12.07.2015 Views

Hubbell Wiring Device.pdf - Eversave Technology

Hubbell Wiring Device.pdf - Eversave Technology

Hubbell Wiring Device.pdf - Eversave Technology

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Ground Fault ProductsHeavy Duty Tamper-Resistant and Self TestGFCI Receptacles15 and 20 Ampere, 125 Volts AC2 Pole, 3 Wire GroundingCircuit Guard ® GFCI ReceptaclesTamper-Resistant, Weather Resistant15A 125VNEMA 5-15RDescription Rating Color Catalog NumbersHospital GradeFlush, polyester face,back and side wired,multiple drive screws,automatic groundingclip.Hospital GradeAUTOGUARD Self Test, GFCI Receptacles15A 125VNEMA 5-15RDescription Rating Color Catalog NumbersFlush, nylon face,back and side wired,multiple drive screws.15 and 20A125V AC15 and 20A125V AC20A 125VNEMA 5-20RAlmond GFR8200HALTR GFR8300HALTRBlack GFR8200HBKTR GFR8300HBKTRBrown GFR8200HTR GFR8300HTRGray GFR8200HGYTR GFR8300HGYTRIvory GFR8200HITR GFR8300HITRLight Almond GFR8200HLATR GFR8300HLATROffice White GFR8200HOWTR GFR8300HOWTRRed GFR8200HRTR GFR8300HRTRWhite GFR8200HWTR GFR8300HWTR20A 125VNEMA 5-20RAlmond GFR8200HALST GFR8300HALSTBlack GFR8200HBKST GFR8300HBKSTBrown GFR8200HST GFR8300HSTGray GFR8200HGYST GFR8300HGYSTIvory GFR8200HIST GFR8300HISTOffice White GFR8200HOWST GFR8300HOWSTRed GFR8200HRST GFR8300HRSTWhite GFR8200HWST GFR8300HWSTNotes: GFCI type receptacles should not be used in critical care patient areas or for electrical life supportequipment applications because of the possibility of power interruption. All GFCI receptacles listedabove are furnished with a matching color nylon wallplate. 20 amp feedthrough capability.* Refer to Technical Section X, page X-8 for TR and WR descriptions.Limits improper access to energized contacts.• Patented tamper-resistant protection.No power at face if reverse wired.• Open circuit condition eliminates falseassumption of protection at face.Ground fault indicator.• Flashing RED indicates device has lostcapability to provide protection.Accepts fork terminals.• Open terminal design.Installation ease.• Internal back wiring.• Automatic grounding feature.• Captive mounting screws.*WRGFR8300HITR10ka Short Circuit Current RatingContinually tests and monitors forpeople protection automatically.• Patented self test diagnostics.*Meets July 28, 2006UL Standard 943Class A GFCI10ka Short Circuit Current RatingPower indication• Steady “ON” GREEN LED providesindication of power.Ground fault indicator• Steady “ON” RED LED provides visualindication of a ground fault condition.Flashing red indicates device has lostcapability to provide protection.No power at face if reverse wired.• Open circuit condition eliminates falseassumption of protection at face.GFR8200HWSTHospital Products Heavy Duty Tamper-Resistant and Self Test GFCI ReceptaclesDimensions in Inches (mm)www.hubbell-wiring.comI-9

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!