12.07.2015 Views

Boston - American Association for Thoracic Surgery

Boston - American Association for Thoracic Surgery

Boston - American Association for Thoracic Surgery

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

AMERICAN ASSOCIATION FOR THORACIC SURGERYF7. Biodegradable Synthetic Small-Calibre Vascular Grafts:Long-Term Results After Replacement of the Rat AortaBeat H. Walpoth, 1 Damiano Mugnai, 1 Jean-Christophe Tille, 2Francesco Innocente, 1 Benjamin Nottelet, 3 Corinne Berthonneche, 4Xavier Montet, 5 Sarra de Valence, 3 Michael Moeller, 3 Robert Gurny, 3Afksendiyos Kalangos 11. Department of Cardiovascular <strong>Surgery</strong>, University Hospital of Geneva, Geneva,Switzerland; 2. Department of Pathology, University Hospital of Geneva,Geneva, Switzerland; 3. Department of Pharmaceutics & BiopharmaceuticsEPGL, University of Geneva, Geneva, Switzerland; 4. Department of Medicine,University Hospital of Lausanne, Lausanne, Switzerland; 5. Department ofRadiology, University Hospital of Geneva, Geneva, SwitzerlandInvited Discussant: Gorav AilawadiOBJECTIVE: Shelf-ready synthetic small calibre grafts are needed <strong>for</strong> coronaryartery bypass grafting. Biodegradable scaffolds resistant to degradation-inducedaneurysm <strong>for</strong>mation in the systemic arterial circulation have been developed <strong>for</strong> invivo vascular tissue engineering. Our aim is to assess the long-term results of synthetic,biodegradable small-calibre vascular grafts compared to ePTFE <strong>for</strong> aorticreplacement in the rat model.TUESDAYMorningMETHODS: Ten anaesthetised Sprague Dawley rats (male, 275g), received aninfrarenal aortic graft (5 biodegradable; 5 ePTFE) replacement (end-to-end; 2 mmID; 20 mm long) and 5 rats served as shame controls. Biodegradable grafts (polycaprolactone= PCL) were produced by random nano-fibre (porosity 80%) electrospinning.After 1-year survival in vivo high resolution ultra-sonography (Visualsonics;see figure) and angiography were per<strong>for</strong>med to assess patency, stenosis,aneurysm <strong>for</strong>mation, intimal hyperplasia and compliance. After explantationmicro CT calcification quantification, histology, immuno-histology, scanning electronmicroscopy (SEM) and morphometry were carried out.RESULTS: All grafts (PCL and ePTFE) showed 100% patency at 12 months. Noaneurysmal dilation or stenoses were found in the PCL group by angiography.Ultra-sonography showed minimal peri-anastomotic intimal hyperplasia in PCL131

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!