Hubbell Wiring Device.pdf - Eversave Technology

Hubbell Wiring Device.pdf - Eversave Technology Hubbell Wiring Device.pdf - Eversave Technology

eversavetech.net
from eversavetech.net More from this publisher
12.07.2015 Views

PG and Metric Threaded Deluxe Cord Grips Kellems ® Wire Management ProductsKellems ® Wire Management ProductsPG and Metric Threaded Deluxe Cord GripsAluminum Fittings, Stainless Steel Mesh, Liquidtight, for Insulated CablesWARNING!It is important that you readall breaking strength, safetyand technical data relatingto this product on pagesT-71 through T-76.Straight PG MaleStraight Metric MaleNote: *Cable jacket may have to bestripped to pass through connectorbody. Kellems ® Deluxe Cord Gripsare suitable for use in hazardouslocations per Class I Div. 2, ClassII Div. 1 & 2, Class III Div. 1 & 2 ofthe National Electric Code Sections501.10(b)(2), 502.10(a)(2), 502.10(b)(2), 503.10(a)(2) and 503.10(b).Straight PG* Male ThreadCord Diameter RangeInches (cm) Hub Size Catalog Numbers.500"-.625" (1.27-1.59) PG16 074PG16010.500"-.625" (1.27-1.59) PG21 074PG21010.625"-.750" (1.59-1.90) PG21 074PG211247.750"-.875" (1.90-2.22) PG21 074PG211248.625"-.750" (1.59-1.90) PG29 074PG29021.750"-.875" (1.90-2.22) PG29 074PG29023.875"-1.000" (2.22-2.54) PG29 074PG290251.125"-1.250" (2.86-3.17) PG29 074PG291028**1.125"-1.250" (2.86-3.17) PG36 074PG36028*** Panzergewinde**Cable jacket may have to be stripped to pass through connector body.Straight Metric Male ThreadCord Diameter RangeInches (cm) Form Size Catalog Numbers.500"-.625" (1.27-1.59) F2 074M20010.625"-.750" (1.59-1.90) F3 074M251247.750"-.875" (1.90-2.22) F3 074M251248.625"-.750" (1.59-1.90) F2 074M25017.750"-.875" (1.90-2.22) F4 074M32021.875"-1.000" (2.22-2.54) F4 074M320231.125"-1.250" (2.86-3.17) F4 074M320251.125"-1.250" (2.86-3.17) F5 074M3210281.125"-1.250" (2.86-3.17) F5 074M321250SpecificationsMaterialTemperature RangeAluminum–30°F to +240°F (–34°C to +115°C).Stainless Steel (Gotcha Rings) –30°F to +240°F (–34°C to +115°C).Neoprene (Bushings)–30°F to +240°F (–34°C to +115°C).Hazardous Locations Suitable for use in hazardous locations per Class I Div. 2,Class II Div. 1 & 2, Class III Div. 1 & 2 N.E.C.Reference 501.10(b)(2), 502.10(a)(2), 502.10(b)(2), 503.10(a)(2)and 503.10(b).ApprovalsCord Connectors UL Listed in accordance with Standard 514B.Deluxe Cord Grips UL Control numbers 898D and 899D.Wet LocationsSuitable for use in wet locations when used with a listed nylonwasher between box and fitting.When used with a metal clad o-ring, product has UL 4Xenvironmental rating.T-64 www.hubbell-wiring.comDimensions in Inches (mm)

Kellems ® Wire Management ProductsDust-Tight Strain Relief GripsAluminum Fittings, Galvanized Steel Mesh, for Insulated CablesNon-Insulated, Wide Range Strain ReliefCableMesh LengthDiameter Range Thread @ Nom. Dia. CatalogInches (cm) Size Inches (cm) Numbers.24"-.32" (.61-.81) ½ N.P.T. 3.25" (8.25) 073031200.32"-.43" (.81-1.09) ½ N.P.T. 3.75" (9.52) 073031201.43"-.54" (1.09-1.37) ½ N.P.T. 4.75" (12.06) 073031202.54"-.73" (1.37-1.85) ¾ N.P.T. 6.5" (16.51) 073031203.73"-.97" (1.85-2.46) 1 N.P.T. 7" (17.78) 073031204.97"-1.25" (2.46-3.17) 1¼ N.P.T. 9" (22.86) 073031205.73"-.97" (1.85-2.46) PG29* 7" (17.78) 073PG291204* PanzergewindeInsulated, Wide Range Strain Relief with Insulating BushingMeshMin. SpaceCable Length @ BetweenDiameter Range Thread Nom. Dia. Dim. A Grips CatalogInches (cm) Size Inches (cm) In. (cm) In. (cm) Numbers.24"-.32" (.61-.81) ½ N.P.S. 3.25" (8.25) 1" (2.54) 1.25" (3.17) 073031206.32"-.43" (.81-1.09) ½ N.P.S. 3.75" (9.52) 1" (2.54) 1.25" (3.17) 073031207.43"-.54" (1.09-1.37) ½ N.P.S. 4.75" (12.06) 1" (2.54) 1.25" (3.17) 073031208.54"-.73" (1.37-1.85) ¾ N.P.S. 6.5" (16.51) 1" (2.54) 1.5" (3.81) 073031209.73"-.97" (1.85-2.46) 1 N.P.S. 7" (17.78) 1.313" (3.02) 1.75" (4.44) 073031210.97"-1.25" (2.46-3.17) 1¼ N.P.S. 9" (22.86) 1.313" (3.02) 2.25" (5.71) 0730312111.25"-1.50" (3.17-3.81) 1½ N.P.T. 11.75" (29.84) 1.313" (3.02) 2.5" (6.35) 0730312121.50"-1.70" (3.81-4.32) 2 N.P.T. 13.25" (33.65) 1.375" (3.49) 3.25" (8.25) 0730312131.70"-2.00" (4.32-5.08) 2½ N.P.T. 13.5" (34.29) 1.5" (3.81) 3.625" (9.21) 0730312142.00"-2.45" (5.08-6.22) 2½ N.P.T. 13.75" (34.92) 1.5" (3.81) 3.625" (9.21) 073031215WARNING!It is important that you readall breaking strength, safetyand technical data relatingto this product on pagesT-71 through T-76.Non-InsulatedInsulatedKellems ® Wire Management Products Dust-Tight Strain Relief GripsDimensions in Inches (mm)www.hubbell-wiring.comT-65

PG and Metric Threaded Deluxe Cord Grips Kellems ® Wire Management ProductsKellems ® Wire Management ProductsPG and Metric Threaded Deluxe Cord GripsAluminum Fittings, Stainless Steel Mesh, Liquidtight, for Insulated CablesWARNING!It is important that you readall breaking strength, safetyand technical data relatingto this product on pagesT-71 through T-76.Straight PG MaleStraight Metric MaleNote: *Cable jacket may have to bestripped to pass through connectorbody. Kellems ® Deluxe Cord Gripsare suitable for use in hazardouslocations per Class I Div. 2, ClassII Div. 1 & 2, Class III Div. 1 & 2 ofthe National Electric Code Sections501.10(b)(2), 502.10(a)(2), 502.10(b)(2), 503.10(a)(2) and 503.10(b).Straight PG* Male ThreadCord Diameter RangeInches (cm) Hub Size Catalog Numbers.500"-.625" (1.27-1.59) PG16 074PG16010.500"-.625" (1.27-1.59) PG21 074PG21010.625"-.750" (1.59-1.90) PG21 074PG211247.750"-.875" (1.90-2.22) PG21 074PG211248.625"-.750" (1.59-1.90) PG29 074PG29021.750"-.875" (1.90-2.22) PG29 074PG29023.875"-1.000" (2.22-2.54) PG29 074PG290251.125"-1.250" (2.86-3.17) PG29 074PG291028**1.125"-1.250" (2.86-3.17) PG36 074PG36028*** Panzergewinde**Cable jacket may have to be stripped to pass through connector body.Straight Metric Male ThreadCord Diameter RangeInches (cm) Form Size Catalog Numbers.500"-.625" (1.27-1.59) F2 074M20010.625"-.750" (1.59-1.90) F3 074M251247.750"-.875" (1.90-2.22) F3 074M251248.625"-.750" (1.59-1.90) F2 074M25017.750"-.875" (1.90-2.22) F4 074M32021.875"-1.000" (2.22-2.54) F4 074M320231.125"-1.250" (2.86-3.17) F4 074M320251.125"-1.250" (2.86-3.17) F5 074M3210281.125"-1.250" (2.86-3.17) F5 074M321250SpecificationsMaterialTemperature RangeAluminum–30°F to +240°F (–34°C to +115°C).Stainless Steel (Gotcha Rings) –30°F to +240°F (–34°C to +115°C).Neoprene (Bushings)–30°F to +240°F (–34°C to +115°C).Hazardous Locations Suitable for use in hazardous locations per Class I Div. 2,Class II Div. 1 & 2, Class III Div. 1 & 2 N.E.C.Reference 501.10(b)(2), 502.10(a)(2), 502.10(b)(2), 503.10(a)(2)and 503.10(b).ApprovalsCord Connectors UL Listed in accordance with Standard 514B.Deluxe Cord Grips UL Control numbers 898D and 899D.Wet LocationsSuitable for use in wet locations when used with a listed nylonwasher between box and fitting.When used with a metal clad o-ring, product has UL 4Xenvironmental rating.T-64 www.hubbell-wiring.comDimensions in Inches (mm)

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!