12.07.2015 Views

Hubbell Wiring Device.pdf - Eversave Technology

Hubbell Wiring Device.pdf - Eversave Technology

Hubbell Wiring Device.pdf - Eversave Technology

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Extra Heavy Duty Tamper-Resistant GFCI Receptacles Hospital ProductsHospital ProductsExtra Heavy Duty Tamper-Resistant GFCI Receptacles15 and 20 Ampere, 125 Volts AC2 Pole, 3 Wire GroundingGFR8300SGIGFR8300ITRWR***TR*WRAUTOGUARD Self Test GFCI ReceptaclesTamper-Resistant, Weather ResistantDescription Rating Color Catalog NumbersHospital GradeFlush, polyester face,back and side wired,multiple drive screws.CircuitGuard ® GFCI ReceptaclesTamper-Resistant, Weather ResistantDescription Rating Color Catalog NumbersHospital GradeFlush, polyester face,back and side wired,multiple drive screws.15 and 20A125V AC15 and 20A125V AC10ka Short Circuit Current RatingLimits improper access to energized contacts.• Patented tamper-resistant protection.Continually tests and monitors for peopleprotection automatically.• Patented self test diagnostics.Power indication.• Steady "ON" GREEN LED providesindication of power.Ground fault indicator.• Steady “ON” RED LED provides visualindication of a ground fault condition.Flashing red indicates device has lostcapability to provide protection.No power at face if reverse wired.• Open circuit condition eliminates falseassumption of protection at face.Durable face with V-0 flammability rating.• Polyester face cover.15A 125VNEMA 5-15RBlack GFR8200SGBK GFR8300SGBKBrown GFR8200SG GFR8300SGGray GFR8200SGGY GFR8300SGGYIvory GFR8200SGI GFR8300SGIRed GFR8200SGR GFR8300SGRWhite GFR8200SGW GFR8300SGW15A 125VNEMA 5-15R20A 125VNEMA 5-20R20A 125VNEMA 5-20RBlack GFR8200BKTR GFR8300BKTRBrown GFR8200TR GFR8300TRGray GFR8200GYTR GFR8300GYTRIvory GFR8200ITR GFR8300ITRRed GFR8200RTR GFR8300RTRWhite GFR8200WTR GFR8300WTRMeets July 28, 2006UL Standard 943Class A GFCINotes: GFCI type receptacles should not be used in critical care patient areas or for electrical life supportequipment applications because of the possibility of power interruption. All GFCI receptacles listedabove are furnished with both a matching color nylon wallplate, and a SS26 302/304 super stainlesssteel wallplate. 20 amp feedthrough capability.* Refer to Technical Section X, page X-8 for TR and WR descriptions.I-8 www.hubbell-wiring.comDimensions in Inches (mm)

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!