Heavy Duty GFCI Receptacles with Auto Grounding Hospital ProductsHospital ProductsHeavy Duty GFCI Receptacles with Auto Grounding15 and 20 Ampere, 125 Volts AC2 Pole, 3 Wire GroundingGFR8200HOWLGFR8200HOWLAHospital GradeCircuit Guard ® GFCI ReceptaclesDescription Rating Color Catalog NumbersFlush, nylon face,back and side wired,multiple drive screws.Hospital GradeCircuit Guard ® GFCI ReceptaclesDescription Rating Color Catalog NumbersFlush, nylon face,back and side wired,multiple drive screws,automatic groundingclip.15 and 20A125V AC15 and 20A125V AC10ka Short Circuit Current RatingComprehensive diagnostics.• When test button is actuated, both theelectronic components and mechanicaltrip mechanism are functionally tested.Ground fault indicator.• Flashing RED indicates device has lostcapability to provide protection.No power at face if reverse wired.• Open circuit condition eliminates falseassumption of protection at face.Visible Termination.• External bundling clamp.15A 125VNEMA 5-15RAlmond GFR8200HALL GFR8300HALLBlack GFR8200HBKL GFR8300HBKLBrown GFR8200HL GFR8300HLGray GFR8200HGYL GFR8300HGYLIvory GFR8200HIL GFR8300HILOffice White GFR8200HOWL GFR8300HOWLRed GFR8200HRL GFR8300HRLWhite GFR8200HWL GFR8300HWL10ka Short Circuit Current RatingComprehensive diagnostics.• When test button is actuated, both theelectronic components and mechanicaltrip mechanism are functionally tested.Ground fault indicator.• Flashing RED indicates device has lostcapability to provide protection.No power at face if reverse wired.• Open circuit condition eliminates falseassumption of protection at face.Installation ease.• Internal back wiring.• Automatic grounding clip.• Captive mounting screws.15A 125VNEMA 5-15R20A 125VNEMA 5-20R20A 125VNEMA 5-20RAlmond GFR8200HALLA GFR8300HALLABlack GFR8200HBKLA GFR8300HBKLABrown GFR8200HLA GFR8300HLAGray GFR8200HGYLA GFR8300HGYLAIvory GFR8200HILA GFR8300HILAOffice White GFR8200HOWLA GFR8300HOWLARed GFR8200HRLA GFR8300HRLAWhite GFR8200HWLA GFR8300HWLANotes: GFCI type receptacles should not be used in critical care patient areas or for electrical life supportequipment applications because of the possibility of power interruption. All GFCI receptacles listedabove are furnished with a matching color nylon wallplate. 20 amp feedthrough capability.I-10 www.hubbell-wiring.comDimensions in Inches (mm)

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!