12.07.2015 Views

Apricus Solar Water Heating System Installation and Operation ...

Apricus Solar Water Heating System Installation and Operation ...

Apricus Solar Water Heating System Installation and Operation ...

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>Apricus</strong> <strong>Solar</strong> Collector <strong>Installation</strong> & <strong>Operation</strong> Manual - USA12. TroubleshootingWARNINGApart from those inspection items specifically outlined as “HOMEOWNER”, anymaintenance or repair must only be completed by Authorized Persons. The solar collectorwarranty may be void if non-Authorized Person attempt to maintain or repair the solarcollector or associated system components. The solar system operates at high pressure<strong>and</strong> high temperature <strong>and</strong> can result in damage to both property <strong>and</strong> personal injury if notcorrectly operated <strong>and</strong> maintained.CL = Specific to Closed Loop DF = Specific to Direct FlowDB = Specific to Drain-BackProblem Cause SolutionPump not ON duringgood solar radiationconditionsPump cycling ON <strong>and</strong>OFF during good solarconditionsPump always ON evenduring minimal solarradiation conditionsPump running at nightFluid dumping frompressure relief valve onpump stationFluid dumping frompressure relief valve ontankTemperature sensors not workingproperlyController settings incorrectController Max Temp setting hasbeen reachedPartial shading of collectorExcessive system flow rateController settings incorrectInsufficient flow rateAir lock in piping systemSensor location too lowController settings incorrectController settings incorrectPoor Sensor ReadingFaulty pressure relief valveFaulty expansion tankExcessive tank temperatureFaulty expansion tank· Check that sensor is installed correctly· Check that sensor wire is not damaged· Check sensor Ohm reading with Ohm to °F chart incontroller manual· Check controller is set to AUTO operation· Check maximum tank <strong>and</strong> collector settings· Check maximum tank <strong>and</strong> collector settings· Check collector location for shading· Adjust restrictor screw on flow meter· Reduce pump speed (select slower speed)· Check if differential (dT function) is correct, dTMin may° °be set too high, reduce to 2 C / 4 F· Check flow gauge for proper flow rate· Adjust restrictor screw on flow meter· Check that all isolation valves are open· (DF/CL) Release air from air vent on highest point· (CL) Purge system of air by following Fill <strong>and</strong>Pressurize procedure described in section 7.9.· T2 sensor (bottom tank) should be slightly above thelevel of the solar flow port. If below the flow port, thepump may run continually even when there is no solarheat.°· dTMin may be set too low. Increase 2-3 especially ifclosed loop system.· (DF) Check that freeze protection setting is correct.Intermittent circulation is freezing conditions is normal.Ensure pipes are well insulated.· (DF) Tank S2 sensor not getting accurate reading· Replace pressure relief valve· (CL) Replace expansion tank on pump station· Check Maxtemp Tank1 setting of controller· Check tank sensor (T2) operation· Replace expansion tank on potable water sideCopyright 2011 – <strong>Apricus</strong> Inc Doc: A7-05.4.1.4-PB-1.9 Page 84 of 126

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!