Hubbell Wiring Device.pdf - Eversave Technology

Hubbell Wiring Device.pdf - Eversave Technology Hubbell Wiring Device.pdf - Eversave Technology

eversavetech.net
from eversavetech.net More from this publisher
12.07.2015 Views

GFCI Receptacles homeSELECT homeSELECT GFCI ReceptaclesSwitches and ReceptaclesSafety And Economy.UL Listed and CSA Certified.Meets UL943 performancerequirements.Recessed test andreset buttons to preventaccidental tripping fromoversized molded plugs.Reinforced contactsassure maximumplug retention.GF15ILGF20ILGFBF20ILGFSP15IGFCI ReceptaclesDescription Rating ColorGFCI Duplex Receptacle,Flush, Nylon Face,Back and Side Wire Terminations,Matching Nylon Wallplate IncludedGFCI Duplex Receptacle,Flush, Nylon Face,Back and Side Wire Terminations,Matching Nylon Wallplate IncludedCircuit Guard Faceless GFCI,Faceless,Back and Side Wire Terminations,Matching Nylon Wallplate IncludedSingle-Pole Switch,GFCI Grounding Receptacle,Back and Side Wire Terminations,Matching Nylon Wallplate Included10ka Short Circuit Current Rating15A 125VNEMA 5-15R20A 125VNEMA 5-20R20A 125V8.3A 1000W15A 125VNEMA 5-15RLarge, combination backand side wiring clamp-typeterminals accept up to#10 AWG wire.LED IndicatorFlashing red LEDsignals loss of GFCIprotection.Face and base molded ofa rugged impact-resistantthermoplastic material.AlmondBlackBrownGrayIvoryLight AlmondRedWhiteAlmondBlackBrownGrayIvoryLight AlmondRedWhiteAlmondBlackBrownGrayIvoryLight AlmondRedWhiteAlmondBlackBrownIvoryLight AlmondWhite* *RWRTamper-Resistant,Weather ResistantCatalog NumbersGFTR15ALGFTR15BKGFTR15GFTR15GYGFTR15IGFTR15LAGFTR15RGFTR15WGFTR20ALGFTR20BKGFTR20GFTR20GYGFTR20IGFTR20LAGFTR20RGFTR20W——————————————CharacteristicsTrip LevelTrip TimeFrequencyVoltageAmperageMaximum Interrupting CapacityOperating TemperatureMaximum HumidityListings & StandardsCodesStandardCatalog NumbersGF15ALL ΔGF15BKL ΔGF15L ΔGF15GYL ΔGF15IL ΔGF15LAL ΔGF15RL ΔGF15WL ΔGF20ALL ΔGF20BKL ΔGF20L ΔGF20GYL ΔGF20IL ΔGF20LAL ΔGF20RL ΔGF20WL ΔGFBF20ALL ΔGFBF20BKL ΔGFBF20L ΔGFBF20GYL ΔGFBF20IL ΔGFBF20LAL ΔGFBF20RL ΔGFBF20WL ΔGFSP15ALGFSP15BKGFSP15GFSP15IGFSP15LAGFSP15WNotes: Δ To be replaced by Auto Grounding version in the 4th quarter 2008. Add a “A” suffix for Auto Grounding catalognumbers. See section H for more information.* Refer to Technical Section X, page X-8 for TR and WR descriptions.V-24 www.hubbell-wiring.comDimensions in Inches (mm)

homeSELECT Self Test GFCI ReceptaclesSwitches and ReceptaclesSafety, Plus More.The only GFCI receptacle that tests itself. Every 60 seconds the device performs a diagnostic teston its circuitry, offering a comprehensive approach to testing. Reverse wire safety feature assuresunit cannot be reset under a reversed wiring condition. Meets UL943 performance requirements.Rating4 to 6 mA..025 sec. nominal60 Hz.120V AC +10% - 15%15A/20A, 20A Feed Thru10,000A-35°C to +66°C or-30°F to +150°F95%Meets UL498 for receptacles,UL943 for GFCIsUL File E41978, CSA CertifiedMeets all NEC ® & CEC requirementsSelf Test GFCI ReceptaclesUL Listed and CSA Certified.Power IndicatorSteady ON green LEDindicates powersupplied to device.No power to facewhen reverse wired,meets UL 943requirement.High impactchemical resistantnylon housing.Description Rating Color Catalog NumbersSelf Test GFCI Duplex Receptacle,Flush, Nylon Face,Back and Side Wire Terminations,Matching Nylon Wallplate IncludedSelf Test GFCI Duplex Receptacle,Flush, Nylon Face,Back and Side Wire Terminations,Matching Nylon Wallplate IncludedSelf Test Circuit Guard Faceless GFCI,Faceless,Back and Side Wire Terminations,Matching Nylon Wallplate Included15A 125VNEMA 5-15R20A 125VNEMA 5-20R20A 125V10ka Short Circuit Current RatingAlmondBlackBrownGrayIvoryLight AlmondRedWhiteAlmondBlackBrownGrayIvoryLight AlmondRedWhiteAlmondBlackBrownGrayIvoryLight AlmondRedWhiteGFST15ALGFST15BKGFST15GFST15GYGFST15IGFST15LAGFST15RGFST15WGFST20ALGFST20BKGFST20GFST20GYGFST20IGFST20LAGFST20RGFST20WGFSTBF20ALGFSTBF20BKGFSTBF20GFSTBF20GYGFSTBF20IGFSTBF20LAGFSTBF20RGFSTBF20WGFCI IndicatorFlashing red LEDsignals loss of GFCIprotection.Steady ON red LEDsignals ground faultcondition.10,000 Ampshort circuitwithstand rating.GFST15IGFST20IGFSTBF20IhomeSELECT Self Test GFCI ReceptaclesDimensions in Inches (mm)www.hubbell-wiring.comV-25

GFCI Receptacles homeSELECT homeSELECT GFCI ReceptaclesSwitches and ReceptaclesSafety And Economy.UL Listed and CSA Certified.Meets UL943 performancerequirements.Recessed test andreset buttons to preventaccidental tripping fromoversized molded plugs.Reinforced contactsassure maximumplug retention.GF15ILGF20ILGFBF20ILGFSP15IGFCI ReceptaclesDescription Rating ColorGFCI Duplex Receptacle,Flush, Nylon Face,Back and Side Wire Terminations,Matching Nylon Wallplate IncludedGFCI Duplex Receptacle,Flush, Nylon Face,Back and Side Wire Terminations,Matching Nylon Wallplate IncludedCircuit Guard Faceless GFCI,Faceless,Back and Side Wire Terminations,Matching Nylon Wallplate IncludedSingle-Pole Switch,GFCI Grounding Receptacle,Back and Side Wire Terminations,Matching Nylon Wallplate Included10ka Short Circuit Current Rating15A 125VNEMA 5-15R20A 125VNEMA 5-20R20A 125V8.3A 1000W15A 125VNEMA 5-15RLarge, combination backand side wiring clamp-typeterminals accept up to#10 AWG wire.LED IndicatorFlashing red LEDsignals loss of GFCIprotection.Face and base molded ofa rugged impact-resistantthermoplastic material.AlmondBlackBrownGrayIvoryLight AlmondRedWhiteAlmondBlackBrownGrayIvoryLight AlmondRedWhiteAlmondBlackBrownGrayIvoryLight AlmondRedWhiteAlmondBlackBrownIvoryLight AlmondWhite* *RWRTamper-Resistant,Weather ResistantCatalog NumbersGFTR15ALGFTR15BKGFTR15GFTR15GYGFTR15IGFTR15LAGFTR15RGFTR15WGFTR20ALGFTR20BKGFTR20GFTR20GYGFTR20IGFTR20LAGFTR20RGFTR20W——————————————CharacteristicsTrip LevelTrip TimeFrequencyVoltageAmperageMaximum Interrupting CapacityOperating TemperatureMaximum HumidityListings & StandardsCodesStandardCatalog NumbersGF15ALL ΔGF15BKL ΔGF15L ΔGF15GYL ΔGF15IL ΔGF15LAL ΔGF15RL ΔGF15WL ΔGF20ALL ΔGF20BKL ΔGF20L ΔGF20GYL ΔGF20IL ΔGF20LAL ΔGF20RL ΔGF20WL ΔGFBF20ALL ΔGFBF20BKL ΔGFBF20L ΔGFBF20GYL ΔGFBF20IL ΔGFBF20LAL ΔGFBF20RL ΔGFBF20WL ΔGFSP15ALGFSP15BKGFSP15GFSP15IGFSP15LAGFSP15WNotes: Δ To be replaced by Auto Grounding version in the 4th quarter 2008. Add a “A” suffix for Auto Grounding catalognumbers. See section H for more information.* Refer to Technical Section X, page X-8 for TR and WR descriptions.V-24 www.hubbell-wiring.comDimensions in Inches (mm)

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!