling</strong> capacity, without pump heat load.(3) weights are inclusive of pallet and refrigerant charge.(4) referred to free field conditions at a distance of 10m from unit, measured on condenser side, 1 m from ground.Power supply: 230V / 1ph / 50Hz for ICL003-005; 400V / 3ph / 50Hz for ICL010-057.Protection class: IP33 for ICL003-005; IP44 for ICL010-015; IP54 for ICL022-057.All models equipped with ecological refrigerant R407C.Correction factors for the calculation of the <strong>cooling</strong> capacityA) Ambient temperaturecorrection factor (f1)B) Water outlet temperaturecorrection factor (f2)C) Glycol (in weight)correction factor (f3)°C 5 10 15 20 25 30 35 40 451,05 1,05 1,05 1,05 1 0,95 0,89 0,83 0,77°C 5 10 15 20 250,72 0,86 1 1 1% 0 10 20 301 0,99 0,98 0,97To obtain the required <strong>cooling</strong> capacity multiply the value at nominal conditions by the above correction factors (i.e. <strong>cooling</strong> capacity = Pxf1xf2xf3, where P is the<strong>cooling</strong> capacity at conditions (1)). Hyperchill Laser, in its standard configuration, can operate up to ambient temperatures of max 45°C and min. 5°C and watertemperatures of max 30°C inlet and min. 0°C outlet. The above correction factors are approximative: for a precise selection always refer to the software selectionprogram.Free your Energy

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!