Hubbell Wiring Device.pdf - Eversave Technology

Hubbell Wiring Device.pdf - Eversave Technology Hubbell Wiring Device.pdf - Eversave Technology

eversavetech.net
from eversavetech.net More from this publisher
12.07.2015 Views

Painted Pedestal FRPT – 2- and 3-Inch Core Hole Two-Piece Units Fire-Rated Poke-ThroughsFire-Rated Poke-ThroughsPainted Pedestal FRPT2- and 3-Inch Core Hole Two-Piece UnitsPainted Pedestal FRPT3-Inch Core Hole Two-Piece UnitComplies with UL514AThrough-Floor FittingThrough-Floor FittingCatalog NumberCatalog NumberPT7XC Large Capacity Multi-Service PT27A Multi-Service PedestalPedestal Through Floor FittingThrough Floor FittingThrough floor fitting with (1) 1¼ in. E.M.T.Through floor fitting with (1) ¾ in. E.M.T.stem for low voltage and (1) ½ in. E.M.T.stem for low voltage and (1) ½ in. E.M.T.stem for power applications.stem for power applications.Specifications:Specifications: UL Listed and CSA Certified. UL Listed and CSA Certified. 1 – 4 hour fire rating (1 – 3 hour for steel 1 – 4 hour fire rating (1 – 3 hour for steelfloor units and concrete topping,floor units and concrete topping,D900 Series Design).D900 Series Design). For 2¼ to 7 in. floor thickness. For 2¼ to 7 in. floor thickness. UL installation spacing. Minimum 2 ft. UL installation spacing. Minimum 2 ft.on center and not more than 1 peron center and not more than 1 per65 sq. ft. of floor area. 65 sq. ft. of floor area. Approved for use in the City of Chicago.PT7XC Approved for use in the City of Chicago.PT27ANote: See page M-26 for technical information.Note: See page M-26 for technical information.Pedestal Service Fittings (Order 1 plate per gang)2-Gang Catalog Numbers 4-Gang Catalog Numbers 6-Gang Catalog NumbersFR280ALA Aluminum Finish FR480BKA Black FR680BKA BlackFR280BKA Black FR480GYA Gray FR680GYA GrayFR280GYA GrayUse with PT27A only. Use with PT27A or PT7XC. Use with PT27A or PT7XC. Painted aluminum housing with low voltage barrier(s). Plates and devices sold separately. For additional barriers, use catalog number FRBR1 (see page M-13). UL Listed and CSA Certified.Note: See page M-25 for technical information.Painted Pedestal FRPT2-Inch Core Hole Two-Piece UnitFR280BKA FR480GYA FR680BKAPedestal Face Plates (Order 1 plate per gang)Catalog NumbersCatalog NumbersSS2309DBKA Black Duplex SS2309FBKA Black Furniture FeedSS2309DGYA Gray SS2309FGYA Gray (¾ in. KO)SS2309FALA Aluminum FinishSS2309SLBKA Black Style Line ® / SS2309F1BKA Black Furniture FeedSS2309SLGYA Gray GFCI SS2309F1GYA Gray (1 in. KO)SS2309SBKA Black Single Rec. SS2309TBKA Black Bushed DataSS2309SGYA Gray (1.39 in. OD) SS2309TGYA Gray Opening (1 in. ID)SS2309BBKA Black BlankSS2309BGYA GraySS2309BALA Aluminum Finish Painted aluminum plates. UL Listed and CSA Certified.M-12 www.hubbell-wiring.comDimensions in Inches (mm)

Fire-Rated Poke-ThroughsBrushed Aluminum Pedestal FRPT3-Inch Core Hole Two-Piece UnitThrough-Floor FittingPedestal Service FittingComplies with UL514ACatalog NumbersCatalog NumberPT7XC Large Capacity Multi-Service FR80AL Brushed Aluminum 2-Gang PedestalPedestal Through-Floor FittingService FittingThrough floor fitting with (1) 1¼ in. E.M.T.For use with PT7XC only.stem for low voltage and (1) ½ in. E.M.T.stem for power applications.Specifications: UL Listed and CSA Certified. Brushed aluminum housing 1 – 4 hour fire rating (1 – 3 hour for steelwith low voltage barrier. Platesfloor units and concrete topping,and devices sold separately.D900 Series Design). UL Listed and CSA Certified. For 2¼ to 7 in. floor thickness. UL installation spacing. Minimum 2 ft.on center and not more than 1 per65 sq. ft. of floor area. Approved for use in the City of Chicago. PT7XCNote: See page M-26 for technical information.FR80ALNote: See page M-25 for technical information.PlatesCatalog NumbersCatalog NumbersSS309D Duplex SS309T Bushed DataOpening (1 in. ID)SS309S Single Rec. SS309SF* Furniture Feed(1.39 in. OD) (¾ in. KO)SS309B Blank SS309BF* Furniture FeedBlank*For furniture feed applications usingSS309SF, a SS309BF blank must beSS309DS Style Line/GFCI used for 2nd plate.3" Core Hole FRPT Accessories 302/304 Stainless steel plates(SS309SF & SS309BF are aluminum). UL Listed and CSA Certified.Catalog NumbersCatalog NumbersFRP250 Gray Closure Plug EXT13 PT7XC Extension KitTextured aluminum plug seals 3 in. core holeExtends PT7XC FRPT to accommodatewhen FRPT is no longer required and isbetween 7 in. and 13 in. floor thickness.removed. Maintains the floor’s 1 – 4 hourfire rating. UL Listed and CSA Certified.AP2GY Gray Flush FRPT AP22 2-Gang Gray Pedestal FRPTAP2I Ivory Abandonment Plate AP42 4-Gang Gray Abandonment PlateUse with PT7FSD, PT73SD or PT71SD only.Use with PT27A or PT7XC Only. Covers theCovers the opening when FRPT is abandoned.opening when FRPT is abandoned. ServiceService fitting is removed and through-floorfitting is removed and through-floor fittingfitting remains.remains.FF3GY Gray Multi-Service Furniture Feed FRBR1 Low Voltage BarrierFF3I Ivory Replacement InsertsUse as a replacement cover for PT73FFSDUse with FR280, FR480, and FR680series, or to convert installed PT7FSD seriespedestal service fittings only wheninto furniture feed FRPTs. Includes (2) ½ in.additional power/low voltagethreaded hubs for low voltage and (1) ¾ in.separation is required.threaded hub for power. (UL Listed only.)Fire-Rated Poke-Throughs Brushed Aluminum Pedestal FRPT – 3-Inch Core Hole Two-Piece UnitDimensions in Inches (mm)www.hubbell-wiring.comM-13

Fire-Rated Poke-ThroughsBrushed Aluminum Pedestal FRPT3-Inch Core Hole Two-Piece UnitThrough-Floor FittingPedestal Service FittingComplies with UL514ACatalog NumbersCatalog NumberPT7XC Large Capacity Multi-Service FR80AL Brushed Aluminum 2-Gang PedestalPedestal Through-Floor FittingService FittingThrough floor fitting with (1) 1¼ in. E.M.T.For use with PT7XC only.stem for low voltage and (1) ½ in. E.M.T.stem for power applications.Specifications: UL Listed and CSA Certified. Brushed aluminum housing 1 – 4 hour fire rating (1 – 3 hour for steelwith low voltage barrier. Platesfloor units and concrete topping,and devices sold separately.D900 Series Design). UL Listed and CSA Certified. For 2¼ to 7 in. floor thickness. UL installation spacing. Minimum 2 ft.on center and not more than 1 per65 sq. ft. of floor area. Approved for use in the City of Chicago. PT7XCNote: See page M-26 for technical information.FR80ALNote: See page M-25 for technical information.PlatesCatalog NumbersCatalog NumbersSS309D Duplex SS309T Bushed DataOpening (1 in. ID)SS309S Single Rec. SS309SF* Furniture Feed(1.39 in. OD) (¾ in. KO)SS309B Blank SS309BF* Furniture FeedBlank*For furniture feed applications usingSS309SF, a SS309BF blank must beSS309DS Style Line/GFCI used for 2nd plate.3" Core Hole FRPT Accessories 302/304 Stainless steel plates(SS309SF & SS309BF are aluminum). UL Listed and CSA Certified.Catalog NumbersCatalog NumbersFRP250 Gray Closure Plug EXT13 PT7XC Extension KitTextured aluminum plug seals 3 in. core holeExtends PT7XC FRPT to accommodatewhen FRPT is no longer required and isbetween 7 in. and 13 in. floor thickness.removed. Maintains the floor’s 1 – 4 hourfire rating. UL Listed and CSA Certified.AP2GY Gray Flush FRPT AP22 2-Gang Gray Pedestal FRPTAP2I Ivory Abandonment Plate AP42 4-Gang Gray Abandonment PlateUse with PT7FSD, PT73SD or PT71SD only.Use with PT27A or PT7XC Only. Covers theCovers the opening when FRPT is abandoned.opening when FRPT is abandoned. ServiceService fitting is removed and through-floorfitting is removed and through-floor fittingfitting remains.remains.FF3GY Gray Multi-Service Furniture Feed FRBR1 Low Voltage BarrierFF3I Ivory Replacement InsertsUse as a replacement cover for PT73FFSDUse with FR280, FR480, and FR680series, or to convert installed PT7FSD seriespedestal service fittings only wheninto furniture feed FRPTs. Includes (2) ½ in.additional power/low voltagethreaded hubs for low voltage and (1) ¾ in.separation is required.threaded hub for power. (UL Listed only.)Fire-Rated Poke-Throughs Brushed Aluminum Pedestal FRPT – 3-Inch Core Hole Two-Piece UnitDimensions in Inches (mm)www.hubbell-wiring.comM-13

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!